An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Welcome page No. 1 for gas safety equipment and gas control equipment LEAK-MASTER Leak_master_praes_uk_30722

  2. security for packaging features LEAK-MASTER • Micro-leak detection system for packages based on CO2 • non destructive detection even of smallest leaks • no need for costly Helium • minimal response time • quick product change • for flexible and rigid packages • no calibration required

  3. features security for packaging LEAK-MASTER • operator friendly - data and process parameter entry by means of touch screen or keyboard • easy-to-use intuitive system - no special skills required • convenient data administration and evaluation for customer oriented quality documentation • various chamber sizes • independent from CO2-levels in the ambient air • easy installation and start-up • stainless steel cabinet (chamber and PC) • features WITT Leak-LOGGER administration • of up to 99 users and 9,999 products

  4. screens security for packaging LEAK-MASTER OXYBABY  V LEAK MASTER WITT- LOGGER • start screen • please select the user • please enter the user • password for authorisation

  5. products security for packaging LEAK-MASTER OXYBABY  V • Product administration • leak level • measurement time • vacuum in mbar • need to be set by the • administrator before testing • please see the instruction manual for an exact explanation

  6. login security for packaging LEAK-MASTER OXYBABY  V User selection with the user selection each user can log in individually. User Identification is a very important security feature. User selection is made safe by the entering the personalised password

  7. product search security for packaging LEAK-MASTER OXYBABY  V • Product Selection • Once the user has identified himself the next step is to choose the product to be tested. That can be done very conveniently either per • touch screen, • mouse click or • keyboard

  8. testing security for packaging LEAK-MASTER OXYBABY  V Measurement Status Turning the LEAK-MASTER on there is a short warm-up phase. Also between two measurements a brief moment of readjustment is required. The measurement status is always shown automatically.Wait till the unit is ready for testing.

  9. insert security for packaging LEAK-MASTER OXYBABY  V • Preparation for testing • after the unit has indicated it is ready for testing, the sample is placed in the chamber • according to the size of the sample the chamber´s volume can be adapted (blocks)

  10. testing security for packaging LEAK-MASTER OXYBABY  V Testing • close the lid • push lid lightly • place the lever on top > the unit creates a vacuum, and shows the results on the monitor after the predefined time

  11. results security for packaging LEAK-MASTER OXYBABY  V Test results after the measurement time the result is shown on the monitor status of measurement status of measurement time

  12. product admin security for packaging LEAK-MASTER OXYBABY  V Product administration All data regarding the tested products may be exported or simply be printed using a standard printer Product administration also allows to conveniently add, delete or even search stored product data

  13. docu security for packaging LEAK-MASTER OXYBABY  V Data documentation Test result may again be exported for further evaluation (e.g with Excel) or simply be printed using a standard printer all recorded data

  14. key facts summary quickerresults smallest packages easy operation no calibrationrequired securehandling LEAKMASTER 1.     quick results – saving time and money 2.     variable analysis of various package sizes – only one unit for all packages It is also possible, for example, to check 2 packages in one test run 3.     memory for 9999 test results, with 99 users 4.     comfortable data interface to printer or PC – no manual data documentation needed - saves costly time 5. easy, professional and tamper proof administration of data for e.g. Quality Control 6.     stationary use - also available with trolly on request 7.     multilingual graphic display for true type text – minimal training, no special skills required 8. robust housing made of stainless steel - applicable for food and easy to clean 9. chamber size can be made to customers wishes 10. Standard power supply: 230VAC u. 380 VAC, other on request 11. No calibration of the CO2-Sensor necessary, easy operation 12. Control via industry PC with touch screen (optional with keyboard and mouse) 13. attractive unit package

  15. more information security for packaging LEAK-MASTER OXYBABY  V for more information please click here: technical data

  16. thank you Thank you ! www.wittgas.com