History of Conditioning Methods

History of Conditioning Methods. 1970s to early 80s: Time of Manufacture RIC/TIMA 281-1 Uniform Conditioning Period – 6 months Practical Comparative ASTM C 1289: PIMA 101 or 90 days @ 140 °F – 1987 ORNL Joint project (1992) – PIMA, NRCA, DOE, EPA ASTM C1303

anthea
Download Presentation

History of Conditioning Methods

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. History of Conditioning Methods • 1970s to early 80s: Time of Manufacture • RIC/TIMA 281-1 • Uniform Conditioning Period – 6 months • Practical • Comparative • ASTM C 1289: PIMA 101 or 90 days @ 140 °F – 1987 • ORNL Joint project (1992) – PIMA, NRCA, DOE, EPA • ASTM C1303 • Accelerated aging through slicing and scaling • Validation – R-value of lab samples matched in situ polyiso

  2. History of Conditioning Methods • LTTR (Long-Term Thermal Resistance) 2001 • – 15 year time weighted average • 1995: ASTM C 1303 • December 2000: CAN/ULC-S770 • Effective January 1, 2003 • LTTR based on CAN/ULC –S770 approved as an addition to • ASTM C 1289-02 • R-Value of 6 Per Inch – increased with thicker boards • Extensive Educational Programs • Users • Specifiers • Designers

  3. R-Values are changing – Nothing More. • Same Product • Same Physical Properties • Same Approvals • Polyiso Remains The Highest R-Value per Inch of any Rigid Board Insulation • Same FM and UL Approvals • PIMA Quality Mark Program

  4. New Values The Polyisocyanurate Insulation Manufacturers Association’s (PIMA) recommendation for a Class 1 roof is suggested to have a designed R-value of 5.7 per inch. PIMA also recommends that you check with the manufacturer for their 2014 published LTTR values.

  5. An Easy Comparison Same Product… Different Testing Method = New Results 38 MPG 30 MPG

  6. Hunter Panels - Ad • Ad/insert in September 2013 • Professional Roofing • Roofing Contractor • RCI Interface

  7. New R value cards available • Inserted into: • Professional Roofing Roofing Contractor • Available in Bulk

  8. Email Blast on Tuesday 8/13/2013 • To reps, OEM’s and customer base • Please send via email too, as not all our customers have opted into our email list • Available in special section of our website

  9. Special Section on our Website

  10. Special Web Section • TOOLS INCLUDED: • This PPT Presentation • Frequently Asked Q’s • Submittal Documents by Product • Packaging/Loading Charts • with all R-Values by Product

  11. Special Web Section • TOOLS INCLUDED: • Hunter Ad • Hunter Email Blast • Professional Roofing – • NRCA Mark Graham Article • PIMA Ad • PIMA Article • Press Releases

  12. NEW 2014 H-Shield Literature

  13. NEW 2014 H-Shield Loading and Packaging Chart

  14. Frequently Asked Questions and Answers

  15. Frequently Asked Questions and Answers

  16. NRCA Mark Graham Article - RFI

  17. For more information ww.hpanels.com 888-746-1114