250 likes | 357 Views
Are the relativistic Fe lines really relativistic?. Traineeship 2009 :. A systematic analysis of the Fe K line from inner region of accretion disk of Neutron star LMXB with XMM-Newton. Supervisors : Maria Diaz- Trigo Marion Cadolle Simone Migliari. Cherry Ng September 24 th 2009.
E N D
Are the relativistic Fe lines really relativistic? Traineeship 2009 : A systematic analysis of the Fe K line from inner region of accretion disk of Neutron star LMXB with XMM-Newton • Supervisors: • Maria Diaz-Trigo • Marion Cadolle • Simone Migliari Cherry Ng September 24th 2009
Outline Fe K emission line Inner region of the accretion disk Objectives Data analysis Results Conclusion Importance of pile-up treatment Relativistic Fe K line ? Outline
Neutron Star Low-mass X-ray binaries (NS LMXB) Low-mass star Roche-lobe overflow Accretion disk Weakly magnetized NS • Fe K emission line • Typical energy : ~ 6.5keV Objectives
Neutron Star Low-mass X-ray binaries (NS LMXB) Cackett et al (2008) ApJ 674:415-420 Low-mass star Roche-lobe overflow Accretion disk Weakly magnetized NS • Fe K emission line • Typical energy : ~ 6.5keV Objectives
Neutron Star Low-mass X-ray binaries (NS LMXB) • Systematic analysis • All publicly available bright Neutron Star LMXB • XMM-Newton • 26 observations • 17 sources Objectives
Treatment of Pile-up Single & Double-px event pattern plot of Ser X1 No. of counts normalized to 1 • Common problem of bright sources • 2 photons of lower energy read as 1 photon of higher energy • Distortion of spectra Data analysis
Treatment of Pile-up Single & Double-px event pattern plot of Ser X1 No. of counts normalized to 1 Single-px event Double-px event • Common problem of bright sources • 2 photons of lower energy read as 1 photon of higher energy • Distortion of spectra Data analysis
Treatment of Pile-up Single & Double-px event pattern plot of Ser X1 Comparison of Ser X1 spectra before and after pile-up removal No. of counts normalized to 1 Single-px event Double-px event • Common problem of bright sources • 2 photons of lower energy read as 1 photon of higher energy • Distortion of spectra Data analysis
Treatment of Pile-up Single & Double-px event pattern plot of Ser X1 Comparison of Ser X1 spectra before and after pile-up removal No. of counts normalized to 1 Single-px event Excessemission Double-px event Before pile-up removal After pile-up removal • Common problem of bright sources • 2 photons of lower energy read as 1 photon of higher energy • Distortion of spectra Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian diskbbody+bbodyrad Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs abs gaussian diskbbody+bbodyrad diskbbody+bbodyrad Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian diskbbody+bbodyrad Fe K line gaussian+gaussian gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian gaussian diskbbody+bbodyrad Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian gaussian diskbbody+bbodyrad Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian diskbbody+bbodyrad Fe K line Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian diskbbody+bbodyrad Fe K line Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs gaussian diskbbody+bbodyrad Fe K line gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Evolution of spectrum fit ( + + ) + abs abs gaussian gaussian diskbbody+bbodyrad diskbbody+bbodyrad Fe K line Fe K line gaussian+gaussian gaussian+gaussian calib 1.84keV calib 2.28keV Emission 1keV Data analysis
Gaussian & Laor comparison on 4U 1543-62 Gaussian Laor Data analysis
Gaussian & Laor comparison on 4U 1543-62 Gaussian Laor Data analysis
Gaussian & Laor comparison on 4U 1543-62 Gaussian Laor Data analysis
Gaussian & Laor comparison on 4U 1543-62 Gaussian Laor • Narrow line width • Small inner radius • Similar X² • Insignificant evidence of asymmetric profile Data analysis
Statistics on equivalent width Results
Conclusion • Relativistic origin for the broadening of Fe cannot be claimed • Further higher resolution spectroscopic data needed --> to place better constraints on possible contribution to the line emission from various parts of disk Thankyou ! Conclusion