1 / 28

LH PAX p. 2-15

BCD p. 16-28. KEEL. AFT. LH PAX p. 2-15. LH PAX (VIEW LOOKING INWARD). KEEL. AFT. 1794. 1744. P1. 2. Step 1 : Use GREEN Setup (5/16” CFRP/Ti w/CSK) Drill Qty 4 Locations (ID 1) Drill Qty 6 Locations (ID 2) Drill Qty 4 Locations (ID 3) Drill Qty 2 Locations (ID 4)

alexis
Download Presentation

LH PAX p. 2-15

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BCD • p. 16-28 KEEL AFT LH PAX p. 2-15

  2. LH PAX (VIEW LOOKING INWARD) KEEL AFT 1794 1744

  3. P1 2 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 4 Locations (ID 1) • Drill Qty 6 Locations (ID 2) • Drill Qty 4 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 5) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 2 Locations (ID 6) • Step 3: Use WHITE Setup (3/8” CFRP/Ti w/CSK ) • Drill Qty 2 Locations (ID 7) • Drill Qty 4 Locations (ID 8) • Drill Qty 3 Locations (ID 9) • Drill Qty 3 Locations (ID 10) • Drill Qty 2 Locations (ID 11) • Drill Qty 1 Location (ID 12) • Step 4: Use PINK Setup (3/8” CFRP/Ti Drill Only) • Drill Qty 3 Locations (ID 13) • Step 5: Use BLACK Setup (1/4” CFRP/Ti w/CSK) • Drill Qty 2 Locations (ID 14) 3 LH PAX 1 2 5 6 1 2 2 3 1744 1794 3 4 4 6 8 7 KEEL 9 8 10 13 AFT 11 13 12 13 11 10 10 9 9 8 8 7 2 3 2 1 5 1 14 14

  4. P2 10 17 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 3 Locations (ID 1) • Drill Qty 4 Locations (ID 2) • Drill Qty 2 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 1 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 10) • Step 2: Use WHITE Setup (3/8” CFRP/Ti w/CSK ) • Drill Qty 3 Locations (ID 11) • Drill Qty 4 Locations (ID 12) • Step 3: GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 2 Locations (ID 13) • Drill Qty 1 Locations (ID 14) • Drill Qty 2 Locations (ID 15) • Drill Qty 1 Locations (ID 16) • Step 4: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 5 Locations (ID 17) LH PAX 2 1 3 2 4 3 17 4 1744 1794 6 5 7 6 8 7 KEEL 9 8 17 9 12 11 AFT 12 11 2 1 17 10 2 1 12 11 13 12 17 13 15 14 15 16

  5. P3 15 14 • Step 1: Use WHITE Setup (3/8” CFRP/Ti w/CSK) • Drill Qty 5 Locations (ID 1) • Drill Qty 6 Locations (ID 2) • Drill Qty 4 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Step 2: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 3 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 1 Location (ID 8) • Step 3: Use WHITE Setup (3/8” CFRP/Ti w/CSK) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 9) • Step 4: Use PINK Setup (3/8” CFRP/Ti Drill Only) • Drill Qty 3 Locations (ID 10) • Step 5: Use BLACK Setup (1/4” CFRP/Ti w/CSK) • INSTALL APPROPRIATE CENTRIX PIN AT (ID 13) • Drill Qty 1 Location (ID 11) • Drill Qty 2 Locations (ID 12) • Drill Qty 2 Location (ID 13) • Drill Qty 2 Locations (ID 14) • Drill Qty 1 Location (ID 15) LH PAX 14 13 12 13 11 12 1744 1794 8 7 6 7 3 2 KEEL 2 1 9 1 2 1 AFT 2 3 Complete ID 1-8, THEN do P9 Entirely and Resume P3 at ID 9 10 3 5 4 5 4 10 3 10 2 1 2 9 1 6 6

