0 likes | 7 Views
<br>Atomic Absorption Spectrophotometer is a fast and accurate microprocessor controlled analyzer with built-in computer data processing and LCD display. Analysis of metal ions <br>by air-acetylene flame and graphite furnace atomizer with absorption at 190 to 900 nm wavelength. Features Czerny-Turner monochromator 1200 line/mm grating optics, paired <br>with D2 background correction avails greater performance. Multiple atomizer configurations allow high-intensity analysis and ultimate ease of use within multiple <br>applications settings such as environmental, agricultural and clinical, as well as high th
E N D
Atomic Absorption Spectrophotometer FM-AAS-A100 https://www.fison.com/|info@fison.com
Description : Atomic Absorption Spectrophotometer is a fast and accurate microprocessor controlled analyzer with built-in computer data processing and LCD display. Analysis of metal ions by air-acetylene flame and graphite furnace atomizer with absorption at 190 to 900 nm wavelength. Features Czerny-Turner monochromatic 1200 line/mm grating optics, paired with D2 background correction avails greater performance. Multiple atomizer configurations allow high- intensity analysis and ultimate ease of use within multiple applications settings such as environmental, agricultural and clinical, as well as high throughput labs. Features: Integrated flame/graphite furnace atomization system, changeable with flame emission burner Turret for 6 pre-aligned hollow cathode lamps fitted with pre-heating, and individual pre-centered lamps Spectral bandwidth of 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm Characteristic concentration of copper: ≤0.04 mg/ml/1% Detection limit of copper: ≤0.008 mg/ml Built-in computer data processing system and LCD display Double-beam system compensates light source and wavelength drift caused by temperature variation Gas path system equipped with precision pressure stabilizing and current stabilizing devices Multi-functional analysis mode: flame absorption, flame emission, graphite furnace atomic absorption and hydride generation Integrated functions: integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting Various parameters and working curves displayed in screen and report printing
It is equipped with autosampler and RS232 interface for externally linking PC Specifications: Wavelength range 190 to 900 nm Wavelength accuracy ≤ ±0.5 nm Wavelength repeatability ≤0.3 nm (single direction) 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm Spectrum bandwidth Resolution < 40% Base line stability ±0.004 Abs/30 min Grating 1200 lines / mm Inflamer All-metal titanium burner with 10 cm slit Atomizer Efficient glass atomizer Lamp Hollow cathode lamp 6 lamps automatic turret, automatic alignment Lamp stand
Characteristic concentration of copper ≤0.04 mg/ml/1% Detection limit of copper ≤0.008 mg/ml D2 Background calibration ability Greater than 30 times Flame system Air-acetylene flame system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner Protection system Standard interface RS232 Power supply 220 V/ 50 Hz, 3 A Gross weight 160 kg Applications: Used in different areas of chemistry such as clinical analysis of metals in biological fluids and tissues such as whole blood, plasma, urine, saliva, brain tissue, liver, hair, muscle tissue, semen, in some pharmaceutical manufacturing processes, minute quantities of a catalyst that remain in the final drug product, and analyzing water for its metal content.
Accessories: Accessories no Accessories name 1. Oil-free air compressor 2. Glass Atomizer 3. Cu Hollow cathode lamp 4. Atomizer unit 5. Burner unit 6. Dust cover 7. Water-separating gas filter 8. Titanium burner: slit 10 cm
Accessories Optional: Accessories no Accessories name 1 GRAPHITE FURNACE SYSTEM: Heating steps- 9 steps Temperature range: 20°C to 3000°C Slope heating time: 0 to 999 s Heating holding time: 0 to 999 s Inert gas: argon Inert gas pressure: 0.3 MPa Cooling water flow rate: 2 L/min Characteristic quantity: (Cd) ≤ 1 × 10 -12 g, (Cu) ≤ 1 × 10 -10 g Power supply: 220 V/50 Hz 3A Ambient temperature: 10 to 30 °C Relative humidity: less than 85% 2 Hydride generator 3 Graphite tubes 4 Acetylene Regulator 5 Printer 6 Software Fison Instruments Ltd 272 Bath Street Glasgow G2 4JR UK Email: info@fison.com | Website: www.fison.com