1 / 21

16.422 Human Supervisory Contorl

16.422 Human Supervisory Contorl. Nuclear and Process Control Plants. Massachusetts Institute of Technology. Process Control Plants. 16.422. • Continuous or batch processing • Example:Electricity generation (nuclear power Plants),refineries, stell production, paper mills,

berke
Download Presentation

16.422 Human Supervisory Contorl

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 16.422 Human Supervisory Contorl Nuclear and Process Control Plants Massachusetts Institute of Technology

  2. Process Control Plants 16.422 • Continuous or batch processing • Example:Electricity generation (nuclear power Plants),refineries, stell production, paper mills, Pasteurization of milk • Characterzied by: –Large scale, both physically and conceptually –Complex –High risk –High automation • Remote vs. direct manipulation of plant equipment

  3. Three Mile Island 16.422 • March 28th 1979 • Main feedwater pump failure, caused reactor to shut down • Relief valve opened to reduce pressure but became stuck in the open position – No indication to controllers – Valve failure led to a loss of reactant • No instrument showed the coolant level in the reactor • Operators thought relief valve closed & water level too high –High stress –Overrode emergency relief pump

  4. Three Mile Island 16.422 • Automation worked correctly • Confirmation bias: people seek out information to confirm a prior belief and discount information that does not support this belief – At TMI, operators selectively filtered out data from other gauges to support their hypothesis that coolant level was too high

  5. Process Control Human Factors Challenges 16.422 • Control room design • Increasing automation requires cognitive support as opposed to manual control support • Human-machine interface design • Team decision making • Standardized procedures vs. innovatuon • Trust & confidence

  6. Supercvisory Process Control Tasks 16.422 • Monitor process • Detect disturbances, faults, & abnormalities • Counter disturbances, faults, & abnormalities • Operating procedures must be followed • Communications –A log must be kept –Other team members ( shift changes ) • Emergency procedures •Training and retraining

  7. Cognitive Demands When Monitoring Process Control Plants 16.422 • Vigilance – Continuous vs. time shire – Active vs. passive monitoring • Memory • Selective attention • Visual attention/perception • System complexity • System reliability – Critical vs. non-critical components

  8. Cognitive Demands, cont. 16.422 • Display and control design – Lack of referent values – Lack of emergent featurs – Lack of intergrated information • Alarm system design – Nuisance alarms – Cycling around limits • Desensitizaation • Automation design – Lack of appropriate feedback – Direct vs. indirect cues

  9. Coping Strategies 16.422 • Increase desired information salience and reduce background noise – Clearing and disabling alarms – Cross checking with other reactor • Create new information – Operators manipulated set points for earlier alarms • Offload cognitive processing onto external aids – Leaving door open &sticky notes • Deviations from “approved” procedures

  10. Advanced Displays in process Control 16.422 • Classical display ( bar graphs, meters, annunciators ) are being replaced with computerized displays – Keyhole effert – Temporal considerations – Integration of information • Flexible & adaptable displays – Local vs. global problems • Configural & Ecological displays

  11. Configural Displays 16.422 • Separable vs. integral vs. configural • Gestalt principles in design • Emergent features

  12. A Process Control Design Case Study 16.422 • Model-Based Predictive Control (MPC) of a refinery plant • Multi-input & multi-output autimatic controlls – Optimize the process based on maximizing production and minimizing utility cost. – Higher levels of automation – human less in the loop • Three variable types – CVs – Controlled Variables – process variables to be kept at setpoints or within constraints (20-30 variables). – MVs – Manipulated Variables – Variables (typically valves) that are adjusted to achieve CVs while optimizing (6-8variables). – DVs – Disturbance variables – Variables that can measured but not controlled, e.g., ambient air temp. (2-3 variables) • Humans have difficylty monitoring, diagnosing, controlling these advanced systems

  13. REGEN BED TEMP Detail Display 16.422 CV DETAIL RX / REGEN CTL ON OFF WARM OPTIMIZING TAG 25ATCV01 DESC REGEN BED TEMP SOURCE 25ATCV01.PV LINEAR OBJ COEF -1.00 PV VALUE 579.3 PRED VAL 579.36 FUTURE 579.38 SS VALUE 581.36 QUAD OBJ COEF DESIRED CV VAL SCALING FACTOR 0.00 STATUS GOOD 0.00 0.329 SP.LIM TRACKS PV UPDATE FREQUENCY CRITICAL CV CONTROL THIS CV YES NO = < CV LO ERROR WEIGHT CV HI ERROR WEIGHT 1.00 YES NO 1.00 SETPOINT NO YES PERFORMANCE RATIO CLS LOOP RESP INT FF TO FB PERF RATIO 1.00 LO LIMIT ACTIVE 400.00 # OF BAD READS ALLOWED 54.800 5 0.50 400.00 LO LIMIT RAMP RATE HI LIMIT RAMP RATE UNBIASED MODEL PV 10.000 HI LIMIT ACTIVE 600.00 0.00 10.000 SETPOINT GAP NUMBER OF BLOCKS 600.00 10.0 379.35 APPLCN MENU PROCESS DISPLY CV DISPLY MV DISPLY DV DISPLY STATUS MESG MV TUNING CV TUNING GAIN/ DELAY TREND DISPLY

