GAS / FLAME DETECTION GAS / DUST MONITORING YOUR ENVIRONMENT,YOUR SAFETY, LET ’S MASTER THEM TOGETHER
MX48 = 4 or 8 independant channels MX 15= single channel MX52 = 2 to 16 independant mixtedchannels MX32 = 2 independant channels WINGAS = 4 independant channels redundant system MX62 = Up to 64 independant channels MX42A = 4 independant channels
small-sized wall-mounted box For low cost installations (boiler plants, battery charging rooms…) DIN rail mounting… MX 15:easy installation
Measurement and alarm unit:MX 15 • Synergy with new detectors OLC(T) 10 • Can be linked either with a single flammable detector (OLC10/OLCT10) • Or can be linked with two flammable detectors ( OLC10 TWIN) • Or can be linked with one up to five toxic transmitters OLCT10 ( CO, NO, NO2).
Example of wiring arrangement between MX15 and 3 -active- wire- detector: OLC10 or OLCT10.
between MX15 and two flammable detectors:OLC10 TWIN.
MX 15 : user-friendly front panel LCD display, pictograms, concentration, type of gas and unit indication (programmable). • - LED visual indications: • ON/OFF • AL1 and AL2 • Trouble
ALARMS : 2 independent programmable levels Increasing or decreasing alarm Automatic or manual, local or remote acknowledgement. RELAYS: 2 independent alarm relays 1 fault relay Fail safe (energized) or negative safety Free potentiel contacts (2A/250ACV). MX 15 :alarms and relays
MX15 : simple operation • Keypad for using (menus): • initialization (1rst installation) • programming (of channel) • test (relays inhibited during calibration) • code (authorized people) • buzzer (mode).
small-sized wall-mounted box protected front face IP66 housing. MX 32:easy installation
Per channel: 1 independent relay for each gas alarm (2) 1 common relay for troubles. MX 32: relays 1 1 D 2 2
maintenancemenus: initialization (1st installation) channel programming calibration (relays inhibited) Code (authorized people) buzzer ( local audible alarm). MX 32:keypad
Wall-mounting housing: easy to install 1 to 4 independent channels MX 42A
MX 42A:relays COMMON BLOCK channel 3 channel 4 channel2 Channel 1 D 3 1 2 1 2 1 2 1 2 - per channel: 1 independent relay per instantaneous gas alarm (2) - 1 common relay for the 3rd gas alarms (from each channel), or for all the gas alarms - 1 common fault alarm relay
MX 42A:analog outputs COMMON BLOCK 3 4 2 Channel 1 • recorder or PLC or • data logging. 4 - 20 mA - - - - + + + + Common ground an independent 4-20 mA output per channel.
MX 42A:maintenance switches : 6 7 8
Position 0 = OFF position 1 = ON 8 = on/off 7 = calibration (flashing yellow LED and alarm relay - inhibition) 7 + 6 = programming (flashing yellow LED and alarm relay - inhibition) . Maintenance switches 0 1 6 7 8
8 + 7 = : calibration « 0 and Span » setting with potentiometers Maintenance switches: calibration 7 8
8 : normal mode 7 + 6 = programming KEYBOARD Call on display (for 1 mn) Messages : - AL1 - AL2 - AL3 - Point - Time - + - states - values ...
WINGAS • WINGAS is a fixed controller : • with a wall mounting housing IP 54 • for COMMERCIAL and INDUSTRIAL markets.
WINGAS : 2 versions • WINGAS DIGITAL: with display • WINGAS : without display
WINGAS :multi-channel controller • 4 channels • 1 transmitter 4/20 mA2 or 3 wires per channel • specific case : up to a maximum of 5 transmitters CO 4/20 mA 2 wires • No explo bridge detector .
123456 6 fils Vers boîte relais WINGAS : configuration FRONT PANEL CASING Display Pcb MAIN Pcb
WINGAS : ALARMS • 2 GAS alarms per channel COMMON FAULT ALARM
WINGAS : on-board RELAYS • 2GAS alarm common relays • 1buzzer copy common relay • 1FAULT alarm common relay
WINGAS: FRONT PANEL Gas alarm lamps On/off lamp Fault lamp Acknowledgement button Display (digital version ) Maintenance button
WINGAS DIGITAL • Only in the case of a WINGAS DIGITALwe can connect a remote box fitted with 8 relays • Each gas alarm AL1 and AL2 of WINGAS DIGITAL will then drive 2 remote relays AL1 and AL2.
REMOTE BOX • The remote box is connected to the wingas digital with a 6 wire cable : max. length = 30m (0.9mm2). to wingas digital
WINGAS NETWORK Network: up to 32 WINGAS maximum
WINGAS NETWORK • The network WINGAS RS 485 is driven by a software: WINGASCOM • It allows to visualize and program the differentWINGAS connected to the network
Metal wall- mounting housing 4 to 8 independent channels. MX 48
BUS/MICRO/display card common block 2 cards (4 channels per card) MX 48 : presentation
MX 48: front panel • AL 1 and AL2 = instantaneous alarms • AL 3 = delayed or averaged alarm
MX 48 :relays - 2 common relays (Al3 and faults) - 2 relays (Al1/Al2) per channel channels 1 to 4 5 to 8
Analog outputs: 4 to 20 mA -an independent 4 /20 mA output per channel : to recorder, PLC ....
communications: RS 232 and RS 485 COMMUNICATION COM 52 < < < RS 232 < < < < < < > > > RS 485 SUPERVISION > > > >
with push-buttons : calibration programming MX 48 : maintenance
MX 52 - rack 3U/19 inc. - 2 to 16 channels ( features of MX 48 = MX 52 ).
a safety system ... MX 62