  6. P12 15 15 LH PAX • Step 1: Use WHITE Setup (3/8” CFRP/Ti w/CSK) • Drill Qty 3 Locations (ID 1) • Drill Qty 3 Locations (ID 2) • Drill Qty 1 Location (ID 3) • Step 2: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 5 Locations (ID 4) • Drill Qty 6 Locations (ID 5) • Drill Qty 4 Locations (ID 6) • Drill Qty 3 Locations (ID 7) • Drill Qty 1 Location (ID 8) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 4 and ID 1 • Drill Qty 1 Locations (ID 9) • Step 3: Use WHITE Setup (3/8” CFRP/Ti w/CSK) • Drill Qty 3 Locations (ID 10) • Drill Qty 1 Location (ID 11) • Drill Qty 1 Location (ID 12) • Step 4: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 4 Locations (ID 14) • Step 5: Use BLACK Setup (1/4” CFRP/Ti w/CSK) • Drill Qty 2 Locations (ID 15) 6 5 5 4 3 2 2 1744 1794 1 1 10 2 1 KEEL 5 4 14 5 7 AFT 6 11 10 12 10 14 7 14 6 4 5 9 4 4 5 14 6 8 7

  7. P5 2 1 LH PAX 1 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 5 Locations (ID 1) • Drill Qty 4 Locations (ID 2) • Drill Qty 3 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 4 Locations (ID 5) • Drill Qty 4 Locations (ID 6) • Drill Qty 3 Locations (ID 7) • Drill Qty 3 Locations (ID 8) • Drill Qty 3 Locations (ID 9) • Drill Qty 1 Location (ID 10) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 11) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill ONLY) • Drill Qty 4 Locations (ID 12) 11 12 1 3 2 4 1744 1794 3 5 4 6 5 KEEL 7 6 12 7 9 8 AFT 10 9 9 8 8 7 12 6 6 5 5 4 4 3 12 2 11 1 1 2

  8. P4 12 • Step 1: Use WHITE Setup (3/8” CFRP/Ti w/CSK ) • Step 2: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 4 Locations (ID 9) • Drill Qty 3 Locations (ID 10) • Drill Qty 2 Locations (ID 11) • Drill Qty 2 Locations (ID 12) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled by ID 9 and ID 1 • Drill Qty 1 Locations (ID 13) • Step 3: Use WHITE Setup (3/8” CFRP/Ti w/CSK ) • Drill Qty 1 Location (ID 14) • Step 4: Use BLACK Setup (1/4” CFRP/Ti w/CSK) • Drill Qty 2 Locations (ID 15) • Step 5: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 2 Locations (ID 16) • Step 6: Use PINK Setup (3/8” CFRP/Ti Drill Only) • Drill Qty 3 Locations (ID 17) 11 LH PAX 16 • Drill Qty 3 Locations (ID 1) • Drill Qty 3 Locations (ID 2) • Drill Qty 2 Locations (ID 3) • Drill Qty 1 Location (ID 4) • Drill Qty 1 Location (ID 5) • Drill Qty 1 Location (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 1 Location (ID 8) 10 13 9 9 10 1744 10 1794 11 16 12 KEEL 8 7 7 6 AFT 17 5 17 4 17 3 3 2 2 1 1 14 2 1 9 9 15 15

  9. Prior Work Required P10 LH PAX • Step 1: Verify Prior Work Completed • Ensure P12 (Lower Aft Edge) Operations Complete w/ Adjacent Clamp at Location A • Step 2:Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Location (ID 1) • Step 3: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 1 and ID 2 • Step 4:Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Step 5: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 11 and ID 12 • Step 6: Use BLACK Setup (1/4” CFRP/Ti w/ CSK) • Drill Qty 1 Location (ID 12) • Drill Qty 2 Locations (ID 13) • Step 7: Use BLUE Setup (1/4”CFRP w/CSK ) • Drill Qty 2 Locations (ID 14) • Drill Qty 2 Locations (ID 15) • Drill Qty 2 Locations (ID 16) • Drill Qty 2 Locations (ID 17) • Drill Qty 2 Locations (ID 18) • Drill Qty 2 Locations (ID 19) • Drill Qty 1 Location (ID 20) • Drill Qty 1 Location (ID 21) • Step 8 : Drill per Appendix G • Drill Qty 1 Location (ID22) 1744 1794 KEEL AFT • Drill Qty 2 Locations (ID 2) • Drill Qty 2 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 1 Location (ID 5) • Drill Qty 1 Location (ID 6) • Drill Qty 1 Location (ID 7) • Drill Qty 1 Location (ID 8) • Drill Qty 1 Location (ID 9) • Drill Qty 1 Location (ID 10) • Drill Qty 1 Location (ID 11) 1 2 3 A 4 13 12 2 3 4 19 5 17 6 15 7 8 22 9 10 15 11 17 19 18 21 16 13 14 14 16 18 20

