An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chem. 230 – 9/25 Lecture

  2. Announcements I • Quiz 1 Results • Solutions have been posted • See class distribution • Grade cut-offs have not been set, will depend somewhat on class scores • Based on Quiz 1, I might expect cut-offs a couple of % below 90/80/70%

  3. Announcements II • HW 2 long problems due next week • One group still needs to choose a topic for student presentations • What we are covering today? • More Definitions: Last question • Band broadening theory (Section 3.2) • Intermolecular Forces (Section 4.1) • Optimization (if time)

  4. Chromatographic TheoryQuestions on Definitions • Given the two chromatograms to the right: • Which column shows a larger N value? • Which shows better resolution (1st 2 peaks top chromatogram)? • Which shows better selectivity (larger α; 1st 2 peaks on top)? • Should be able to calculate k, N, RS, and α Unretained pk

  5. Chromatographic TheoryRate Theory • We have covered parameters measuring column efficiency, but not covered yet what factors influence efficiency • In order to improve column efficiency, we must understand what causes band broadening (or dispersion) • van Deemter Equation (simpler form) where H = Plate Height u = linear velocity and A, B, and C are “constants”

  6. Chromatographic TheoryRate Theory Most efficient velocity H C term B term A term U

  7. Chromatographic TheoryRate Theory Inside of column (one quarter shown) • How is u determined? • u = L/tM • u = F/A* (A* = effective cross-sectional area) • “Constant” Terms • A term: This is due to eddy diffusion • Eddy diffusion results from multiple paths Shaded area = cross-sectional area = area*porosity X X X dispersion

  8. Chromatographic TheoryRate Theory • A Term • Independent of u • Smaller A term for: a) small particles, b) spherical particles, or c) no particles (near zero) • Small particles (trend in HPLC) results in greater pressure drop and lower flow rates

  9. Chromatographic TheoryRate Theory • B Term – Molecular Diffusion • Molecular diffusion is caused by random motions of molecules • Larger for smaller molecules • Much larger for gases • Dispersion increases with time spent in mobile phase • Slower flow means more time in mobile phase X X X Band broadening

  10. Chromatographic TheoryRate Theory • C term – Mass transfer to and within the stationary phase • Analyte molecules in stationary phase are not moving and get left behind • The greater u, the more dispersion occurs • Less dispersion for smaller particles and thinner films of stationary phase • Less dispersion for solute capable of faster diffusion (smaller molecules) X X dispersion Column particle

  11. Chromatographic TheoryRate Theory • More generalities • Often run at u values greater than minimum H (saves on time; reduces σ which can increase sensitivity depending on detector) • For open tubular GC, A term is minimal, C term minimized by using smaller column diameters and stationary phase films • For packed columns, A and C terms are minimized by using small particle sizes Low flow conditions Higher flow conditions

  12. Chromatographic TheoryRate Theory Some Questions: • What are advantages and disadvantages of running chromatographs at high flow rates? • Why is GC usually operated closer to the minimum H value than HPLC? • Which term is nearly negligible in open tubular GC? • How can H be decreased in HPLC? In open tubular GC?

  13. Chromatographic TheoryEffects of Intermolecular Forces • Phases in which intermolecular forces are important: solid surfaces, liquids, liquid-like layers, supercritical fluids (weaker) • In ideal gases, there are no intermolecular forces (mostly valid in GC) • Intermolecular forces affect: • Adsorption (partitioning to surface) • Phase partitioning • Non-Gausian Peak Shapes

  14. Chromatographic TheoryIntermolecular Forces – Asymmetric Peaks • More than one possible cause (e.g. extra-column dispersion) • One common cause is sample or analyte overloading of column • Analyte loading shown → • More common with solid stationary phase • More common with open tubular GC; less common with HPLC 5% by mass ea. 20% by mass ea.

