1 / 1

Development of Picosecond-Resolution Large-Area Time-of-Flight Systems

Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley 2 , J. Anderson 1 , K.Byrum 1 , G.Drake 1 , H.Frisch 2 , J. Genat 2 , H. Sanders 2 , F.Tang 2 , J. Va’vra 3. Abstract

camdyn
Download Presentation

Development of Picosecond-Resolution Large-Area Time-of-Flight Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley2, J. Anderson1, K.Byrum1, G.Drake1, H.Frisch2, J. Genat2, H. Sanders2, F.Tang2, J. Va’vra3 Abstract The measurement of time-of-flight (TOF) of relativistic particles in high-energy colliders with psec resolution would qualitatively change the ability to identify underlying parton-level processes at future colliders or upgrades of existing detectors. We are exploring a psec-resolution TOF system using micro-channel plates (MCP's) incorporating: a source of light with sub-psec jitter, in this case Cherenkov light generated at the MCP face (i.e. no bounces), short paths for charge drift and multiplication, a low-inductance return path for the high-frequency component of the signal, optimization of the anode for charge-collection over small transverse distances, and the development of multi-channel psec-resolution custom readout electronics directly mounted on the anode assembly. Micro-Channel Plate PMT The “Mark-1” is a 1024 anode 10um pore micro-channel plate photo-multiplier tube. We are testing charge collection schemes by clamping the board to the tube and putting a conductive elastomer between them. The commercial tube is a 25um pore 64 anode tube from Photonis. It has a commercially available collection scheme. The “Mark-P” is also a 25um 64 anode tube. It has some improvements, including a new ground plane to reduce ringing. Results The “Mark-1” in the clamp with a new collection scheme. We have measured the timing properties of two MCP-PM’s from Photonis. The two 64-anode 25-micron pore tubes have a commercially available collection scheme and were used to find a limit on the timing resolution. The system was calibrated before the measurements were taken. Here we show a comparison of a red laser (635nm) and a blue laser (408nm). The discontinuity in the 635nm graph is caused by a change in attenuation. The commercial tube with a small board tying 4 anodes together. The anode side of the “Mark-1”. All of the anodes on the “Mark-P” are grounded except for the one being read out. Collection Anode The first collection scheme that was tested tied 256 anodes together. After attaching it to the Mark-1 the capacitance was measured to be 11pF using time domain reflectometry (TDR). This helped explain the slow decay time in the pulse. Laser Test Stand at Argonne A dark box was constructed at Argonne National Laboratory to test the MCP’s. It uses a Hamamatsu laser to illuminate the MCP’s and commercial electronics to measure the timing resolution and collected charge. The intrinsic jitter of the system is ~4ps and it has a resolution of 3.13ps. Histogram using the 408nm laser set at ~50pe. TDR Results: 256 = 11pF Histogram using the 635nm laser set at ~55pe. Lens to focus beam on MCP Ch 1: Commercial (5mV/div) (2ns/div) Ch 2: Mark-1 (5mV/div) 256 – pixels tied together (~26mm) 1 – pixel (~6mm) 2.29kV 1.67kV MCP 2 Mirrors to delay light. Ch 1: Yellow Ch 2: Blue The second collection scheme we tested read out groups of 16, 9, 4, and 1 anode. The board was attached to the Mark-1 and the capacitance was again measured using time domain reflectometry (TDR). The board was not correctly aligned causing loss in gain. We are currently working on a new way to attach the collection scheme to the “Mark-1”. Conclusion We have measured the timing resolution of two MCP’s using a newly assembled test-stand based on a Hamamatsu PLP-10 picosecond laser and a commercial CAMAC readout electronics system. We have developed a new collection scheme to be attached to a 1024 anode MCP. The capacitance and gain of the MCP and board were tested. X-Y Stager 50/50 Beam Splitter MCP 1 TDR Results : 1 = 1.2pF, 4 = 1.5pF, 9 = 2.3pF, 16 = 2.8pF Ch 1: Mark-1 (5mV/div) (2ns/div) Ch 2: Commercial (5mV/div) 9 – pixels tied together (~6mm) 1 – pixel (~6mm) 2.29kV 1.67kV PSEC is a collaborative effort between groups at Argonne National Laboratory1, University of Chicago2, and the Stanford Linear Accelerator Center3. Ch 1: Yellow Ch 2: Blue

More Related