1.1 Customer Concept. sampling frequency : 138.24MHz / Interpolation : 4x Enable Digital Mixer fs /2 Disable NCO. FPGA 138.24MSPS DATA. ADC. DAC3484. 241.92MHz. 241.92MHz. Testing for TSW1400 + DAC3484 EVM. 1. Test Configuration. Signal Generator. Spectrum. TSW1400. DAC34H84EVM.

Download Presentation

FPGA 138.24MSPS DATA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1.1 Customer Concept • sampling frequency : 138.24MHz / Interpolation : 4x • EnableDigital Mixer fs/2 • Disable NCO FPGA 138.24MSPS DATA ADC DAC3484 241.92MHz 241.92MHz

  2. Testing for TSW1400 + DAC3484 EVM

  3. 1. Test Configuration Signal Generator Spectrum TSW1400 DAC34H84EVM PC

  4. 3. Test Result - Signal source file: single tone - F sampling frequency : 307.2MHz / Interpolation : 4x [TSW1400] [DAC3484] [DAC34H84 Register] [Spectrum] Test Result : Normal

  5. 3. Test Result - Signal source file: WCDMA_TM1_complexIF30MHz_Fdata307.2MHz_1000 - F sampling frequency : 307.2MHz / Interpolation : 4x If see below spectrum capture, Sidelobe graph don’t clean. This condition is a problem in system properties. Please check register setting [TSW1400] [DAC3484] [DAC34H84 Register] [Spectrum] Test Result : PLL LOCK Normal

  6. 3. Test Result - Signal source file: WCDMA_TM1_complexIF30MHz_Fdata307.2MHz_1000 - F sampling frequency : 307.2MHz / Interpolation : 2x [TSW1400] [DAC3484] [DAC34H84 Register] [Spectrum] Test Result : Normal

  7. 3. Test Result - Signal source file: single tone - F sampling frequency : 138.24MHz / Interpolation : 2x PLL lock does not. Please check register setting. [TSW1400] [DAC3484] PLL unlock [DAC34H84 Register] [Spectrum] Test Result : Abnormal Signal unstable Center Freq mismatch