  15. Chromatographic TheoryIntermolecular Forces – Asymmetric Peaks Low Concentrations • Most common for solid stationary phase and GC because • Less stationary phase (vs. liquid) • GC behavior somewhat like distillations • At low concentrations, column “sites” mostly not occupied by analyte • As conc. increase, % sites occupied by analyte increases, causing change in analyte – stationary phase interaction Active sites analyte X High Concentrations New analyte X X X X X

  16. Chromatographic TheoryIntermolecular Forces – Asymmetric Peaks • As concentration increase, interactions go from analyte – active site to analyte – analyte • If interaction is Langmuir type (weak analyte – analyte vs. strong analyte – active site), tailing occurs (blocking of active sites causes additional analyte to elute early) • If interaction is anti-Langmuir type (stronger analyte – analyte interactions), fronting occurs (additional analyte sticks longer) Tailing peak (up fast, down slow) Fronting peak (up slow, down fast)

  17. Chromatographic TheoryIntermolecular Forces – Asymmetric Peaks • If tailing is caused by saturation of stationary phase, changing amount of analyte injected will change amount of tailing and retention times

  18. Chromatographic TheoryIntermolecular Forces – Odd Peak Shapes Other Reasons for Odd Peak Shapes • Large volume injections • Example: 1.0 mL/min. + 0.1 mL injection Injection plug time = 0.1 min = 6 s (so no peaks narrower than 6 s unless on-column trapping is used) • Injections at high temp./in strong solvents Will not partition to stationary phase until mobile phase mixes in In strong solvent X X X Analytes stick on column until stronger mobile phase arives X X In weak solvent X

  19. Chromatographic TheoryIntermolecular Forces – Odd Peak Shapes • Analyte exists in multiple forms • Example: maltotetraose (glu[1→4]glu[1→4]glu) • Has 3 forms (α, β, or aldehyde on right glu) • α and β forms migrate at different rates • At low T, interconversion is slow relative to tR. At high T, interconversion is faster • Extra-column broadening/turbulent flow • Multiple types of stationary phase Low T High T X X Polar groups OH OH Non-polar groups

  20. Chromatographic TheoryIntermolecular Forces – Types of Interactions Interactions by decreasing strength Ion – Ion Interactions Strong attractive force between oppositely charged ions Of importance for ion exchange chromatography (ionic solute and stationary phase) Also important in ion-pairing used in reversed-phase HPLC Very strong forces (cause extremely large K values in absence of competitors) From a practical standpoint, can not remove solute ions from stationary phase except by ion replacement (ion-exchange) Ion – Dipole Interactions Attractive force between ion and partial charge of dipole d- d+ M+ :N=C-CH3

  21. Chromatographic TheoryIntermolecular Forces – Types of Interactions Interactions by decreasing strength – cont. Ion – Dipole Interactions – cont. Determines strength of ionic solute – solvent interactions, ionic solute – polar stationary phase interactions, and polar solute – ionic stationary phase interactions Important for some specific columns (e.g. ligand exchange for sugars or Ag+ for alkenes) Metal – Ligand Interactions ion – ion or ion – dipole interaction, but also involve d orbitals

  22. Chromatographic TheoryIntermolecular Forces – Types of Interactions Interactions by decreasing strength – continued (non-ionic interactions = van der Waal interactions) Van der Waals Forces dipole – dipole interactions (requires two molecules with dipole moments) important for solute – solvent (especially reversed phase HPLC) and solute – stationary phase (especially normal phase HPLC) Hydrogen bonding is a particularly strong dipole-dipole type of bonding dipole – induced dipole interactions induced dipoles occur in molecules with no net dipole moment larger, more electron rich molecules can get induced dipoles more readily induced dipole – induced dipole interactions (London Forces) occur in the complete absence of dipole moments also occur in all molecules, but of less importance for polar molecules

  23. Chromatographic TheoryIntermolecular Forces – Types of Interactions Modeling interactions Somewhat of a one-dimensional model can be made by assigning a single value related to polarity for analytes, stationary phases, and mobile phases (See section 4.3) These models neglect some interactions however (e.g. effects of whether an analyte can hydrogen bond with a solvent)

