Objectives. Explain the principle and performance of electrophoresis as it applies to nucleic acids.Compare and contrast agarose and polyacrylamide gel polymers. Explain the principle and performance of capillary electrophoresis as it is applies to nucleic acid separation.Describe the general types of equipment used for electrophoresis.Discuss methods and applications of pulsed field gel electrophoresis.Compare and contrast detection systems used in nucleic acid applications..
E N D
1. Chapter 5: Resolution and Detection of Nucleic Acids Donna C. Sullivan, PhD
Division of Infectious Diseases
University of Mississippi Medical Center
2. Objectives Explain the principle and performance of electrophoresis as it applies to nucleic acids.
Compare and contrast agarose and polyacrylamide gel polymers.
Explain the principle and performance of capillary electrophoresis as it is applies to nucleic acid separation.
Describe the general types of equipment used for electrophoresis.
Discuss methods and applications of pulsed field gel electrophoresis.
Compare and contrast detection systems used in nucleic acid applications.
3. Gel Electrophoresis Electrophoresis is the movement of molecules by an electric current.
Nucleic acid moves from a negative to a positive pole.
Nucleic acid has a net negative charge, they RUN TO RED
4. Electrophoresis of Nucleic Acids Nucleic acids are separated based on size and charge.
DNA molecules migrate in an electrical field at a rate that is inversely proportional to the log10 of molecular size (number of base pairs).
Employs a sieve-like matrix (agarose or polyacrylamide) and an electrical field.
DNA possesses a net negative charge and migrates towards the positively charged anode.
5. Applications of Electrophoretic Techniques in the Molecular Diagnostics Laboratory Sizing of Nucleic Acid Molecules
DNA fragments for Southern transfer analysis
RNA molecules for Northern transfer analysis
Analytical separation of PCR products
Detection of Mutations or Sequence Variations
6. Principles of Gel Electrophoresis Electrophoresis is a technique used to separate and sometimes purify macromolecules
Proteins and nucleic acids that differ in size, charge or conformation
Charged molecules placed in an electric field migrate toward either the positive (anode) or negative (cathode) pole according to their charge
Proteins and nucleic acids are electrophoresed within a matrix or "gel"
7. ELECTROPHORESIS
8. Principles of Gel Electrophoresis The gel itself is composed of either agarose or polyacrylamide.
Agarose is a polysaccharide extracted from seaweed.
Polyacrylamide is a cross-linked polymer of acrylamide.
Acrylamide is a potent neurotoxin and should be handled with care!
9. Gel Electrophoresis Matrices
10. Types Of Nucleic Acid Electrophoresis Agarose gel electrophoresis
DNA or RNA separation
TAE or TBE buffers for DNA, MOPS with formaldehyde for RNA
Polyacrylamide gel electrophoresis (PAGE)
Non-denaturing (Special applications in research)
Denaturing contain 6-7 M Urea (Most common)
11. Agarose Gel Electrophoresis Separates fragments based on mass, charge
Agarose acts as a sieve
Typically resolve 200 bp-20 kbp
fragments <200 bp, polyacrylamide gels
fragments> 20 kbp, pulse field gels
Include DNA size standards
12. Factors That Effect Mobility Of DNA Fragments In Agarose Gels Agarose Concentration
Higher concentrations of agarose facilitate separation of small DNAs, while low agarose concentrations allow resolution of larger DNAs (Remember-inversely proportional!)
Voltage
As the voltage applied to a gel is increased, larger fragments migrate proportionally faster that small fragments
Charge is evenly spread (uniform) so the larger fragments will have more charged groups
13. Factors That Effect Mobility Of DNA Fragments In Agarose Gels Electrophoresis Buffer
The most commonly used for double stranded (duplex) DNA are TAE (Tris-acetate-EDTA) and TBE (Tris-borate-EDTA).
Effects of Ethidium Bromide
Staining dye that inserts (intercalates) into the DNA between the nitrogenous bases (“rungs of the ladder”) and glows when exposed to UV light
Binding of ethidium bromide to DNA alters its mass and rigidity, and therefore its mobility
14. Comparison of Agarose Concentrations
15. Fragment Resolution: Agarose Gel Electrophoresis
16. Gel Electrophoresis: The Basics The movement of molecules is impeded in the gel so that molecules will collect or form a band according to their speed of migration.