  10. P11 LH PAX • Step 1:Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 2 Locations (ID 1) • Step 2: Install 2 ST-XXXX-XX Adj Clamp Load Washers Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) Drill in the following sequence. • Drill Qty 2 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 6 Locations (ID 4) • Drill Qty 6 Locations (ID 5) • Drill Qty 5 Locations (ID 6) • Drill Qty 6 Locations (ID 7) • Drill Qty 7 Locations (ID 8) • Drill Qty 4 Locations (ID 9) • Drill Qty 3 Locations (ID 10) • Step 4: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 7 and ID 11 • Step 5: Use GREEN Setup (5/16” CFRP/Ti w/ CSK) • Drill Qty 1 Location (ID 11) • Drill Qty 1 Location (ID 12) • Step 6: Use PURPLE Setup (5/16” CFRP/CFRP Drill Only) • Drill Qty 8 Locations (ID 13) • Step 7 : Drill per Appendix G • Drill Qty 2 Locations (ID 14) 1744 1794 KEEL AFT 13 10 9 8 7 13 13 14 1 3 4 5 13 8 10 12 9 8 8 7 7 13 6 5 5 4 3 4 3 1 2 14 3 13 4 6 5 13 6 8 7 9 11 8 13 7 6 5 4 3 2 3 4 5 6 7 8 9 10

  11. Prior Work Required P9 LH PAX • Step 1: Verify Prior Work Completed • Ensure P3 (Lower Fwd Edge) Operations Complete w/ Adjacent Clamp at Location A • Step 2: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Location (ID 1) • Drill Qty 1 Location (ID 2) • Drill Qty 1 Location (ID 3) • Drill Qty 1 Location (ID 4) • Step 3: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 4 and ID 5 • Step 4: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Location (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 1 Location (ID 9) • Drill Qty 1 Location (ID 10) • Drill Qty 1 Location (ID 11) • Drill Qty 1 Location (ID 12) • Step 5: Use BLUE Setup (1/4”CFRP/CFRP w/CSK ) • Ensure Pin Installed at Pre-existing Thru Hole (ID 25) • Drill Qty 2 Locations (ID 13) • Drill Qty 2 Locations (ID 14) • Drill Qty 2 Locations (ID 15) • Drill Qty 2 Locations (ID 16) • Drill Qty 2 Locations (ID 17) • Continued… 1744 1794 KEEL AFT 17 15 13 15 13 17 4 16 3 14 2 25 1 14 16 12 A 11 10 9 8 7 6 5 6 7 8

  12. P9 (…Continued) • Step 5: Use BLUE Setup (1/4” CFRP/CFRP w/CSK ) • Drill Qty 2 Locations (ID 18) • Drill Qty 1 Location (ID 19) • Drill Qty 1 Location (ID 20) • Drill Qty 1 Location (ID 21) • Step 6: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 18 and ID 22 • Step 7: Use BLACK Setup (1/4” CFRP/Ti w/ CSK) • Drill Qty 1 Location (ID 22) • Drill Qty 2 Locations (ID 23) • Step 8 : Drill per Appendix G • Drill Qty 1 Locations (ID 24) • Drill Qty 1 Locations (ID 25) LH PAX 1744 1794 KEEL AFT 21 19 23 22 20 18 24 25 23 18