  24. Chromatographic TheoryIntermolecular Forces – Some Questions Describe the dominant forces involving the molecules to the right in interacting with non-polar molecules? in interacting with polar molecules How does going from DB-1 (100% methyl stationary phase) to DB-17 (50% methyl – 50% phenyl) in GC affect elution of fatty acid methyl esters? (e.g. C16 vs. C18 vs. C18:1)

  25. Chromatographic TheoryIntermolecular Forces – Some Questions Silica has many SiOH groups on the surface (pKa ~2). What interactions will occur with the analyte phenol, C6H5OH, if the eluent is a mixture of hexane and 2-propanol? Sugars are often separated on amino columns. A sugar that has a carboxylic acid group in place of an OH group will have extremely large retention times (at least at neutral pH values). What does this say about the state of the amino groups?

  26. Chromatographic TheoryIntermolecular Forces – Some Questions In reversed phase HPLC with a C18 column, benzene and methoxybenzene (anisole) have very similar retention times. What are the differences in the interactions between the two solutes and mobile phases and stationary phases? A heavily used non-polar GC column is used to separate non-polar to polar columns. Polar compounds are observed to tail. A new column replaces the old column, tailing stops, and the polar compounds elute sooner. Explain the observations.

  27. Chromatographic TheoryOptimization - Overview How does “method development” work? Goal of method development is to select and improve a chromatographic method to meet the purposes of the application Specific samples and analytes will dictate many of the requirements (e.g. how many analytes are being analyzed for and in what concentration?, what other compounds will be present?) Coarse method selection (e.g. GC vs HPLC and selection of column type and detectors) is often based on past work or can be based on initial assessment showing problems (e.g. 20 compounds all with k between 0.2 and 2.0 with no easy way to increase k) Optimization then involves making equipment work as well as possible (or limiting equipment changes)

  28. Chromatographic TheoryOptimization – Some trade offs Flow rate at minimum H vs. higher flow rates (covered with van Deemter Equation) – low flow rate not always desired because of time required and sometimes smaller S/N Maximum flow rate often based on column/instrument damage – this can set flow rate Trade-offs in reducing H In packed columns, going to small particle sizes results in greater back-pressure (harder to keep high flow) In GC, small column and film diameters means less capacity and can require longer analysis times Trade-offs in lengthening column (N = L/H) Longer times due to more column (often not proportional since backpressure at same flow rate will be higher)

  29. Chromatographic TheoryOptimization – Improved Resolution Through Increased Column Length Example: Compounds X and Y are separated on a 100 mm column. tM = 2 min, tX = 8 min, tY = 9 min, wX = 1 min, wY = 1.13 min, so RS = 0.94. Also, N = 1024 and H = 100 mm/1024 = 0.097 mm Let’s increase L to 200 mm. Now, all times are doubled: tM = 4 min, tX = 16 min, tY = 18 min. So DtR (or d) now = 2 min. Before considering widths, we must realize that N = L/H (where H is a constant for given packing material). N200 mm = 2*N100 mm. Now, N = 16(tR/w)2 so w = (16tR2/N)0.5 w200 mm/w100 mm = (tR200 mm/tR100 mm)*(N100 mm/N200 mm)0.5 w200 mm/w100 mm = (2)*(0.5)0.5 = 21-0.5 = (2)0.5 w200 mm = 1.41w100 mm RS = 2/1.5 = 1.33 Or RS 200/RS 100 = d/wave = (d200/d100)*(w100/w200)= (L200/L100)*(L100/L200)0.5 So RS is proportional to (L)0.5

  30. Chromatographic TheoryOptimization – Resolution Equation Increasing column length is usually the least desired way to improve resolution (because required time increases and signal to noise ratio decreases) Alternatively, k values can be increased (use lower T in GC or weaker solvents in HPLC); or αvalues can be increased (use different solvents in HPLC or column with better selectivity) but effect on RS is more complicated Note: above equation is best used when deciding how to improve RS, not for calculating RS from chromatograms