190 likes | 320 Views
Measurement of the Coulomb quadrupole amplitude in the γ * p → Δ (1232) reaction in the low momentum transfer region. David Anez Saint Mary’s/Dalhousie University May 14, 2011. Introduction. Took measurements of the p ( e , e ′ p ) π 0 (pion electroproduction) reaction
E N D
Measurement of the Coulomb quadrupole amplitude in the γ*p→Δ(1232) reaction in the low momentum transfer region David Anez Saint Mary’s/Dalhousie University May 14, 2011
Introduction • Took measurements of the p(e,e′p)π0 (pion electroproduction) reaction • In the low Q2 region where the pion cloud is expected to dominate • With center-of-mass energies near the Δ resonance to look at the transition amplitudes between the nucleon and the delta • To better understand the Coulomb quadrupole transition amplitude behavior in this region and how it affects nucleon deformation David Anez – May 17th, 2011 2/15
World Data and Models David Anez – May 17th, 2011 3/15
World Data and Models David Anez – May 17th, 2011 4/15
World Data and Models David Anez – May 17th, 2011 5/56
World Data and Models • Q2 = 0.045 (GeV/c)2 • New lowest CMR value • θe = 12.5° David Anez – May 17th, 2011 5/15
World Data and Models • Q2 = 0.045 (GeV/c)2 • New lowest CMR value • θe = 12.5° • Q2 = 0.125 (GeV/c)2 • Validate previous measurements David Anez – May 17th, 2011 5/15
World Data and Models • Q2 = 0.045 (GeV/c)2 • New lowest CMR value • θe = 12.5° • Q2 = 0.125 (GeV/c)2 • Validate previous measurements • Q2 = 0.090 (GeV/c)2 • Bridge previous measurements David Anez – May 17th, 2011 5/15
The Experiment • Jefferson Lab, Hall A • February 27th – March 8th, 2011 • 1160 MeV e− beam • 4 & 15 cm LH2 target • Two high resolution spectrometers • HRSe and HRSh David Anez – May 17th, 2011 6/15
High Resolution Spectrometers • Vertical drift chambers • Particle tracking • Scintillators • Timing information • Triggering DAQ • Gas Cerenkov detectors • Particle identification • Lead glass showers • Particle identification David Anez – May 17th, 2011 7/15
Original Kinematic Settings David Anez – May 17th, 2011 8/15
Revised Kinematic Settings David Anez – May 17th, 2011 9/15
Actual Kinematic Settings David Anez – May 17th, 2011 10/15
Response Functions • Unpolarized cross section made up of four independent partial cross sections David Anez – May 17th, 2011 11/15
Response Functions David Anez – May 17th, 2011 12/15
Multipole Amplitudes David Anez – May 17th, 2011 13/15
Response Functions David Anez – May 17th, 2011 12/15
Response Functions • Truncated Multipole Expansion • Model Dependent Extraction • Fit theoretical model to existing data • Insert model values for background amplitudes David Anez – May 17th, 2011 14/15
Work Still to Do • Calibration Analysis: May 2011 • Data Analysis: January 2012 • Doctoral Thesis: December 2012 • Published Paper: October 2015 David Anez – May 17th, 2011 15/15