Honeywell Spyder™ Programmable Controllers. Spyder Controllers. Honeywell’s Spyder controllers. The power and flexibility of a plant controller inside the compact package of a unitary controller. Spyder BACnet. Spyder Offers More Features to Solve
E N D
Spyder Controllers Honeywell’s Spyder controllers • The power and flexibility of a plant controller inside the compact package of a unitary controller
Spyder BACnet Spyder Offers More Features to Solve Today’s Problems • Sylk Bus for TR70 and other future Sylk Devices • Fully Programmable • Removable Terminal Strips • Color Coded Terminals • Internal Real-Time Clock • Internal DC Power Supply • VAV with Integrated Actuator
Programming Tool • Industry’s First Unified Tool • Automatically convert your Lon applications to BACnet • Same programming environment for Lon and BACnet
Spyder VAV Controllers with Actuator * = L for Lon, B for BACnet MS/TP • 2 Digital Outputs reserved for Integrated Actuator • Integrated Pressure Sensor
Spyder VAV Controller w/o Actuator * = L for Lon, B for BACnet MS/TP • Integrated Pressure Sensor
Spyder Unitary Controller * = L for Lon, B for BACnet MS/TP • Extended Temperature Rating
Controller Architecture Communication bus (Lon or BACnet MS/TP) Programmable Unitary Controllers Programmable VAV Controllers with Actuator Programmable VAV Controllers w/o Actuator Programmable Unitary Controller • Extended Temperature Rated -40° F (-40° C) to 150° F (65.5° C) Programmable Variable Air Volume Controller • Integrated actuator • Integrated on-board pressure sensor Programmable Variable Air Volume Controller • Integrated on-board pressure sensor PU*1012S Inputs • 1 universal input • 0 digital inputs Outputs • 1 analog output • 2 digital outputs PU*4024S Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 4 digital outputs PU*6438S Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs PV*0000AS Inputs • 0 universal inputs • 0 digital inputs Outputs • 0 analog outputs • 0 digital outputs PV*4022AS Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 2 digital outputs PV*6436AS Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 6 digital outputs PV*4024NS Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 4 digital outputs PV*6438NS Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs * = L for Lon, B for BACnet MS/TP
Why Choose the Spyder Platform? • Both Lon and BACnet available • Both protocols available for the same price • Single Tool • Spyder is the only controller that has a common programming interface for Lon and BACnet • Any existing Spyder programs or libraries can be converted to either Lon or BACnet • Programmable • Crate custom applications to meet any need • Multiple I/O and protocol options • Select the controller that meets your needs • Application Library • Easy re-use of applications, standard applications available as a free download on the buildings forum