Improvements of the A2 beamline for the linear polarised beam

Improvements of the A2 beamline for the linear polarised beam. Patrik Ott Institut für Kernphysik Johannes-Gutenberg Universität Mainz 28.02.2011. Content. Motivation Characteristics of linear polarised photon beam Why do we need these two devices Beam Stabilisation Recent Status

Download Presentation

Improvements of the A2 beamline for the linear polarised beam

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Improvements of the A2 beamline for the linear polarised beam Patrik Ott Institut für Kernphysik Johannes-Gutenberg Universität Mainz 28.02.2011

  2. Content • Motivation • Characteristics of linear polarised photon beam • Why do we need these two devices • Beam Stabilisation • Recent Status • Possible automation? • Pair-Spectrometer

  3. Colli at 7.5 m pol. 70% Colli at 5.0 m pol. 58% Colli at 2.5 m pol. 44% Ken Livingsten Characteristics of linear polarised photon beam • Large incoherent background • Coherent part is strongly collimated Therefore collimation is a simple way to increase the relative amount of coherent linear polarised photons in the beam Coherent peak Roman Leukel, Diss. 2001

  4. Problems of the collimation So far we have no possibility to measure the coherent peak without analysing the data Cause of the small emission angle, a small deviation of the electron beam can cause the complete loss of the linear polarised photons

  5. Position control

  6. A2-Beamline • TM110 Scanners • The stabilisation converges best with the correction magnets SFA2WEDL06 and SFA2WEDL08.

  7. Measuring the position in both cavities as a function of the current in both correction magnets With these gradients one can calculate the necessary change of current. The Hysteresis of the correction magnets cause an unpredictable error. Due to this only 90% of the aberration is compensated. After a few iterations the nominal position is reached without oscillation.

  8. Magnet 1 Magnet 2 Measuring the position in both cavities as a function of the current in both correction magnets Cavity1 Necessity for convergence: Different slopes for both magnets in at least one cavity Cavity2

  9. Lock-in amplifier Cavity output • Add a reference Signal of 2.45 GHz – 100 kHz to reduce the frequency • Measure the output signal at a time defined by the MAMI main oscillator • To adjust the phase ∆φ one needs to steer the beam highly. This produces a large output signal so that the Lock-in amplifier can find a reproducible reference phase. 2.45 GHz 100 kHz 2.45 GHz – 100 kHz MAMI main oscillator ∆φ 2.45 GHz Wavelength : 12.2 cm A difference of the electron path through MAMI of 2 cm reduces the signal output to one half.

  10. Measured horizontal beam position Position is measured 25 times before switching to the other orientation. This is done to conserve the HF-Relay.

  11. Measured vertical beam position Position is measured 25 times before switching to the other orientation. This is done to conserve the HF-Relay.

  12. MAMI-Optimisation After a MAMI-optimisation the beam position often has a large offset, but the operator can bring back the beam with one button.

  13. Position Control • After the first 2 days of beam time, the accelerator is in thermal equilibrium and the position is quite stable. • If an aberration is detected, it is not clear if the reference phase or the beam position is not right. • Due to this, there is no automation so far. The operator gets an acoustic signal and adjusts the phase again. If an aberration is still detected he can correct the beam. • During the phase adjustment we need the blank radiator. • After a MAMI-optimisation the operator can bring back the beam with one button.

  14. Pair-Spectrometer

  15. Experimental setup Measure the tagger channels in coincident with the Pair-Spectrometer to get the coherent Peak.

  16. Hamamatsu APD • No need of HV • Is not disturbed by magnetic fields • easy connection with scintillator Dark current Signal

  17. First tests • Does the setup work with the APD? • Measure the influence of the current and thefoil-thickness • Can we find the coincident of both scintillators? • Find the timing between Pair-Spectrometer and Tagger (Moeller-FPGA)

  18. Pair-Spectrometer To do list: • Provide an excellent grounding of the electronic to suppress noise. • Find the correct timing in the FPGA • Open the beam line to build in longer scintillators.