An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Proposed Change to CLCT Pretrigger • Proposal: • Study changing from 2- to 3-layer pretrigger for CLCT • Study the same for ALCT • Possible benefits: • Lower rate of CLCT pretriggers lowers deadtime at high luminosity • Lower rate of CLCT pretriggers decreases SCA occupancy • The change MAY improve CLCT efficiency • The change MAY improve CLCT timing • Cartoon: highly angled track: 2-layer but not 3-layer pretrigger Also will cut away pretriggers from 2-layer neutron hits CSC DPG/Commissioning Meeting Jay Hauser

  2. CLCT Efficiency • From Elog entry 59743 (20-May-09): • “Past Slice Test studies (August 2007) indicated that this may improve cathode trigger efficiency by a small fraction of a percent. A plot of this effect is attached.” Disclaimer: ‘the "efficiencies" shown in the plot attached use the CLCT in n-layer trigger mode, so that when the ALCT fires, any combination of n layers hit will trigger the CLCT. This is a way of getting an algorithmic efficiency that can be gleaned from TMB counters information online. The slight loss of efficiency (on the order of 1%) may be largely due to hits at the ends of the wires (last 5mm on each end), where cathode strip coverage within the chamber is incomplete.’ CSC DPG/Commissioning Meeting Jay Hauser

  3. High-luminosity effect • Electronics effect of a CLCT pretrigger: • Causes SCA blocks to be frozen in CFEBs • Causes cathode trigger deadtime of a few bx  trigger ineff. • Plot from Khotilovich May 13-15, 2009 CMS upgrade workshop, 400 pile-up events/bx from L=1035/cm2s: Efficiency loss is significant for ME1/1 Note: the simulation of CLCT-ALCT matching has been improved (Valuev) since this plot CSC DPG/Commissioning Meeting Jay Hauser

  4. ALCT and CLCT Details • ALCT and CLCT both work the same way: • Hits arrive over 2-3 bx due to drift time variations. • Hits are made “persistent” for several bunch crossings. • Coincidence level>=2 layers in a pattern (“pretrigger”) defines TIME. • Fixed “drift delay”, then coincidence level>=4 layers in a pattern validates the LCT (“trigger”) and defines SPACE position • Current parameters: • (same for all chambers) Too long, 4 bx better matched to 2 bx drift delay CSC DPG/Commissioning Meeting Jay Hauser

  5. Test runs: 100K events each in quick succession CLCT 2/4, and ALCT 2/4 planes (baseline) Same as previous but change clct_hit_persist from 64 bx CLCT 3/4, and ALCT 2/4 planes (CLCT changes) CLCT 3/4, and ALCT 2/4 planes (ALCT changes) CLCT 3/4, and ALCT 3/4 planes (both change) Should NOT measurably affect CLCT or ALCT or matched LCT rates with cosmic rays Study performance with DQM and offline ALCT-CLCT relative timing accuracy CLCT efficiency Etc. Must then agree on such a change Trivial to implement – parameters in XML configuration files Some tuning possible: CLCT will be later relative to ALCT by ~6 ns (0.25 bx). Should not affect LCT timing to SP. Detailed Proposal CSC DPG/Commissioning Meeting Jay Hauser

  6. Update June 2: Test run data collected 26-May-09 • About 200K events per run • Run 97511 ALCT=2, CLCT=2 layers baseline • Run 97557 change to CLCT hit persistence=4 bx • Run 97563 ALCT=2, CLCT=3 layers • Run 97568 ALCT=3, CLCT=2 layers • Run 97574 ALCT=3, CLCT=3 layers • Run 97577 ALCT=2, CLCT=2 return to baseline, long run • Next slide: results from offline CSC DQM for one chamber • ME-3/2/28 at bottom so “collision-like” muon angles CSC DPG/Commissioning Meeting Jay Hauser

  7. ALCT: 2 CLCT: 2 ALCT: 2 CLCT: 3 ALCT: 3 CLCT: 2 ALCT: 3 CLCT: 3 ALCT-CLCT timing with pretrigger layers 2, 3 CSC DPG/Commissioning Meeting Jay Hauser