Ultrasound. presented by BAM. Equipment BAM. Power supply Waveform generator (any arbitrary of pulse forms) Power Amplifier Oscilloscope Computer. Measurements Overview. Measurement - Historic Masonry. „Kirche am Anger“ Potsdam-Babelsberg Brandenburg / Germany.
E N D
Ultrasound presented by BAM
Equipment BAM • Power supply • Waveform generator (any arbitrary of pulse forms) • Power Amplifier • Oscilloscope • Computer
Measurement - Historic Masonry „Kirche am Anger“ Potsdam-Babelsberg Brandenburg / Germany Year of construction: 1850-52 By: Ch. H. Ziller
Transducers A1220 array with transversal transducers (no coupling agent required) 12 Transmitters Polarisation of waves 12 Receivers
Result measurement – Historic Masonry Position [cm] 4 8 12 16 20 40 60 80 100 0 Represents the depth of 118 mm 100 200 Depth [mm] 300 400 500 600 700
Specimen Brickwork 25 cm Specimen Homogeneous brickwork Used for Selection of optimal transducers
Transducers A1220 A1220 array with transversal transducers (no coupling agent required) 12 Transmitter Polarisation of waves 12 Receiver
Results: Only the first row of bricks was detectable with the A1220 The system seems not to be suitable for masonry investigation
Specimen Brickwork 25 cm Specimen Homogeneous brickwork Used for Selection of optimal transducers
Transducers planar and exponential Broad band (planar) transducer (coupling agent: glycerine) G 0,1 R and G 0,2 R nominal Frequency: 80 to 250 kHz Narrow band transducer (point contact, exponential horn) nominal Frequency: 50 and 100 kHz
Results specimen 25cm (G 0,2 GC) Intensity a.u. t Time [µs] Intensity a.u. t Time [µs]
Specimen Brickwork 49 cm Measuring line 0-70cm Specimen Brickwork with voids used for tomography Location of voids
Transducersplanar and exponential Broad band (planar) transducer (coupling agent: glycerine) G 0,1 R and G 0,2 R nominal Frequency: 80 to 250 kHz Narrow band transducer (point contact, exponential horn) nominal Frequency: 50 and 100 kHz
Aperture Angle Intensity of transmitted signal related to the aperture angle (Broad band transducer)
Measurements tomography 1 Intensity a.u. t Time [µs] DATA FOR TOMOGRAPHY Measurement – time of flight (Broad band transducer G0,2R) Signal No 3 and 32 Intensity a.u. t Time [µs]
Measurements tomography 2 Intensity a.u. t Time [µs] DATA FOR TOMOGRAPHY Measurement – time of flight (Narrow band transducer exponential horn) Signal No 1 and 21 Intensity a.u. t(?) Time [µs]