An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Detector systems to find HFS of 209Bi80+ @ ESR • Emission characteristics • Counting rates at existing mirror section • Straight on detector option • Parabolic mirror system • Outlook Denis Anielski, Volker Hannen, Raphael Jöhren, Christian Weinheimer Westfälische Wilhelms-Universität Münster 02.04.2009

  2. Relativistic Doppler Effect and Boost (β = 0.71) • Relativistic Doppler Effect λ = λ´γ(1- βcos(θ)) θ= 0° → 640nm λ´ = 1555nm θ= 40° → 1000nm • Observed angle • Boost

  3. Simulation of Boost Polar angles in the comoving system Polar angles in the lab system (Isotropic light source) A(0°,10°) = 4% A(10°;30°) = 25% A(10°;50°) = 52% → Most photons not in straight forward direction, because of sin(θ) in solid angle!

  4. Ideas For Detector Systems

  5. General Assumptions • Number of excited ions: 2 e5 • Lifetime in lab system: 82 ms [1] • Lifetime in comoving system: 116 ms • QE = 10% • Circumference of ESR: 108 m • β = 0.71 [1] V. M. Shabaev, PHYSICAL REVIEW A, JAN 1998

  6. Mirror System • 10 elliptical mirrors on a 65cm section • Original simulation software not available • First order estimate: geometric count rate estimate • Realistic simulations using GEANT4 under progress

  7. Estimated counting rate Counting rate is proportional to • Emitted photons per second NPh = N/tau = 1,72 e6 • Ratio of totally emitted photons A = 0.38 (646 nm – 950 nm; 5°-37° ) • Loss by reflexion and transmission R*T = 1/3 (R=0.35!!!) • Quantum efficency QE = 0,1 • Relevant beam section b = 0.065m/ 108m • Geometry of mirror system g = 2/3 • Number of windows (dia: 7cm) # = 3 → f = NPh · A · g · RT · QE · b · # = 26 Hz

  8. Straight on option • Diameter of window: 60mm • Straight beam section: 17 m • Distance – beam – detector: 3,5 m • All Photons are focused on detector by a lense • Transmission of lense: 0.9 → 0,36 Hz (simulation c++)

  9. Parabolic mirror Detects forward emission → short wavelengths

  10. Parabolic mirror Assumptions • Reflectivity coefficient: 0.8 • Hole in mirror with diameter of 2cm for the beam GEANT4 model www.edmundoptics.com

  11. 2-flange option • Diameter of flange for mirror: 10 cm • Diameter of flange for detector: 3.8 cm • Distance: Beam - Detektor: 30 cm • Straight section before mirror: 5 m • Radius of mirror: 5 cm • Lightguide as interface from window to detector • GEANT4 simulation (Volker Hannen) → 15 Hz

  12. 2-flange option

  13. 1-flange option – C++ Simulation • Diameter of flange: 20 cm • Distance: Beam - Detektor: 25 cm • Straight section before mirror: 5 m / 10 m • Radius of mirror: 7.5 cm • Radius of detector/ focussing system: 3 cm • Counting rate is multiplied by 0.9 because of slit → 45Hz / 60 Hz (Flange is just in front of mirror system!) Possible improvement with recessed exit window (distance beam – exit window = 15cm): 154 Hz

  14. CPM beam tests • Two setups have been installed at ESR yesterday • Investigations of background photons and behaviour of CPM next to dipole magnet • Positions: • 2-flange option • Straight on option • Detectors: Channel-Photomultiplier • Easy to handle • Low dark count rate • Only 2% QE around 650nm • Suitable for 244nm transition at SPECTRAP (QE= 18%)

  15. Conclusions • Mirror system: • 26 Hz, but dark counts of three detectors, broad wavelength range • Reflexion of mirror? • Not all three windows present • ??? • Straight on • very low rate ( < 1Hz) • ??? • Parabolic mirror • System with highest counting rate on a SINGLE detector • Small wavelengths (640 – 680nm) • !!!

  16. Outlook • Detailed GEANT4 simulation of existing mirror system and search for best parameters of parabolic mirror system • Test of Hamamatsu R943-02 PMT (suitable detector for parabolic mirror system)