  13. Prior Work Required P7 • Step 1: Verify Prior Work Completed • Ensure P4 (Upper Aft Edge) Operations Complete w/ Adjacent Clamp at Location A • Step 2: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Location (ID 1) • Drill Qty 1 Location (ID 2) • Drill Qty 1 Location (ID 3) • Step 3: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 3 and ID 4 • Step 4: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 1 Location (ID 7) • Drill Qty 1 Location (ID 8) • Drill Qty 1 Location (ID 9) • Drill Qty 1 Location (ID 10) • Step 5: Use BLUE Setup (1/4” CFRP w/CSK ) • Drill Qty 1 Location (ID11) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 11 • Step 6: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 25 and ID 12 • Step 7: Use BLUE Setup (1/4” • CFRP/CFRP w/CSK ) • Drill Qty 1 Location (ID 12) • Drill Qty 1 Location (ID 13) • Drill Qty 1 Location (ID 14) • Drill Qty 1 Location (ID 15) • Drill Qty 1 Location (ID 16) • Drill Qty 1 Location (ID 17) • Drill Qty 1 Location (ID 18) • Drill Qty 1 Location (ID 19) • Drill Qty 1 Location (ID 20) • Drill Qty 1 Location (ID 21) • Drill Qty 1 Location (ID 22) • Drill Qty 1 Location (ID 23) • Drill Qty 1 Location (ID 24) • Step 8 : Drill per Appendix G • Drill Qty 1 Locations (ID 25) LH PAX 1744 1794 KEEL AFT 6 5 4 15 13 25 A 17 19 21 23 5 6 7 8 9 10 11 14 12 16 18 20 22 24 1 2 3

  14. P8 LH PAX • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 4 Locations for (ID 1) • Step 2: Install 2 ST-XXXX-XX Adj Clamp Load Washers Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 2 Locations (ID 2) • Drill Qty 8 Locations (ID 3) • Step 4: Use PURPLE Setup (5/16” CFRP/CFRP Drill Only) • Drill Qty 4 Locations (ID 4) • Step 5: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 8 Locations (ID 5) • Drill Qty 6 Locations (ID 6) • Drill Qty 6 Locations (ID 7) • Drill Qty 5 Locations (ID 8) • Step 6: Use PURPLE Setup (5/16” CFRP/CFRP Drill Only) • Drill Qty 4 Locations (ID 9) • Step 7: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 7 Locations (ID 10) • Drill Qty 6 Locations (ID 11) • Drill Qty 2 Locations (ID 12) • Step 8 : Drill per Appendix G • Drill Qty 2 Locations (ID 13) 1744 1794 KEEL AFT 11 10 9 5 4 3 2 3 4 5 6 7 8 9 10 11 11 10 9 7 6 5 4 3 2 3 4 5 9 10 11 12 10 8 7 6 5 3 1 13 1 3 5 6 7 8 10 11 12 11 10 8 7 6 5 3 1 13 1 3 5 6 7 8

  15. P6 LH PAX • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Location (ID 1) • Drill Qty 1 Location (ID 2) • Step 2: Install ST-XXXX-XX Adj Clamp Load Washer Between ID 2 and ID 3 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Drill Qty 1 Location (ID 6) • Drill Qty 1 Location (ID 7) • Drill Qty 1 Location (ID 8) • Drill Qty 1 Location (ID 9) • Drill Qty 1 Location (ID 10) • Drill Qty 1 Location (ID 11) • Step 5: Use BLUE Setup (1/4” CFRP w/CSK ) • Drill Qty 2 Locations (ID12) • Drill Qty 2 Locations (ID 13) • Drill Qty 2 Locations (ID 14) • Drill Qty 1 Location (ID 15) • Drill Qty 1 Location (ID 16) • Drill Qty 1 Location (ID 17) • Drill Qty 1 Location (ID 18) • Drill Qty 1 Location (ID 19) • Drill Qty 1 Location (ID 20) • Drill Qty 1 Location (ID 21) • Drill Qty 1 Location (ID 22) • Drill Qty 1 Location (ID 23) • Drill Qty 1 Location (ID 24) • Drill Qty 1 Location (ID 25) • Step 8 : Drill per Appendix G • Drill Qty 1 Location (ID 26) • Drill Qty 1 Location (ID 27) 1744 1794 KEEL AFT 24 22 20 18 16 14 12 12 10 11 9 8 7 6 5 4 3 4 5 25 23 21 19 17 15 13 27 14 13 2 1 26

  16. BCD (VIEW LOOKING INWARD) KEEL AFT

  17. P9 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 4 Locations (ID 1) • Drill Qty 6 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 4 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 1 Locations (ID 7) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 4 Locations (ID 8) 2 BCD 1 8 8 8 8 1 2 1719 1670 2 3 3 KEEL 4 4 5 5 6 AFT 6 5 5 4 4 3 3 2 2 1 3 7 1 3 2

