1 / 37

Flexure analysis with the X-shooter Physical Model

Flexure analysis with the X-shooter Physical Model. Paul Bristow (ESO Instrumentation) Thanks to: Andrea Modigliani, Joël Vernet & Florian Kerber, Sabine Moehler (ESO) Paolo Goldoni, Frédéric Royer & Régis Haigron (APC-SAp/CEA) Follow the Photons – Edinburgh – October 2011.

Download Presentation

Flexure analysis with the X-shooter Physical Model

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Flexure analysis with theX-shooter Physical Model Paul Bristow (ESO Instrumentation) Thanks to: Andrea Modigliani, Joël Vernet & Florian Kerber, Sabine Moehler (ESO) Paolo Goldoni, Frédéric Royer & Régis Haigron (APC-SAp/CEA) Follow the Photons – Edinburgh – October 2011

  2. Matrix Representation of Optics • ME is the matrix representation of the order m transformation performed by an Echelle grating with E at off-blaze angle . This operates on a 4D vector with components (wavelength, x, y, z).

  3. Applications • Wavelength calibration • Simulations • Early DRS development • Effects of modifications/upgrades • Instrument monitoring/QC • Advanced ETC?

  4. Some background • M. Rosa: Predictive calibration strategies: The FOS as a case study (1995) • P. Ballester, M. Rosa: Modeling echelle spectrographs (A&AS 126, 563, 1997) • P. Ballester, M. Rosa: Instrument Modelling in Observational Astronomy (ADASS XIII, 2004) • Bristow, Kerber, Rosa: four papers in HST Calibration Workshop, 2006 • UVES, SINFONI, FOS, STIS, CRIRES,X-shooter – Bristow et al (Experimental Astronomy 31, 131, 2011)

  5. X-Shooter (300nm-2.5m) • Commissioned 2009 • Vernet et al. 2011.A & A. in press • Model for UVB, VIS& NIR arms • Same model kernel • Independent configuration files • Cross dispersed, medium res’n, single slit • Single mode (no moving components) • Cassegrain & heavy => Flexure

  6. NIR Th-Ar HCL full slit

  7. Solar like stellar point source and sky

  8. X-shooter Flexure • Backbone flexure • Causes movement of target on spectrograph slits • Corrected with Automatic Flexure Compensation exposures • Spectrograph flexure • Flexing of spectrograph optical bench • Can also be measured in AFC exposures • First order translation automatically removed by pipeline UVB VIS NIR

  9. Lab Measurements • NIR arm • Multi-pinhole • Translational & higher order distortions

  10. AFC Exposures • Obtained with every science obs => large dataset ~300 exp from Jan – May 2011 • Single pinhole, Pen-ray lamp • Window: • 1000x1000 win (UVB 12/VIS 14 lines) • Entire array (NIR 160 lines) VIS UVB NIR

  11. Physical Model Optimisation FOR EVERY CALIBRATION EXPOSURE

  12. Choosing “open” parameters • All parameters open • Slow • Optimal result • Degeneracy • Physically motivated: • Related to flexure • Constrained by data • In these results: • Prism orientation; Grating Orientation; Grating constant; Camera focal length; Detector position and orientation

  13. NIR

  14. NIR

  15. NIR

  16. NIR (Product moment correlation)

  17. VIS

  18. VIS

  19. VIS

  20. UVB

  21. UVB

  22. UVB

  23. Summary • Simple physical modelling approach: • wavelength calibration for a number of instruments • Raw data simulation • Instrument monitoring • Application to X-shooter • Flexure monitoring • Allows identification of physical model parameters that correlate with instrument orientation

  24. Physical Model Optimisation • QC Data • 9 pinhole mask, arc lamp: • Th-Ar (UVB 250 lines x 9 & VIS 390 lines x 9) • pen-ray (NIR 140 lines x 9) • Daytime, Zenith (no flexure except hysteresis) • 1/week => small data set • Automatically processed by pipeline (ESO QC)

  25. Effective camera focal length (mm) Effective camera focal length (mm) UVB Camera temperature sensor reading (°C) VIS Camera temperature sensor reading (°C)

  26. Detector tilt (°) Detector tip (°) Effective camerafocal length (mm) Modified Julian Date (days)

  27. Explain “our Physical Models” • Compare to poly • Uses • Calibration • Simulation • Test DRS • Investigate modifications/upgrades • Monitor/understand instrument behaviour • History (Ballester & Rosa) • Introduce X-shooter • Overview • Flexure • Lab plots • AFC • Calibration exposures • Flexure Procedure • Optimisation for 1 exposure • Apply to all data • Choosing open parameters • Flexure Results • NIR • Residuals • Sin plot • Linear plots • Table – highlight interesting param combinations • UVB • Residuals • Linear plots • table • VIS • Residuals • Linear plots • table • Flexure conclusions • QC • Procedure • Results • Summary