Mission in Critical ADAM-4100 Robust Series. Critical Design Concepts. Wide Operating Temperature Wide Applications Coverage Anti-Surge / Anti-Noise Smart Field Indicator Dual Protocol Support Value-added functions. ADAM-4100 Robust Series. ADAM-4168
E N D
Critical Design Concepts • Wide Operating Temperature • Wide Applications Coverage • Anti-Surge / Anti-Noise • Smart Field Indicator • Dual Protocol Support • Value-added functions
ADAM-4100 Robust Series ADAM-4168 Channels: 8 Form A Relay Output Contact Rating: AC:125V@0.6A; 250V@0.3A DC:30V@2A; 110V@0.6A Breakdown Voltage : 750 VAC (50/60 Hz) Relay response Time: ON :3 ms Off: 1 ms Dual Watchdog Timer ADAM-4117 Channels: 8 differential AI Resolution: 16-bit 200VDC High common mode lnput Type: mV, V, mA Sampling Rate: 10/100 samples/sec Dual Watchdog Timer TVS/ESD Protection ADAM-4118 Channels: 8 differential AI Resolution: 16-bit Input type & range: Thermocouple: J/K/T/E/R/S/B Voltage mode: mV, V Current mode: mA Sampling Rate: 100 samples/sec. Dual Watchdog Timer TVS/ESD Protection ADAM-4150 Channels: 7 DI / 8 DO Digital Input: - Support Dry/Wet Contact: - Support 1 KHz counter Digital Output: - Open drain to 40 V, 0.8A max. - Support pulse output Dual Watchdog Timer 3000VDC Isolation voltage
< 85oC -40oC < Wide Operating Temperature / Application Coverage Wide Operating Temperature Wide Power Source Range < 48 VDC 10 VDC <
Anti-Surge / Anti-Noise 200VDC High Common Mode Voltage against channel voltage deviation Configurable Digital Filter against micro contact error 3 KV EFT (Electrical Fast Transient) Protection against Magnetic Noise Auto-tuning Filter against external Noise 3KV ESD (Electrostatic Discharge) Protection Against Electrostatic Damage 50Hz/60Hz Filter against Power Noise 1 KV Power Surge Protection
Smart Field Indicator Mode Switch Front Side View Normal Mode Channel Status Indicator Address Mode Node ID Indicator (Switch to initial mode) Get Channel Status / Address information easily !!
Modbus Protocol • HMI S/W with… • Modbus Driver • Modbus OPC Server Modbus/RTU Modbus/TCP ADAM 4572 HMI Server (Modbus/RTU) Modbus Ethernet Data Gateway Modbus Controller Dual Protocol Support • ADAM Protocol Host PC With User’s APs ADAM ASCII Commands ADAM-4000 Modbus I/O
Multi-channel / Multi-range ADAM-4117 ADAM-4118 V, mA, mV, T/C V, mA, mV, T/C 4-20 mA 0-10 V 0-5 V T/C K Allows multi-range setting in one module Only one range setting in one module Value-added Functions • Open Wired Diagnostic ! x ADAM-4118 T/C Input Module Sensor • Dual Watchdog Timer System Watchdog ADAM-4150 ADAM-4168 ADAM-4117 ADAM-4118 Comm. Watchdog