  18. P5 1 2 BCD 6 1 1 2 2 3 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 6 Locations (ID 1) • Drill Qty 7 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 6) 1719 1670 3 4 4 KEEL 5 4 5 AFT 3 4 2 3 1 2 1 6 2 1 3 2 3

  19. P4 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 4 Locations (ID 1) • Drill Qty 5 Locations (ID 2) • Drill Qty 4 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 3 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 1 Locations (ID 7) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill ONLY) • Drill Qty 2 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • Step 3: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 2 Locations (ID 11) 1 BCD 2 1 7 2 1 1719 1670 3 2 4 3 KEEL 5 4 6 AFT 5 6 4 5 3 4 2 3 1 2 9 8 9 8 11 11

  20. P3 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 4 Locations (ID 1) • Drill Qty 5 Locations (ID 2) • Drill Qty 4 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 4 Locations (ID 5) • Drill Qty 4 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 1 Locations (ID 8) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill ONLY) • Drill Qty 4 Locations (ID 9) 2 1 BCD 9 9 9 9 1 2 2 1719 1670 3 3 4 KEEL 4 5 5 6 AFT 6 7 7 6 6 5 5 4 4 3 3 2 2 1 1 8

  21. P2 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 5 Locations (ID 1) • Drill Qty 6 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 5 Locations (ID 4) • Drill Qty 3 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 2 Locations (ID 7) BCD 1 7 2 1 3 2 4 3 1719 1670 5 4 KEEL 6 5 6 5 5 AFT 4 4 3 3 2 2 1 1 7 2 1 3 2 4 3

  22. P1 BCD 1 14 • Step 1: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 3 Locations (ID 1) • Drill Qty 3 Locations (ID 2) • Drill Qty 2 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • Drill Qty 2 Locations (ID 10) • Drill Qty 2 Locations (ID 11) • Drill Qty 2 Locations (ID 12) • Drill Qty 1 Locations (ID 13) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 1 Locations (ID 14) • Step 2: Use RED Setup (5/16” CFRP/Ti Drill Only) • Drill Qty 4 Locations (ID 15) 2 1 3 2 4 3 1719 1670 4 5 KEEL 6 5 7 6 8 7 AFT 9 8 9 10 10 11 11 12 12 13 15 15 15 15 2 1

  23. P11 • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Locations (ID 1) • Step 2: Install ST-XXXX-XX Adjacent Clamp Load Washer Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Locations (ID 2) • INSTALL FULL SIZE INDEX PIN(s) in Location(s) Drilled in ID 1 • Drill Qty 3 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • Drill Qty 2 Locations (ID 10) • Drill Qty 2 Locations (ID 11) • Drill Qty 2 Locations (ID 12) • Drill Qty 2 Locations (ID 13) • Step 4 : Drill per Appendix G • Drill Qty 1 Location (ID 14) BCD 1719 1670 KEEL AFT 10 11 12 13 14 1 9 4 6 8 3 5 7 10 11 12 13 5 9 4 6 8 2 3 3 7

  24. P12 Prior Work Required • Step 1: Verify Prior Operations • Ensure P9 (Lower-Aft BCD Edge Frame) Operation Complete w/ Adjacent Clamp at Location A • Step 2: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 1 Locations (ID 1) • Step 3: Install ST-XXXX-XX Adjacent Clamp Load Washer Between ID 1 and ID 2 • Step 4: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) BCD 1719 1670 KEEL • Drill Qty 2 Locations (ID 22) • Drill Qty 2 Locations (ID 23) • Drill Qty 2 Locations (ID 24) • Drill Qty 2 Locations (ID 25) • Drill Qty 2 Locations (ID 26) • Drill Qty 2 Locations (ID 27) • Drill Qty 2 Locations (ID 28) • Drill Qty 2 Locations (ID 29) • Drill Qty 1 Locations (ID 30) • Drill Qty 2 Locations (ID 12) • Drill Qty 2 Locations (ID 13) • Drill Qty 2 Locations (ID 14) • Drill Qty 2 Locations (ID 15) • Drill Qty 2 Locations (ID 16) • Drill Qty 2 Locations (ID 17) • Drill Qty 2 Locations (ID 18) • Drill Qty 2 Locations (ID 19) • Drill Qty 2 Locations (ID 20) • Drill Qty 2 Locations (ID 21) • Drill Qty 2 Locations (ID 2) • Drill Qty 2 Locations (ID 3) • Drill Qty 2 Locations (ID 4) • Drill Qty 2 Locations (ID 5) • Drill Qty 2 Locations (ID 6) • Drill Qty 2 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • Drill Qty 2 Locations (ID 10) • Drill Qty 2 Locations (ID 11) AFT 4 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 A 6 7 8 9 2 3 4 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

