Polarization decay in a fill for 100 and 250 GeV beams

Polarization decay in a fill for 100 and 250 GeV beams. CNI group. Run 11 250GeV. Blue-1 Upstream slope = -0.39 ± 0.07 %/ hour. Blue -2 Downstream slope = - 0.19 ± 0.07 %/ hour. Run 11 250GeV. Yellow- 2 Upstream slope = - 0.79 ± 0.07 %/ hour. Yellow-2 Downstream

avalon
Download Presentation

Polarization decay in a fill for 100 and 250 GeV beams

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Polarization decay in a fill for 100 and 250 GeVbeams CNI group

  2. Run 11 250GeV Blue-1 Upstream slope = -0.39 ± 0.07 %/hour Blue-2 Downstream slope = -0.19 ± 0.07 %/hour

  3. Run 11 250GeV Yellow-2Upstream slope = -0.79 ± 0.07 %/hour Yellow-2 Downstream slope = -0.86 ± 0.11 %/hour

  4. Run 11 250 GeVH-Jet Polarization by 2-hour time period in fill Red: yellow beam blue: blue beam

  5. Run9 1/Tdecay (h) From Run9 pC AN On the average 1/T~0.01 h-1 Means ~1% per hour Up to 1/T=0.02-0.03 h-1 or so, which means ~2-3% per hour

  6. Run8 1/Tdecay (h) From Run8 pC AN On the average 1/T~0.01 h-1 Means ~1% per hour in yellow Somewhat on the average better in blue (0.3% per hour) but varies more

  7. Run6: From Carlos’s CNI presentation o n Sep 27, 2007 dP/dt (%/h) Absolute polarization decay ~0.3-0.4% per hour Which translates to relative decay ~0.6-0.8% per hour