Performance. under fire condition. New requirements for circuit integrity: enhanced cables. BS 5839-1 : 2002 Fire Detection and Fire Alarm Systems for Buildings Part 1: code of practice for system design, installation, commissioning and maintenance

chars
Download Presentation

Performance

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Performance under fire condition New requirements for circuit integrity: enhanced cables BS 5839-1 : 2002 Fire Detection and Fire Alarm Systems for Buildings Part 1: code of practice for system design, installation, commissioning and maintenance Par. 26 Cable, wiring and other interconnections Recommendation for two level of fire resistance: • Standard for general use • Enhanced when cables might need to operate correctly during a fire for periods in excess of those normally required for single phase evacuation of building

  2. Performance under fire condition New requirements for circuit integrity: enhanced cables BS 5839-1 : 2002 Standard EN 50200 PH 30 classification (improved) 830 °C mechanical shock for 15 min. mechanical shock and water for 15 min. Enhanced EN 50200 PH 120 classification (improved) 930 °C mechanical shock for 60 min. mechanical shock and water for 60 min.

  3. Performance under fire condition New requirements for circuit integrity: enhanced cables BS 5839-1 : 2002 Regarding fibre optic cables, “When fibre optic connections are used, they need to provide at least equivalent integrity and reliability to other cables that are recommended for the same purpose”.

  4. Products SR 114E Control Cables 300/500 V These cables have been designed to meet requirements of BS 5839-1 : 2002 for enhanced cables for certain specific building applications. Standards: BS 6387 C W Z, BS 7629, SS 299 part 1, IEC 60331, IEC 60332-1, IEC 60332-3, IEC 60754-1, IEC 61034, EN 50200 PH120, CEI 20-35, CEI 20-36, CEI 20-37, CEI 20-38, CEI 20-22/3