  14. Gain/Delay Matrix _ The Goal State 16.422 ONLINE GAIN AND DELAY CHANGE RX / REGEN CTL ON OFF OPTIMIZING WARM MV01 MV02 MV03 MV04 MV05 MV06 MV07 MV08 MV09 MV10 DV01 CV DESCRIPTION REACTOR BED TEMP -1.0 2.0 -3.5 4.2 6.1 -0.5 0.25 1 2 3 4.0 5.9 REGEN BED TEMP -0.5 REGEN EXCESS O2 0.3 -1.0 2.0 -3.5 4.2 6.1 0.25 RX/REGEN DELTA P 4 .12 -1.0 2.0 -3.5 4.2 6.1 -0.5 0.25 -3.0 4.2 6.1 -0.7 0.70 REGEN CAT SLV DP 10.0 1.0 -2.5 5 6 SPENT CAT SLV DP -0.4 7.2 9.0 -8.0 -2.0 6.9 STRIPPER LEVEL 7 12.0 8 3.0 9.0 1.5 3.6 BLOWER AMP's -.60 5.2 -2.5 -3.5 WET GAS RPM's 9 1.2 10 FEED HDR-PRESS -5.5 .02 6.2 -8.3 2.1 3.0 FRAC BTMS TEMP 11 2.2 -7.3 4.5 FRAC DELTA PRESS 12 .04 BLOWER VLV OP 5.1 4.4 2.6 -9.0 -.06 5.5 13 6.3 -.25 3.2 4.0 6.2 14 WET GAS VLV OP -0.4 4.3 7.0 -8.2 15 RX PRED OCTAN E Gain Multiplier 1.000 Deadtime Bias 0.000 3.750 Deadtime 0.000 Max Deadtime 2.00 Gain PROCESS DISPLY MV DISPLY TREND DISPLY APPLCN MENU CV DISPLY DV DISPLY STATUS MESG MV TUNING CV TUNING GAIN/ DELAY

  15. The Display Redesign 16.422

  16. Supporting Monitoring 16.422 • Overview display – Alerts • Easy recognition of priblems – Summary – Direct manipulation • Representation Aiding – Trend information depicted graphically •variable state as well as optimization history – Color important

  17. Supporting Diagnosing 16.422

  18. Representation Aiding in Diagnosis 16.422 d a b c e f g h i j a. b. c. d. e. f. g. h. i. j. Normal state, both operator and hard engineering limits shown Normal state, operator limits = engineering limits Normal, no engineering hard limits defined Current state within 1% of operator limits Current state exceeded operator limits Normal state, variable constrained to setpoint. Value “wound-up”, valve fully closed or open Negative linear coefficient (maximize value) Poditive linear coefficient (minimize value) Non-zero quadratic coefficient (resting value)

  19. Supporting Interaction 16.422 • Performance over time • Important to provide “logging” ability • What-if

  20. Decision Aid Design 16.422 • An assistant versus a coach – what-if’s (a form of preview ) – Narrowing a solution space – Recommendations – Critiquing • Problems – Clumsy automation? • Will they work in all situations – Codifying rules and updating them • Plant upgrades & system evolution • Especially tricky in intentional domains – Automation bias • Interactivity in decision support

  21. References 16.422 N. Moray, “Human Factors in Process Control,” in Handbook of Human Factors and Ergonomics, edited by G. Salvendy, pp.1944 – 1971, 1997. C. Burns, “Putting It All together: Improving Display Integration in Ecological Displays,” Human Factors, vol. 42, pp. 226-241, 2000. R. Mumaw, E. M. Roth, K. Vicente, and C. Burns, " There is more to monitoring a nuclear power plant than meets the eye, " Human Factots, vol. 42, pp. 36-55, 2000. S. Guerlain, G Jamieson, P. Bullemer, and R. Blair, " The MPC Elucidator: A case study in the design of representational aids, " IEEE Journal of Systems, Man, and Cybernetics, vol. 32, pp. 25- 40, 2002.

More Related