180 likes | 347 Views
Homogeneity of the long term ozonesonde observation record in the troposphere and the stratosphere for Uccle. Andy Delcloo and Hugo De Backer. Ozonesonde. Ozone profiles Balloon soundings Brewer-Mast sondes 1969-1997 Z-ECC-sondes since April 1997 3 x week: Mo-We-Fri. Trends. Trends.
E N D
Homogeneity of the long term ozonesonde observation record in the troposphere and the stratosphere for Uccle Andy Delcloo and Hugo De Backer Sparc/IOC/WMO-IGACO workshop on Past Changes in the Vertical Distribution of Ozone, Geneva, Januari 25-27 2011
Ozonesonde Ozone profiles Balloon soundings Brewer-Mast sondes 1969-1997 Z-ECC-sondes since April 1997 3 x week: Mo-We-Fri
Pump efficiency Box temperature (taking into account) Changes from BM ECC sondes Changes in pre-flight conditions Altitude error SO2 interference Background current… Standard correction <-> correction for temperature and pressure. ftp.kmi.be/dist/meteo/hugo/publ/1999/o3prof.pdf Changes in the procedure to get to the best possible time series
Standard <-> adapted correction Standard temperature Fixed pump correction Linear correction to correct for the total measured ozone column compared with the integrated total ozone column • Boxtemperature is measured if available • Pump correction is replaced by pressure dependent correction to correct for total ozone by using measured total ozone column data.
Use of SAGE-II data Is a satellite which uses the principle of onion peeling Use of auto-calibration ! Important if you want to look for discontinuities in time series Time series used from 1985 – 1999 Change from BM ECC 1997 Which procedure can we apply to check for inconsistencies?
SAGE-II 26 _ 30 KM 26 _ 30 KM Using additional corrections Using WMO standard corrections
What about the quality of tropospheric ozone ? Use of a chemical transport model: CHIMERE ECMWF (50 km) ERA-INTERIM
Cross-section O3-profile Uccle 5 km GL
Capability of a CTM to catch vertical variability (1997 experiment)
Integrated ozone profiles between 736 hPa and 541 hPa Ozone anmaly (%)
Procedure • Run 20 years of CTM output on a regional scale to identify the evolution of the day-to-day variability for free tropospheric ozone. • Different scenarios for emissions • Is the model able to explain differences in lower free tropospheric ozone concentrations between the three European ozone sounding stations • Emissions • Dynamical effects (meteorology)
Conclusions • Anomalies for the higher stratospheric ozone concentrations have succesfully been homogenised through the apllication of supplementary correction factors taking into account • Boxtemperature • Pressure dependent correction • Lower free tropospheric ozone concentrations will be verified with CTM output
Ozone, UV and aerosol group UV Modelling Radiative transfer for UV-index forecast Utsteinen – Antarctica – Princes Elisabeth station