An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Biphasic Defibrillator BDFM-1000D www.medzer.com | info@medzer.com

  2. Specifications : Energy selection 2, 5,7,10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J Charging time 3 hours minimum of continuous ECG Monitoring, Display 7-inch LCD High resolution ECG Lead selection: Displayed in monitor, paddles, I, II, III, AVR, AVL, AVF, V 3-lead, or 5-lead ECG cable, Heart rate: 20 – 300 BMP Smart Alarms: Beeper/voice prompts indicate shockable rhythm Sweep Speed 25 mm/sec

  3. SpO2 Measurement Range: 30 – 100 %, +/-2% between 80% - 90%, others +/- 5 % Alarm range: User set high and low limit Alarm Accuracy: +/- 10% within setting values Alarm time Accuracy: less than 12 sec PR Range: 0bpm ~ 255 bpm Power supply AC : 100 V ~ 240 V, 50 Hz / 60 Hz Vehicle voltage (option) DC ~ 12 V Alarm Heart Rate Alarm: On/Off display on monitor, user selectable Smart Alarms: Beeper/voice prompts indicate shockable rhythm

  4. AED Mode Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts Ventricular fibrillation with amplitude = 200 μ Ventricular tachycardia with rates = 140 bpm QRS complex wave duration =140 ms Charge control: control on device front panel, press key on paddle.

  5. Battery Rechargeable, Ni-MH battery, 12V Operation time: For a new, fully charged battery discharges 60 defibrillator. Or 3 hours minimum of continuous ECG Monitoring, Additional parameters affect operating time with different functions. Weight 12 kgs Features : 7-inch LCD display Defibrillation : Manual, Synchronized and Asynchronous Synchronized Mode: Synchronize defibrillator pulse to patient’s R- wave. Printing method: High-resolution, thermal array print head Information: Heart rate, Lead/Pads, Alarm With pacemaker

  6. Medzer Inc Brandy Wine, 1000 N West St, Wilmington, DE 19801, United States Email: info@medzer.com | Website: www.medzer.com