1 / 22

Autoleak – How to define if when and where to look for leaks

Autoleak – How to define if when and where to look for leaks. Giorgio GALLI SGI Studio Galli Ingegneria SpA Giorgio.galli@sgi-spa.it. Project Information. Cofinaced by EU and Ministry of Environment Duration: 3 years (ended in 2011) Budget: EUR 1.400.000,00

ziazan
Download Presentation

Autoleak – How to define if when and where to look for leaks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Autoleak – How to define if when and where to look for leaks Giorgio GALLI SGI Studio Galli Ingegneria SpA Giorgio.galli@sgi-spa.it

  2. Project Information • Cofinaced by EU and Ministry of Environment • Duration: 3 years (ended in 2011) • Budget: EUR 1.400.000,00 • 2 Pilot sites: Ancona (Italy), Nicosia (Cyprus) • 6 partners (4 engineering consultants + 2 water utilities)

  3. Leakage Control System is Widely Known: so why is leakage so high ? • Lack of priority for leakage • Insufficient Staff • Time consuming analysis • Effort directed to emergencies

  4. Daily Step by Step Leakage Analysis • Extract minimum night flow • Subtract Customer Consumption • Quantify Leakage • Assess if leakage increasing • Decide if worthwhile to locate and repair leaks The Solution isAutomate the process

  5. Autoleak Features Automatically for every DMA AUTOLEAK • Determines current recoverable leakage • Extrapolates rate of rise from historical data • Quantifies value of predicted lost water (Benefit) • Compares with cost of intervention • Decide if worthwhile to intervene

  6. AUTOLEAK – Operative Principle Intervention if V > X

  7. AUTOLEAK Structure AREA DMA Flow - Bulk Flow Meters - Variable time step Pressure - Pressure inlet - Variable time step AMR - Users consumption - Hourly, daily Noise Log - Leak Probability Hystorical Intervention Intervention Cost Historical Consumption Production and retail Cost Import Manager (Imports monitoring data) Geodatabase – GIS Leakage and Intervention Database Quality control of data Leak location module Leak repairs module New Minimum? YES Leakage calculation Estimation of Water Recovered Estimation of Intervention Cost Leakage Detection (Noise Loggers) COST-BENEFIT ANALYSIS Intervention (YES)

  8. Autoleak User Interface

  9. Autoleak DMS – DMA flow, leakage and trend

  10. Calculation of Cost of Intervention • Average Recovered Flow per Leak • Calculation of number of leaks to be repaired • Average Intervention Cost (leakage detection + repair) Historical Intervention NO YES Real Data from DMA Parametric data from similar case studies

  11. Historical Cost of Intervention • Real Data from past interventions • Calculation of Cost and Water Recovery of past leakage intervention • Cost Estimation of future intervention based on the expected water recovery

  12. Assessment of economic convenience • Total value of the recovery (V) • Estimated cost of intervention (X) • if V>X, the intervention will be worthwhile • Priority = (V-X)/km

  13. Leak Repair Report • Leak repair report • Make records of your leak repairs • Provide your staff with site forms to record data • Create statistics of your leak repairs • Create Leakage Maps

  14. Ancona Pilot Area (Multiservizi SpA - Italy) Mean Pressure: 55 m Reservoir Level: 140 m Min. Ground Level: 56,9 m Max. Ground Level: 74 m Water mains length: 1,9 Km Number of consumer meters: 325 Qin

  15. PILOT AREA  3D VIEW PILOT AREA

  16. Ancona Pilot Area AMR – ConnectedDevices Noise Loggers Bulk Meter Collector Users’ Meters

  17. Access Point AUTOLEAK Application - Real Case Example FTP server Internet Connection User Interface Real time leakage calculation Leak Alarm from noise loggers AMR Radio 868MHz

  18. Nicosia Pilot Area (WBN- Cyprus) • Mean Pressure: 17.5 m • Reservoir Level: 349 m • Min. Ground Level: 320 m • Max. Ground Level: 338 m • Water mainslength: 3.5 Km • Mains Material: AC • Numberof consumer meters: 86 • Numberof bulk meters: 4 (2 inlets and 2 outlets)

  19. Description of the system installed-Installation of Concentrator Self Powered Concentrator (Wind & Solar) Concentrator IP 68 BOX Concentrator

  20. Lesson Learned and possible development • AMR Transmission problems in Ancona (then solved) • Initial setup and customization necessary for each pilot application • AMR repeaters mount on light pole, authorization needed • Technology Improvement • Next development in data transmission (electricity, ADSL, cable? ….) • Full Automatic Correlation

  21. Conclusions - Advantages of Autoleak • Interfaces with all currently available technology including AMR • Data Integration • Makes managing leakage almost fully automatic • Allows to save investment focusing on interventions where the expected benefit is greater www.autoleak.eu

  22. THANK YOU!

More Related