1 / 8

Design of Evacuation System for High-Rise Building Danqing Yu

Design of Evacuation System for High-Rise Building Danqing Yu. Overview. 30-years policy of US codes against use of elevators in fires ~ Attitudinal impediment Focus of current design: number, width and position of stairs ~ Is it adequate ?

avalon
Download Presentation

Design of Evacuation System for High-Rise Building Danqing Yu

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of Evacuation System for High-Rise Building Danqing Yu

  2. Overview • 30-years policy of US codes against use of elevators in fires ~ Attitudinal impediment • Focus of current design: number, width and position of stairs ~ Is it adequate? • Current use of elevator – Provide emergency use for firefighters and the disabilities • Move large number of people from significant height ~ Call for safe and reliable elevator egress system • Future trend ~ design elevators with emergency mode ( withstand heat, smoke, water, power-cut)

  3. Evacuation Plan for High-Rise Building • Normal high-rise building • Evacuation sequence: emergency floor – upper floors – lower floors • Whether or not the elevators attend to disabled population first before they serve others • Trained personnel to lead evacuation and good interface design ( switching driving mode for different emergencies) • Mega high-rise building • Elevators and refuge place are zoned vertically by sections • Occupants are regularly trained for evacuation • Express emergency shaft transit from refuge place to ground lobby in a non-stop fashion

  4. Buildings Types Need Emergency Elevators • Residential Building • Buildings with more than 100 persons per floor and with more than 50 floors • Buildings with more than 200 persons per floor and with more than 20 floors • Office Building • Buildings with more than 50 floors and more than 50 persons per floor • For 15-20 floor building, population per floor exceeds 100

  5. Parameters for Evacuation System • Parameters of Building Evacuation Traffic Flow • Building population • No. of floors: f (1 f  F) • Average passenger walking speed: (0.5~0.75m/s) • Passenger density during emergency (1 person/0.46m2) • Configuration for Evacuation System • Proportion of population evacuated by stairs and elevators • Width of evacuation doors (> 0.8m) • Width and travel distance of stairs • Positions of stairs and lobbies • Size of the lobbies • Emergency elevator configuration (number, safety mode, driving speed, group control logic )

  6. Objective: Minimize total passenger evacuation time ~ Time between the beginning of evacuation and the time when the last passenger departs. Min Te, with Te= max (Tstairegress , Televatoregress) • Evacuation by stairs • Evacuation by elevators ~ Assume elevators are loaded by passengers from one floor Corresponding to different highest reversal floor Statistical Method

  7. Constraints associated with building traffic flow • Space limitation • Budget consideration • Service quality requirement Normal mode Emergency mode • Objective for configuring traffic system • Minimize the weighted sum of average waiting time (or total service time) during normal mode and the evacuation time during emergency mode

  8. Safety regulation • Emergency mode for elevators Water tolerance parts, Emergency power if main power fails Enclosed lobby on each floor of the building, elevator should be installed in smoke-proof shaft 1 hour fire resistance and pressurized against smoke infiltration. Real time monitoring of elevator system status and any conditions that may threaten its safe operation. • Max No. of elevators and stairs • The number of floors in each elevator zone  15 ~ 16 floors • Layout of elevators and stairs Typical building: 3000 m2 of floor space, 500 m2 core area (including elevator, 2 stairs: 1.2 m each) Stairs are located diagonally across the core area from each other.