  25. P10 • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 3 Locations (ID 1) • Step 2: Install ST-XXXX-XX Adjacent Clamp Load Washer • Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 2 Locations (ID 2) • Drill Qty 3 Locations (ID 3) • Drill Qty 3 Locations (ID 4) • Drill Qty 3 Locations (ID 5) • Step 4: Install ST-XXXX-XX Adjacent Clamp Load Washer Between ID 5 and ID 6 • Step 5: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 4 Locations (ID 6) • Drill Qty 5 Locations (ID 7) • Drill Qty 3 Locations (ID 8) • Drill Qty 2 Locations (ID 9) • Step 6 : Drill per Appendix G • Drill Qty 1 Location (ID 10) BCD 1719 1670 KEEL AFT 1 2 3 4 5 6 7 7 6 4 3 1 10 1 5 9 8 7 7 8 9 8 7 6 6 5 4 3 2

  26. P8 BCD • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 3 Locations (ID 1) • Step 2: Install ST-XXXX-XX Adjacent Clamp Load Washer Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 5 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 5 Locations (ID 4) • Drill Qty 4 Locations (ID 5) • Drill Qty 1 Locations (ID 6) • Step 4 : Drill per Appendix G • Drill Qty 2 Locations (ID 7) 1719 1670 KEEL AFT 3 2 3 4 5 6 5 4 3 2 3 4 5 2 7 3 5 3 2 7 1 2 4 4 1 1

  27. P6 • Step 1: Use YELLOW Setup (5/16” CFRP w/CSK) • Drill Qty 4 Locations (ID 1) • Drill Qty 6 Locations (ID 2) • Drill Qty 6 Locations (ID 3) • Drill Qty 6 Locations (ID 4) • Drill Qty 5 Locations (ID 5) • Drill Qty 4 Locations (ID 6) • Drill Qty 4 Locations (ID 7) • Drill Qty 4 Locations (ID 8) • Drill Qty 3 Locations (ID 9) • Drill Qty 4 Locations (ID 10) • Drill Qty 4 Locations (ID 11) • Drill Qty 3 Locations (ID 12) • Drill Qty 1 Locations (ID 13) • Step 2: Use GREEN Setup (5/16” CFRP/Ti w/CSK) • Drill Qty 1 Locations (ID 14) • Step 3 : Drill per Appendix G • Drill Qty 1 Location (ID 15) BCD 1719 1670 KEEL AFT 8 9 1 2 3 4 6 7 9 8 7 6 3 1 15 1 2 3 4 10 2 5 11 11 5 4 12 10 27 2 3 4 5 7 8 5 6 4 9 10 11 8 7 6 2 3 12 3 2 5 4 1 13 12 11 14 10

  28. P7 BCD • Step 1: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 3 Locations (ID 1) • Step 2: Install 2 ST-XXXX-XX Adjacent Clamp Load Washer Between ID 1 and ID 2 • Step 3: Use YELLOW Setup (5/16” CFRP/CFRP w/CSK) • Drill Qty 4 Locations (ID 2) • Drill Qty 4 Locations (ID 3) • Drill Qty 4 Locations (ID 4) • Drill Qty 4 Locations (ID 5) • Drill Qty 4 Locations (ID 6) • Drill Qty 3 Locations (ID 7) • Drill Qty 2 Locations (ID 8) • Drill Qty 1 Locations (ID 9) • Step 4 : Drill per Appendix G • Drill Qty 1 Location (ID 10) 1719 1670 KEEL AFT 2 3 4 5 6 7 8 9 8 7 6 5 4 3 2 5 6 7 6 5 4 3 4 1 2 3 2 1 10 1

More Related