An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 47_84 48_84 49_84 52_84 51_84 50_84 New 90% Furnaces Features • Reduced cabinet height from 40” to 34.5” • Reduced width • 80,000 BTU’s in 17.5” wide cabinet • 100,000 BTU’s in 21” wide cabinet • All families 3 position installation • up/horz left-right • down/horz left-right • Top line efficiency 97% AFUE

  2. Daikin New 90% Furnace Families

  3. Daikin New 90% Furnace Families

  4. New 90% Furnace Heat Exchanger • Firing rate of 20,000 BTU per burner • Heat Exchanger improvements • Rear Header from Aluminized Steel to Stainless Steel • 1 piece tubular heat exchanger with optimized combustion air velocity • No joining of duel diameter tubes • Secondary heat exchanger from 1/2 “ to 3/8” diameter tubes • 2 years of field trials on production tooled heat exchangers Rear Header

  5. VOC Driven Features • Internal trap plumbed for upflow • Thumb screws for easy door access • Improved door fit • Single screw size for simplified service • Vertical gas valve for easy field connections • Door sight glass aligns with control board LED • Capacitor mounted on front face of control board • Additional inlet air options, top plus both sides • Improved access to flame sensor & igniter • Downflow vent motor standardized with upflow

  6. Quality Improvements • Silicon Nitride igniter on all models • Improved reliability over silicon carbide • “D” shaped blower hub • Guarantees blower set screw aligns with the flat on motor shaft • Pan head screws on wrapper sides • Smooth sides minimize scratching door frames • Embossed single piece wrapper • Added cabinet strength and reduced air leakage • Reduced sharp edges & corners on sheet metal • Raised wire penetration area • Prevents condensate from running down wires to controls • Improved burner bracket design • Burner alignment critical to combustion • Eliminated blower insulation notches • Improved cabinet insulation

  7. Daikin 90 % Furnace Nomenclature

  8. New 90% Daikin Furnace Models 20K BTU firing rate Consistent Nomenclature 13 additional models for a total of 50 per Brand

  9. A Winning Combination • Reduce cabinet height & width • Top of line efficiency increase • Additional models • Horizontal and downflow applications • Improved airflow sizing, 60k BTU 2 tons, 80k BTU in 3, 4 & 5 tons • 30k BTU model • Enhanced dealer feature • Pre-installed trap • Gas valve location • Heat exchanger reliability improvements