110 likes | 309 Views
Applications of the NWS FLDWAV Model. Teton Dam Failure on Snake River. Teton Dam Failure Specifications. Dam Height: 300 ft Crest Length: 3,000 ft Storage behind dam: 250,000 acre-ft Dam crest width: 35 ft Slope of upstream dam face: 1:2 Slope of downstream dam face: 1:2.5.
E N D
Teton Dam FailureSpecifications Dam Height: 300 ft Crest Length: 3,000 ft Storage behind dam: 250,000 acre-ft Dam crest width: 35 ft Slope of upstream dam face: 1:2 Slope of downstream dam face: 1:2.5 Failure occurred June 6, 1976 11 people killed 25,000 people homeless $400M damage Peak Outflow: 1.6 – 2.8 million cfs (2.3M best estimate) Breach shape – trapezoid. Max width 500 ft; side slope 1 : 0.5 Reservoir depleted in 5 hrs
RED RIVER LDG (MI 302.4) MORGANZA DIVERSION BATON ROUGE DONALDSONVILLE RESERVE BONNET CARRE DIVERSION MISSISSIPPI NEW ORLEANS CHALMETTE GAGING STATION AND COMPUTATIONAL NODE PT A LA HACHE COMPUTATIONAL NODE LATERAL INFLOW OR OUTFLOW VENICE (MI 10.7) Lower Mississippi River