An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vacuum Tube Lifters Basic Overview

  2. Vacuum Lifting

  3. How to quote a Vacuum Tube Lifter You may also add ancillary items such as Universal Joint or Lower Rotary Coupling

  4. Typical System Layout

  5. Typical System Layout

  6. Typical System Layout

  7. Typical System Layout

  8. Tube Assembly Vacuum 360o Rotary Safety Plate Support Rope Vacuum

  9. Lift Tube Range - MiniLifter (ML) Note: Capacities shown do not include end effector or ancillary items e.g. Universal Joint

  10. Lift Tube Range - Pal-U-Lift (PL) Note: Capacities shown do not include end effector or ancillary items e.g. Universal Joint

  11. Lift Tube Range - High Capacity (HCL) Note: Capacities shown do not include end effector or ancillary items e.g. Universal Joint

  12. Typical System Layout

  13. MiniLifter (ML) Control Valves – partial listing ML-TV Trigger type ML-HV Horizontal type ML-FEHV Flexible extension to horizontal handle

  14. Pal-U-Lift (PL) Control Valves – partial listing PL-SPL Stay-Put PL-SLL Spring Loaded PL-SPT Throttle type PLE-SPL Extended PL-SLL Flexible Extended

  15. High Capacity (HCL) Control Valves – partial listing HCLE-SPL Extended with Stay-Put HCLFE-SLL Flexible Extended with Stay-Put

  16. Typical System Layout

  17. Safety Ratios – cups are sized to match tube diameter safety ratio of 2.5:1 for horizontal and 4.0:1 for vertical

  18. Ancillary Items – partial listing Lower Rotary Universal Joint Angle Adaptor Angle Adaptor c/w Gas Strut

  19. Ancillary Items – partial listing Lift-Off fitted to PL-SPL Control Handle Lift-Off fitted to a ML Control Handle

  20. Trolley Pin Height Checking Compacted Height of SLTA or MLTA assembly + Ancillary + Controls + End Effector + 67 inches (stroke) to give o/a height for trolley pin elevation (add 2 inches to total to give clearance above floor)