RadMon positions near end of TI 8. Comparison between BCT readings and hadron fluences ; dose calculations. Full SPS batch on TED seems likely to cause some hiccups on electronics in UA87. Interested to see higher intensities soon,

zoltan
Download Presentation

RMon 8

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RadMon positions near end of TI 8 Comparison between BCT readings and hadronfluences; dose calculations. Full SPS batch on TED seems likely to cause some hiccups on electronics in UA87. Interested to see higher intensities soon, to evaluate need for counter-measures (additional shielding ?). RMon 5 RMon 6 RMon 8 RMon 7 Courtesy: D.Kramer, (EN-STI) V.Mertens / IEFC - 11.6.2009 / TI 8 beam test 6/7 June

  2. Shielding wall UJ88-UA87 • Shielding Wall : • Ad hoc design • Not based on MC simulations • Several holes in the wall • Radiation from TED propagates into UJ87/UA87 • PCs for warm magnets at < 1 m distance from the shielding wall • No electronics in UA87 has been designed with radiation as a constraint • Blocking of holes was discussed in R2E • Committee in January 2008, see : • http://r2e.web.cern.ch/R2E/FollowUp/LHCducts_roesler.pdf

More Related