An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CUE Well Reliability COIN Meeting Jan 26th, 2011 Robert Steneker

  2. CUE (UK Assets) – Management of Well Reliability Topics to be covered: • Well Operations Policy • Well Integrity Dashboard • Well Integrity Panel Key Point: The Asset owns Well Integrity

  3. CUE – Well Ops Policy • The purpose of the CUE Well Ops Policy is to: • Define what is a well Anomaly • Define interfaces/roles and responsibilities of those involved with the Management of wells • Specify the monitoring, maintenance, testing and reporting requirements required for these wells. • Explain the concept of a “Well Integrity Panel” and detail its role and responsibilities.

  4. CUE – What Constitutes an Anomaly • Change in annulus pressure regime. • Failed test of any surface or Down hole valves • Change in the nature of produced fluids (H2S, CO2, sand, etc). • Deferment of a planned well maintenance activity/test. • Conductor centraliser movement as noted during topsides structural inspections or Subsea DSV inspections • Any other failure of the Well Performance Standard

  5. CUE – Well Anomaly Process Well Anomaly ID’ed by asset Safe to Continue? N WAR Generated Shut in Well Y RA required? Y N Make changes defined by WAR Conduct RA, approved by WTA/WE Follow RA Recommendations WAR – Well Anomaly Report RA – Risk Assessment WTA – Well technical Authority WE - Well Examiner

  6. CUE – Well Integrity Dash Board

  7. CUE – Well Integrity Dash Board Downhole Equipment

  8. CUE – Well Integrity Panel • The standing members of the WIP shall be represented by the following job functions as a minimum: • Senior Completions Engineer (Chair); • Drilling and Completions Co-ordinator; • Well Services Co-ordinator; • Xmas Tree and Wellheads Specialist; • Production Engineers • Maintenance, Reliability & Integrity Engineer; • Well Examiner • Audit Function of the Assets (asset presents current condition to WIP) • Supplies Technical support as required to the Asset • Facilitates best practise sharing across the assets • Reports to Sr. Management on a Monthly Basis with Trends and issues