370 likes | 832 Views
Fabrication of Biosensors and Lab Testings III. Jack Nguyen Xiaodong Ma 05/14/2008. For today. Theory/Background, Testings – Jack Result, other two experiments– Xiaodong. OBJECTIVES OF PROJECT: Fabrication of FP Biosensors
E N D
Fabrication of Biosensors and Lab Testings III Jack Nguyen Xiaodong Ma 05/14/2008
For today • Theory/Background, Testings – Jack • Result, other two experiments– Xiaodong
OBJECTIVES OF PROJECT: Fabrication of FP Biosensors Repeated Analyze antigen/antibody (Influenza A/anti-Influenza A ) interactions Test different Techniques / Antigens MATERIALS: Fiber Optic Strands, CTS Machine, Matlab, PMMA/Acetone solution, Protein G’(10µg/ml), 2% BSA in PBS, Influenza A(20µg/ml), Anti-Influenza A Ig G(20µg/ml), Distilled water, 3-aminopropyltriethoxysilane, Acetone, Ethanol, Microscope, Light, Controllable stage
Budget Budget: $0, all materials provided by UML
Schematic graph of biosensor Influenza A Primary Antibody Pro.G poly(methyl 2-methylpropenoate) Optical Fiber
Procedure SENSOR PMMA PBS BSA WATER Pro.G WATER PBS IgG Inf.A PBS WATER WATER PBS DATA
Time Duration • Fabrication FP sensor : 30 Minutes • PMMA: 2 Hours • Pro.G: 1.5 Hours • BSA: 1.5 Hours • IgG: 1.5 Hours • Influ. A: 1.5 Hours • Total PBS: 5 Hours • Total Hours for a typical lab test: 13-16 Hr • When a lab test fails, we start all over with the FP sensor fabrication
Experimental setup Chiller Matlab Program CTS Fiber Biomaterials
Experimental setup Polymer tube Fiber Glass tube
Experimental setup Stage Detector Stage power Connector to CTS Sensor
Experimental setup Light Source VIS Spectrometer Detector SiO2/Si
Experimental steps • Wash out the dust of SiO2/Si substrates several times by DI water. • Wash the SiO2/Si substrates by sonication in acetone, ethanol and DI water for 15 min, respetively. • Put the cleaned and dry SiO2/Si substrates in 2% solution of 3-aminopropyltriethoxysilane in acetone (3-aminopropyltriethoxysilane : acetone =1 : 49 by volume ) at room temperature for 30 seconds. • Measure the substrates’ spectra by VIS spectrometer after SiO2/Si substrates dried. • Drop Pr.G’ on SiO2/Si substrates for 1.5 h, wash by DI water 3 times, air-dry and detect its spectra. (For comparison experiment, drop BSA on the substrates first and then wash and detect spectra.) • Drop anti-Inf.AIgG on the surface for 1.5 h, wash by DI water 3 times, air-dry and test its spectra. (For comparison experiment, drop Pr.G’ on the surface with BSA and wash, dry detect spectra.) • Drop Inf.A on the surface for 1.5, wash by DI water 3 times, air-dry and then measure its spectra. • Analyze the spectra of two groups experiment.