The concentration of gel/buffer will affect the resolution of fragments of different size ranges.
Genomic DNAs usually run as a “smear” due to the large number of fragments with only small differences in mass
17. Agarose Electrophoresis of Restriction Enzyme Digested Genomic DNA
18. Gel Electrophoresis: Apparatus and Types of Gels Horizontal Gel Units (“Submarine Gels”)
Most DNA and RNA gels
Agarose
Vertical Gel Units
Polyacrylamide gels
Typically sequencing gels
Pulse Field Gel Units
Any electrophoresis process that uses more than one alternating electric field
Agarose
Large genomic DNA (Chromosomal)
19. Electrophoresis Equipment: Horizontal or Submarine Gel
20. Agarose Gel Electrophoresis
21. Agarose Gel ElectrophoresisHorizontal Gel Format
22. Agarose Gel Apparatus
23. Electrophoresis Equipment: Vertical Gel
24. Vertical Gel Format: Polyacrylamide Gel Electrophoresis
25. Polyacrylamide Gel Electrophoresis (PAGE)
26. Electrophoresis Equipment Combs are used to put wells in the cast gel for sample loading.
Regular comb: wells separated by an “ear” of gel
Houndstooth comb: wells immediately adjacent
27. PULSE FIELD GEL ELECTROPHORESIS APPARATUS
28. Types Of Pulse Field Gel Electrophoresis
29. Pulse Field Gel Electrophoresis Used to resolve DNA molecules larger than 25 kbp
Periodically change the direction of the electric field
Several types of pulsed field gel protocols
FIGE: Field inversion gel electrophoresis
TAFE: Transverse alternating field electrophoresis
RGE: Crossed field electrophoresis
CHEF: Contour-clamped homogeneous electric field
30. Critical Parameters: Pulse Field Gel Electrophoresis Depend on time it takes molecules of various sizes to change directions in a gel
Small DNA molecules are sieved (pass through the pores in the agarose gel)
Large DNA molecules are not “sieved” but “squeezed” through the gel at about the same rate, called the limiting mobility
31. Size of Fragments and Distance Traveled Not Linear When Large Fragments Are Analyzed
32. Movement Of DNA In Gels
33. Pulse Field Gel Electrophoresis PFGE works by periodically altering the electric field orientation
The large extended coil DNA fragments are forced to change orientation
Size dependent separation is re-established because the time taken for the DNA to reorient is size dependent
34. Comparison of Migration: Horizontal vs. CHEF
35. Preparation Of Intact DNA For PFGE Conventional techniques for DNA purification (organic extraction, ethanol precipitation) produce shear forces
DNA purified is rarely greater than a few hundred kb in size
This is clearly unsuitable for PFGE which can resolve mb DNA
The problem of shear forces was solved by performing DNA purification from whole cells entirely within a low melting temperature (LMT) agarose matrix
36. Preparation Of Intact DNA For PFGE Intact cells are mixed with molten low melting point (LMT) agarose and set in a mold forming agarose ‘plugs’
Enzymes and detergents diffuse into the plugs and lyse cells
Proteinase K diffuses into plugs and digests proteins
If necessary restriction digests are performed in plugs (extensive washing or PMSF treatment is required to remove proteinase K activity)
Plugs are loaded directly onto PFGE and run
37. FIGE GEL
38. CHEF: Contour-Clamped Homogenous Gel Electrophoresis Based on hexagonal array of alternate electric fields at 120 degree angle
Generates a more uniform electric field when compared to other PFGE systems
Programmable, autonomously controlled electrodes
Extremely versatile system based on CHEF hexagonal array
All electrophoretic parameters can be controlled at each electrode
Can generate electric field and switching characteristics of any PFGE system
39. PFGE of Bacterial DNA
40. Using PFGE In The Molecular Investigation Of An Outbreak Of S. marcescens Infection In An ICU An outbreak due to S. marcescens infection was detected in the ICU
A total of 25 isolates were included in this study:
12 isolates from infected patients
nine isolates from insulin solution
one isolate from sedative solution
one isolate from frusemide solution
two isolates from other wards which were epidemiologically-unrelated
41. Using PFGE in the Molecular Investigation Of An Outbreak of S. marcescens Infection in an ICU
42. Using PFGE in the molecular investigation of an outbreak of S. marcescens infection in an ICU The S. marcescens from patients, insulin solution and sedative solution showed an identical PFGE fingerprint pattern.
