Islanding Detection can be classified into passive methods, which look for events on the grid, and active methods, testing the network from the inverter or the grid distribution point. There are also methods that the utility can use to detect the conditions that would deliberately upset those conditions in order to power down the inverters.

Download Presentation

Solar Generator Connection Issues | BCJ Controls | Secondary Protection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Issues when Connecting a Solar Generator to the Grid BCJ Controls - Protection Specialists

  2. Issues when Connecting a Solar Generator to the Grid • There are a number of potential issues that can be encountered when connecting an embedded generator to the grid, and they depend largely upon the particular location and set up of the proposed project. If you suspect that any of the issues below may apply to your project you may want to get in contact with us for technical support during the planning and design phases.

  3. Power Export Into The Electricity Network • If a generation project is planning on exporting energy into the distribution network it may make the grid connection more complicated, and the DNSP (Aka Supply Authority) may require a higher standard of compliance. This is because of the impact that the export of extra power can have on the network.

  4. Generator Stability while Connected to the Network • This issue can generally be overcome with the installation of a pole slip protection relay which disconnects the generator from the network if the power generator is unstable.

  5. Fault LevelProblems • In built up areas there are problems with the very high levels of fault current that can occur under fault conditions. This is due to the specific network configurations. The preferred method to overcome fault level issues is the installation of a fault current limiting breaker in the systems setup, though this can become an expensive addition for some projects.

  6. Steady State Voltage Levels • The connection of an embedded generator can impact on the voltage levels of the connected network. HV distribution networks have a degree of dynamic voltage control, however, low voltage networks are unable to regulate this dynamically. This means that changes to the high voltage network can impact the low voltage network and studies may be required to make sure that the low voltage customers are not affected. • Voltage control schemes can be technically challenging, especially in rural distribution networks. These networks are generally considered to be less robust and can involve a complex voltage control scheme. Therefore this can turn out to be a significant barrier to rural embedded generation connections if not appropriately managed.

  7. Communication Methods for Intertripping • For some industrial-scale solar farms the DNSPs may require the installation has a dedicated intertrip signal from the embedded generator to their control centre. Occasionally the DNSP may require a dedicated fibre optic cable for instant communication. • If there is a requirement for intertripping communication for your project it is best to determine the method as early as possible. It can cost a great deal and can often be overlooked and create an unexpected expense for your project.

  8. Voltage Fluctuation • There is no simple correction for voltage fluctuation at the end of long regional powerlines. • Normally this will require modeling to ensure the generator can sustain its output as the network voltage fluctuates. Voltage fluctuations also often occur in the event of the generating facility tripping off supply, or if the generator’s output fluctuates sharply.

  9. At BCJ Controls we support electrical installers by helping them connect to the grid. We provide protection solutions for diesel, generators, commercial solar, utility scale renewable energy generation projects. We are experts in designing and manufacturing anti-islanding and Zero-Export equipment, including testing and commissioning of grid connected projects.

  10. Our experience in solar protection and grid connection projects means we can design customized solutions for challenging projects. We build the grid connection boards for often difficult installations involving multiple buildings, existing systems, multiple brands of inverters, PLC ramping control, ethernet and wifi.