1.32k likes | 1.63k Views
Sales Training Seminar. Sales Training Seminar September 16-17, 2007. Introduction Mechanical draft systems and their applications Mechanical combustion air supply systems and their applications Boiler room simulator Mechanical dryer venting systems and their applications Product trailer
E N D
Sales Training Seminar September 16-17, 2007 • Introduction • Mechanical draft systems and their applications • Mechanical combustion air supply systems and their applications • Boiler room simulator • Mechanical dryer venting systems and their applications • Product trailer • Competition • Specification writing • FanCalc – CASV/CASI/MODS/MCAS
Sales Training Seminar September 16-17, 2007 • FanCalc – MDVS • Sales Training Part I – Engineering presentation • Test • Summary
EXHAUSTO Inc in North America • In Atlanta since 1990 • 25,000 sq.ft. office and warehouse • 86 authorized sales and service offices in USA and Canada.
EXHAUSTO in North America • 95% of products are in stock ready for immediate shipping. • Inventory level of $800-1,000,000 • Complete parts inventory
The First Fan - 1957 • The first chimney fan - a “first” worldwide and the foundation of EXHAUSTO’s existence
A 50-year Old Company • Founded in 1957 • 300,000+ sq.ft. of manufacturing and administration • High-tech ISO 9001 certified manufacturing facilities
Code Development and Publication • Involved in code and standard development (NFPA 54, NFPA 211 etc.) • Publish articles about venting and venting design. • Make presentations at regional ASHRAE chapters and other organizations every year.
Products – RSV Fan • 3/16 “ Cast aluminum housing • Hinged for easy service and cleaning • Direct drive • Class H insulated motor • Maintenance free • 482 ºF Continuous Duty • 575 ºF Intermittent Duty • UL 378 – Draft Equipment • Capacity: • 6,000 MBH on CAT I Appliances • 10,000 MBH on CAT IV Appliances
Products – RSV Fan • Stainless steel axial vane • Models range from 300-1750 CFM • Cooling vane mounted on the motor shaft for low static pressure systems • Quick response to pressure changes • Single phase 120 V AC RSV 009-016
Products – RSV Fan • Cast aluminum impeller wheel • 500-4000 CFM • Permanently attached balance weights • Cooling vane mounted on the back of the impeller • RSV200-315 are single phase 120 V AC • RSV400-450 are three phase 208 or 400 V AC RSV 200--450
Products – RSV Fan • The RSV fan can vent all appliance categories with or without barometric dampers • Up to 6,000 - 10,000 MBH • High temperature motor eliminates the need for secondary fan cooling • Simple design with few components reduces the risk of failure and simplifies service
RSIB – Power Venter • SS316 construction • Removable access door • Direct drive • Class A insulated motor - eliminates the need for secondary fan cooling • Maintenance free • Up to 575 ºF Duty • The RSIB fan can vent category I, II, III & IV appliances • Simple design with few components reduces the risk of failure and simplifies service • RSIB is of Type B, Spark Resistant Construction • UL 378 – Draft Equipment • Capacity: • 8,000 MBH on CAT I Appliances • 15,000 MBH on CAT IV Appliances
RSIF Power Venter • Rated to 400°F non-condensing applications • Forward inclined impeller. Statically and dynamically balanced. • Insulated housing in galvanized steel • Hinged fan housing easily opens to provide easy access to duct and impeller • Direct drive, variable speed, TEFC motor located outside housing for easy access • Capacity: • 1,800 MBH on CAT I Appliances
Controls • EBC30 – Modulating Pressure Control
Controls – EBC30 Features • 100% microprocessor based control • Plug-and-Play initialization process • Integrated PDS function with adjustable time delay • Intermittent or continuous operation for all fans • Field-adjustable PID loop • Priority Operation function • Bearing Cycle function • Rotation Check for three-phase fans
Controls – EBC30 More Features.. • Controls up to six appliances standard • Add-on single-phase motor speed control available • Add-on relay board for four additional appliances • Customizable Pre and Post-Purge cycles • Manual Override • Alarm Relay output • RS 232 Port • 2 x 16 character alphanumerical backlit display
Controls – EBC30 Applications • CASV Chimney Automation Systems (All Appliances) • MCAS Modulating Air Combustion Supply • MODS Modulating Overdraft Damper System • (MDVS Modulating Dryer Venting System) • Any Combination of the Above!
EBC 30 Control - Design Fan Control Module (optional) Main Board Display and processor Relay Module (optional)
Controls Applications • CASV Chimney Automation Systems (All Appliances) • MCAS Modulating Air Combustion Supply • MODS Modulating Overdraft Damper System • (MDVS Modulating Dryer Venting System) • Any Combination of the Above! PDS – Proven Draft Switch
Controls EBC 12 Pressure Control Controls RSV, RSIB and RSIF Fans Controls three-phase fans using a VFD Activates on 10-120 V AC or DC signal Built-in proven draft logic Time delay and active response to avoid nuisance alarms Post-Purge cycle Single appliance applications
EBC10 • For Single-Stage or Draft Hooded Appliances • For Gas Fireplaces • Controls RSV, RSIB, RSIF, GSV • Provides 10-120V to fan or 0-10V to VFD • Built-in Fan Speed Control • Time delay and active response to avoid nuisance alarms • Pre and Post - Purge
Controls EBC12X – Motor Power Relay “Slave” motor speed control Will operate additional fans at the same speed as the fan connected to the ECB30 LED’s for easy setup and troubleshooting
Controls ES12 – Relay Box Extension for EBC10 input and output to appliances Up to four appliances per unit Can be connected in multiples for more than four appliances Accepts 10-120 V AC or DC for thermostat input LED’s for easy setup and troubleshooting
Controls VFD – Variable Frequency Drive Pre-programmed from the factory 1 – 5 HP in 200 Volt Class input 1 – 7. All wiring is done externally – conduits and wires are pre-installed Quick-menu for field adjustable parameters NEMA 1 rating
Products - Accessories SCA – Steel Chimney Adapter Steel chimney adapter Used as transition between a round stack and the fan Made of 304 stainless steel
Aluminum Plenum Boxes • Frame constructed of extruded aluminum; covered with aluminum panels • Watertight silicone seal • Corrosion resistance • Adapters used to connect to any flue size • Stock standard parts, assemble as needed with shorter lead time • Easily expanded for 3-4 fan plenum • Weight reduced
Products- Accessories BBM – Balancing Baffle Balancing baffle with male connections for single wall stack and B-vent 16 GA galvanized steel construction For balancing pressure drops on systems with multiple appliances
Products- Accessories BBF – Balancing Baffle Balancing baffle with flange connections for positive pressure stacks For balancing pressure drops on systems with multiple appliances
CASV Chimney Automation Systems APPLICATIONS
CASV Applications – Stack Downsizing / Energy efficiency St. Lukes Hospital, Kansas City
CASV Applications – Stack Downsizing / Energy efficiency St. Lukes Hospital, Kansas City
CASV Applications – Stack Downsizing Hazen High School – Renton, WA Soldier Field - Chicago, IL
CASV Applications – Stack Downsizing Casino Magic-Bay, MS Miami Condos, FL
CASV Applications - Aesthetics Getty Center – Los Angeles Rigel – San Francisco
CASI Applications Steinbach Credit Union, Winnipeg, SK
MCAS Components – SFTA Fan Seven Models 1,500 – 30,000 cfm • Fan can be mounted indoors • Impeller – cast aluminum. • Housing in steel • Direct drive, variable speed, totally enclosed motor • Variable Frequency Drive is used on three phase models (VFD should be located inside the building).