The isolate from the frusemide solution had a closely-related PFGE pattern to the outbreak strain with one band difference.
Found that the insulin and sedative solutions used by the patients were contaminated with S. marcescens and the source of the outbreak.
43. Comparison Of Agarose Gel And PFGE
44. Polyacrylamide Gel Electrophoresis (PAGE) PAGE is the preferred method for PROTEINS but can be used for DNA/RNA
Gel prepared immediately before use by copolymerization of acrylamide and N,N'-methylene bis acrylamide under UV light.
Porosity controlled by proportions of the two components.
Larger pore size for larger proteins.
Gradient gels also possible.
45. Electrophoresis of Nucleic Acids Polyacrylamide Gel Electrophoresis (PAGE) Advantages
High degree of resolving power.
Can effectively and reproducibly separate molecules displaying 1 bp differences in molecular size.
Optimal separation is achieved with nucleic acids that are 5–500 bp in size.
46. Electrophoresis of Nucleic Acids Polyacrylamide Gel Electrophoresis (PAGE) Typical Conditions
Vertical gel setup, TBE buffer (Tris-borate/EDTA) and constant power.
Disadvantages
Acrylamide monomer is a neurotoxin.
Polyacrylamide gels can be difficult to handle.
47. Electrophoresis of Nucleic AcidsAgarose Gel Electrophoresis Advantages
Greater range of separation of nucleic acid molecules.
Optimal separation is achieved with nucleic acids that are 200 bp to 30 kb in size.
Ease of preparation and handling.
48. PAGE: Critical Parameters Polymerization reaction critical
High grade acrylamide, bis-acrylamide
Break down into acrylic acid (long shelf life solutions incorporate inhibitors of polymerization)
Must have even heat distribution to prevent “smiling”
49. Polymerization Of Polyacrylamide
50. PAGE: DNA High resolution of low molecular weight nucleic acids (500bp)
Polymerization of acrylamide monomers into long chains
Cross link chains with bis-acrylamide
Initiated by free radicals in ammonium persulfate, stabilized by TEMED
Pore size determined by % acrylamide
51. Electrophoresis of Nucleic Acids: Polyacrylamide Gel Electrophoresis (PAGE) Typical Conditions
Vertical gel setup, TBE buffer
(Tris-borate/EDTA) and constant power.
Disadvantages
Acrylamide monomer is a neurotoxin.
Polyacrylamide gels can be difficult to handle.
52. PAGE Fragment Resolution: Denaturing Conditions (6M Urea)
53. PAGE Fragment Resolution: Non Denaturing PAGE
54. Polyacrylamide Gel Electrophoresis of Restriction Digested PCR Products
55. Denaturation of DNA: Urea and Formamide Both formamide and urea effectively lower the melting point of the DNA molecules, allowing the structures to fall apart at lower temperatures. Generally, concentrations of urea or formamide are chosen to give melting temperatures around 50° C, and gels are run at that temperature. RNA is often denatured with harsher agents, because RNA tends to form stronger structures. Both formamide and urea effectively lower the melting point of the DNA molecules, allowing the structures to fall apart at lower temperatures. Generally, concentrations of urea or formamide are chosen to give melting temperatures around 50° C, and gels are run at that temperature. RNA is often denatured with harsher agents, because RNA tends to form stronger structures.
56. Preparation of Polyacrylamide Gel Pour into glass plate gel sandwich and polymerize.
Prepare DNA samples by adding loading buffer.
Document and verify loading order of samples and electrophoretic conditions (voltage).
Stain gel, visualize DNA, photograph/ document and dispose of gel properly.
57. PAGE of Restriction Digested PCR Products