60 likes | 162 Views
Application of HICUM and TRADICA at JazzSemi. 2002 BCTM HICUM User’s Meeting. History. The HICUM model has been available at Rockwell Conexant Jazz since 1996 In house implementation in Spectre-RF, Eldo, and MDS until 1999 Public domain release in 1999
E N D
Application of HICUM and TRADICA at JazzSemi 2002 BCTM HICUM User’s Meeting
History • The HICUM model has been available at Rockwell Conexant Jazz since 1996 • In house implementation in Spectre-RF, Eldo, and MDS until 1999 • Public domain release in 1999 • Build-in model maintained (w. r. t. simulator updates) by Cadence. • Parameter extraction infrastructure has been implemented in Matlab using Spectre-RF and TRADICA. • TRADICA has been used as HICUM library generation and parameter predications.
Present Status • JazzSemi has become a foundry since March 2002. • JazzSemi releases SGPM and HICUM using TRADICA and existing infrastructure. • JazzSemi has BiCMOS model library for a variety of processes: • BC30 (30 GHz Si BiCMOS on 0.35mm CMOS platform) • SiGe60 (70 GHz SiGe BiCMOS on 0.35mm CMOS platform) • SiGe120 (150 GHz SiGe BiCMOS on 0.18mm CMOS platform)
SiGe120 Bipolar Library ... 1E1B1C Emitter length el=0.76um ... ... 1E2B1C ... Emitter Width ew=0.2um digital 2.0V BVceo . . . 2E3B2C Emitter Width ew=0.6um NPN Library LV 3.8V BVceo ... 3E4B2C Emitter length el=10.16 ... ... ... Emitter Width ew=0.9um HV 6V BVceo 4E5B2C ... 1E2B2C Fully physically scaled, discrete npn model set
SGPM and HICUM Model NPN Model HICUM SGP • Improved fT fit at high current • Improved Early effect modelling • BC avalanche • Improved temp. model • Self heating(off by default) • Short simulation time • Numerical stable
Examples of Verification Plots • HICUM is the primary choice when Ic is high and VBC is small. • Self-heating usually is off and can be turned on per request.