PTIT for DCU of OINDP: Approaches to Resolution of Identified Issues

PTIT for DCU of OINDP: Approaches to Resolution of Identified Issues. Wallace P. Adams, Ph.D. OPS/IO Advisory Committee for Pharmaceutical Science 21 October 2003 Rockville, MD. Outline. Current DCU and SCU Tests Parametric Tolerance Interval Test (PTIT) Consensus Points OPS Issues

andrew
Download Presentation

PTIT for DCU of OINDP: Approaches to Resolution of Identified Issues

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PTIT for DCU of OINDP:Approaches to Resolution of Identified Issues Wallace P. Adams, Ph.D. OPS/IO Advisory Committee for Pharmaceutical Science 21 October 2003 Rockville, MD

  2. Outline • Current DCU and SCU Tests • Parametric Tolerance Interval Test (PTIT) • Consensus Points • OPS Issues • The “Gap” and the Quality Assurance Constraint • Proposed Resolutions

  3. Two Guidances • Metered Dose Inhaler (MDI) and Dry Powder Inhaler (DPI) Drug Products - CMC Documentation (Draft, October 1998) • Nasal Spray and Inhalation Solution, Suspension, and Spray Drug Products - CMC Documentation (Final, July 2002)

  4. The DCU and SCU Issue • DCU (dose content uniformity) • SCU (spray content uniformity) • Uniformity of metered doses from an MDI, DPI or nasal spray • within a container for multiple dose products • among containers • among batches

  5. Current DCU and SCU Tests • Nonparametric (with a parametric element, the sample mean restriction) • Single dose and multi-dose products

  6. Present DCU and SCU Tests:DCU Through Container Lifefor Multi-dose Products (Tier 1) • MDIs • DCU measured through container life • DPIs (device-metered) • Same as for MDIs • Nasal sprays • SCU measured at B and E lifestages • for each of 10 containers

  7. FDA DCU and DCU TCL Tests 1 Metered Dose Inhaler and Dry Powder Inhaler CMC Draft Guidance, Oct 1998 2 Nasal Spray, Inhalation Solution, Suspension, and Spray Drug Products CMC Guidance, July 2002 3 Both DCU and TCL tests apply to MDIs and device-metered DPIs

  8. A Parametric Tolerance Interval Approach General form of the criterion: Y  kS where: Y = absolute value (LC - sample mean) k = a tolerance interval constant s = sample std dev RL Williams et al, Pharm Res, 2002; 19:359-66

  9. A Parametric Tolerance Interval • Intended to control ranges of specified coverage, e.g., • 85% of the doses within • 75 - 125% of LC at • 95% confidence • We therefore specify1 • minimum proportion of the batch that should fall within the limits (coverage) • acceptable tolerance limits (target interval) • degree of confidence 1 RL Williams et al, Pharm Res, 2002; 19:359-66

  10. Consensus Point # 1 • Acceptability of the PTIT statistical approach conceptually • Based on a statistical hypothesis test • Facilitates risk communication to practitioners and patients/consumers • Places constraints on both maximum sample SD and sample mean

  11. Consensus Point # 2 • Elimination of the Zero Tolerance Criterion (ZTC) • ZTC: • prohibits any dose in the sample from falling outside the stated interval • reduces the likelihood that a unit in the batch will deviate substantially from LC • ZTC conflicts with the producer’s choice of sample size • for normal distributions, PTIT preserves the specified alpha level without the ZTC

  12. OPS Issue # 1 • Robustness to  level • Non-normal distributions • for certain data distributions,  can substantially exceed 0.05 • do non-normal distributions exist for some OINDP products and batches? • Estimated consumer risk of IPAC-RS proposal exceeds 0.05 • by a small amount, e.g., 0.051, for normally distributed data • at certain deviations in batch mean from LC • Approaches to assuring  0.05? •   0.05,   0.025?

  13. Maximum Type I Error is 5.1% (occurs for smallest sample size at mean deviation of ±9 %LC) Sample size Normal distribution at limiting quality (85% coverage of 100±25% LC) B. Olsson, ACPS Meeting, 13 Mar 2003

  14. Non-normal Distribution IPAC-RS Report, 15 Nov 2001, p. 68

  15. OPS Issue # 2 • Definition of limiting quality • 85% of doses in the batch within 75 - 125% of label claim? • 85% of doses within 80 - 120% of label claim? • 90% of doses within 75 - 125% of label claim? • 90% of doses within 80 – 120% of label claim? • other options? • The “Gap” widens as the sample size increases • The “Gap” tends to widen as the mean deviates increasingly from 100% LC • The “Gap” narrows as the coverage increases and the target interval narrows

  16. IPAC-RS Report, 15 Nov 2001, p. 12

  17. PTI Test, Multi-Dose Products IPAC-RS Report, 15 Nov 2001, p. 25

  18. Comparison of Operating Characteristic Curves 21 “Gap” LQ FDA test: as in Draft MDI/DPI Guidance • Consumer protection (Limiting Quality, LQ) same • PTI test’s curve is sharper (narrowed area of uncertainty) • Fewer acceptable batches rejected (lower producer risk) • “Gap”: Fewer rejections does not mean lower quality of accepted batches (see simulated production illustration below) B. Olsson, ACPS Meeting, 13 Mar 2003

  19. OPS Issue # 3 • Robustness in the Producer Protection Region • does the PTIT become more conservative for non-normal distributions?

  20. IPAC-RS Report, 15 Nov 2001, p. 68

  21. The Quality Assurance Constraint:An Additional Limiting Quality • The “Gap” exists between the “FDA curve” and the PTIT curves for all limiting qualities • At a 90% acceptance probability, the PTIT allows greater batch variability than does the “FDA curve” for three of four limiting qualities • OPS desires to limit the magnitude of the “Gap”

  22. Operating Characteristic Curve Producer protection region (changes with sample size) 100 90 80 Area of uncertainty 70 60 Probability to Accept (%) Quality Assurance Region (fixed) 50 40 30 20 10 5% 0 Consumer protection region Variability (either standard deviation at a given batch mean or coverage) Y. Tsong, ACPS Meeting, 13 Mar 2003. Slide adapted from B. Olsson, 13 Mar 2003

  23. FDA Working Group to Determine(Over the Next Six Months) Limiting Quality Standard • Confirm appropriateness of  0.05 • Establish appropriate “Quality Assurance Constraint” (at 90% acceptance probability) • To include FDA clinical recommendations

  24. A Proposed Resolution • Adopt the PTIT approach • Left side of Operating Characteristic (OC) curve to be approximately superimposable with the FDA OC curve, with emphasis on the 90% acceptance probability region

  25. Craig Bertha, Ph.D. Alan Carlin Walter Hauck, Ph.D. Ajaz Hussain, Ph.D. Guirag Poochikian, Ph.D. Donald Schuirmann Meiyu Shen, Ph.D. Edward Sherwood Yi Tsong, Ph.D. Marilyn Welschenbach, Ph.D. Helen Winkle Acknowledgments