Dump in case of MKDV flashover. Flashovers in the magnets will cause different total peak current depending on where this happens The resulting deflection is between half the nominal (one complete MKDV missing) or double the nominal (one complete MKDV more) one
E N D
Dump in case of MKDV flashover • Flashovers in the magnets will cause different total peak current depending on where this happens • The resulting deflection is between half the nominal (one complete MKDV missing) or double the nominal (one complete MKDV more) one • With Q26 optics, above 47.5 kV the beam is on the graphite block, considering only half MKDV deflection • With Q20 instead, this is not the case anymore! (not even with 52 kV)
Dump in case of MKDV flashoverHalf deflection from MKDV MKDV at 52 kV MKDV at 47.5 kV