1.32k likes | 2.07k Views
TURBINE GAS METERS. OPERATING PRINCIPLE. BODY. INDEX. COUPLING. TURBINE WHEEL. FLOW CONDITIONERS. BEARING BLOCK. MAIN SHAFT. OPERATING PRINCIPLE. IDEAL TURBINE. ERROR (%). 1. 0,5. 0. -0,5. -1. 0. 25. 50. 75. 100. 125. CAPACITY (%Qmax). IDEAL TURBINE GAS METER. REALITY.
E N D
OPERATING PRINCIPLE BODY INDEX COUPLING TURBINE WHEEL FLOW CONDITIONERS BEARING BLOCK MAIN SHAFT
IDEAL TURBINE ERROR (%) 1 0,5 0 -0,5 -1 0 25 50 75 100 125 CAPACITY (%Qmax) IDEAL TURBINE GAS METER
REALITY • DENSITY EFFECT • REYNOLDS EFFECT • PERTURBATIONS • DYNAMICAL PERFORMANCE • DIRTY GAS
DENSITY AND REYNOLDS EFFECT TURBINES (Non Optimized Turbine Meter) Error of Indication (%) 1 0,5 0 -0,5 air, atmospheric -1 0 25 50 75 100 125 Capacity (%Qmax)
DENSITY AND REYNOLDS EFFECT TURBINES (Non Optimized Turbine Meter) Error of Indication (%) 1 air, atmospheric natural gas, 1bar natural gas, 2bar natural gas, 4bar 0,5 0 -0,5 -1 0 25 50 75 100 125 Capacity (%Qmax) Natural gas 16 bar
DENSITY AND REYNOLDS EFFECT TURBINES (Optimized Turbine Meter) Error of indication (%) 1 Flat @ high Reynolds Numbers 0,5 0 -0,5 air, atmospheric -1 0 25 50 75 100 125 Capacity (%Qmax)
DENSITY AND REYNOLDS EFFECT TURBINES (Optimized Turbine Meter) Error of indication (%) 1 air, atmospheric natural gas, 1bar natural gas, 2bar natural gas, 4bar 0,5 0 Natural gas 16 bar -0,5 -1 0 25 50 75 100 125 Capacity (%Qmax)
HIGH PRESSURE TESTING @ RUHRGAS-LINTORF RUHRGAS-LINTORF LABORATORY • G400 DL80 Ansi 300 • Tested @: • 11 bar Natural Gas • 24 bar Natural Gas • 40 bar Natural Gas
PERTURBATIONS (REALITY) ERROR (%) 10 5 0 -5 -10 0 25 50 75 100 CAPACITY (% Qmax)
LOW LEVEL PERTURBATIONS CALIBRATION
CALIBRATION CONDITIONS Pigsar, Germany Straight inlet sections with pipe bundles
EN12261, ISO, OIML TYPE APPROVAL DEFINED PERTURBATIONS / MAXIMUM ERROR SHIFT < 0.3% LOW LEVEL PERTURBATIONS HIGH LEVEL PERTURBATIONS
INTERMITTENT FLOW • Heating, cooking • Boilers CAPACITY + + TIME ERROR UP TO 30% (+)
INTERMITTENT FLOW CAPACITY + + TIME + + Error =
PULSATING FLOW - Regulator - Compressor capacity + + + + Errors up to 5% (+) Time
HIGHEST LOAD LOWEST LOAD Q Q max min Winter Summer Monday Morning Weekend at Night RANGEABILITY
RANGEABILITY TIME (CUMULATIV) 1000 FREQUENCY DISTRIBUTION CONSUMPTION 2003 FREQUENCY DISTRIBUTION CONSUMPTION 2005 800 600 REGULAR CHECK OF CONSUMER LOAD IS REQUIRED! 400 200 0 0 25 50 75 100 125 150 CAPACITY (%Qmax)
Density (real) Range (reality) = 0,8 . range (Atm. Air) . Density (Atm. Air) RANGEABILITY Pressure (bar) Density (Kg/m3) Rangeability Atm. AIR 1,2 1:20 8 bar NATURAL GAS 7,2 1:30 13,6 1:50 16 bar NATURAL GAS 25 bar NATURAL GAS 20,8 1:65 32,8 1:80 40 bar NATURAL GAS 60 bar NATURAL GAS 48,8 1:100
RANGEABILITY F F F LOW PRESSURE NATURAL GAS
RANGEABILITY F F F HIGH PRESSURE NATURAL GAS
RANGEABILITY HIGH PRESSURE NATURAL GAS LOW PRESSURE NATURAL GAS
Density (real) Range (reality) = 0,8 . range (Atm. Air) . Density (Atm. Air) RANGEABILITY 20 : 1 @ Atmospheric Air 10 : 1 @ Atmospheric Air 20 : 1 @ 8bar Natural Gas
Density (real) Range (reality) = 0,8 . range (Atm. Air) . Density (Atm. Air) RANGEABILITY Pressure (bar) Density (Kg/m3) Rangeability Atm. AIR 1,2 1:20 8 bar NATURAL GAS Max. 1 : 30 7,2 1:30 13,6 1:50 16 bar NATURAL GAS 25 bar NATURAL GAS 20,8 1:65 32,8 1:80 40 bar NATURAL GAS 60 bar NATURAL GAS 48,8 1:100
RANGEABILITY IMRM TWIN > 1 : 160
LONG TERM STABILITY (DRIFT) 2 ERROR(%) 1 Drift 0 -1 -2 TIME
LONG TERM STABILITY (DRIFT) • CONSTRUCTION (DESIGN): • LUBRICATION AND FLUSHING OF THE BALL BEARINGS • SIZING AND POSITION OF THE MAIN BALL BEARINGS (DEPENDING ON PRESSURE RANGE) • AXIAL LOAD COMPENSATION (ALC) • PROTECTION OF THE MAIN BEARINGS (DEBRIS) • - ALUMINUM TURBINE WHEEL • TRANSPORTATION: • SHOCK LOADS • ALUMINUM METER BODIES (LOW WEIGHT) • SEPARATE TRANSPORT METER BODY / CARTRIDGE • STARTING UP: • PRESSURE SHOCKS • OVERLOAD • OPERATION: • - CONDITION OF THE GAS (DEBRIS AND MOISTURE) • OVERLOAD
QUALITY OF THE GAS / DIRT 1% -1% DIRT IN THE BEARINGS INCREASES MECHANICAL FRICTION
QUALITY OF THE GAS / DIRT 1% -1% DIRT ON THE TURBINE BLADES INCREASES THE SPEED
QUALITY OF THE GAS / DIRT DIRT ACCUMULATION
SEPERATION OF FUNCTIONS (OIML) FUNCTIONS SENSOR INDEX COMMUNICATIONS
IMTM CONCEPT INDEX GEAR BOX (ADJUSTMENT) CARTRIDGE MULTI STAGE FLOW CONDITIONER
IMTM TURBINE GAS METER PULS BOX MULTI FUNCTIONAL INDEX ADJUSTMENT GEARS ADJUSTMENT GEARS GEHAEUSE CARTRIDGE HF PULSER OIL PUMP PR-POINT REMOVABLE RAISE FACE RING THERMOWELL
EXCHANGEABLE CARTRIDGE EXCHANGEABLE CARTRIDGE • FAST AND EFFICIENT REPAIR AND CALIBRATION • FAST AND SECURED TRANSPORTATION • ON SITE EXCHANGEABLE • HIGH PRESSURE CALIBRATED CARTRDIGE ON STOCK