An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. System SpecificationsLab Tests KFPA CDR Jan 30-31, 2009 System Specs KFPA CDR Jan 30-31 2009

  2. General RequirementsLab Results • Frequency Range: 18-26.5 GHz; goal 17-27.5 GHz with degraded performance. • Instantaneous Bandwidth: 1.8 GHz minimum. • Noise Temperature: 36 K maximum 18-26.5 GHz; 25K maximum over 75% • Polarization Axial Ratio: 1 dB maximum • Polarization Isolation: 25 dB minimum (within a pixel). • Pixel-Pixel Isolation: 30 dB minimum • Output Flatness: 3dB p-p maximum • Linearity: 30 dB below 1dB point at 300K System Specs KFPA CDR Jan 30-31 2009

  3. Frequency Range System gain falls off rapidly outside 18-26.5 GHz and noise temp increases, but might be usable just outside for some applications. System Specs KFPA CDR Jan 30-31 2009

  4. Frequency Range Of the cooled components, the OMT limits the upper frequency. System Specs KFPA CDR Jan 30-31 2009

  5. Noise Temperature Receiver noise is less than the current K-band rx, and Tcal varies more smoothly. System Specs KFPA CDR Jan 30-31 2009

  6. Axial Ratio Measurements Measured axial ratio is well less than the 1dB spec. System Specs KFPA CDR Jan 30-31 2009

  7. Isolation • Polarization Isolation • Prototype IDM1 has low isolation at some frequencies that will be corrected. • OMT polarization isolation >35 dB • Pixel-Pixel Isolation not yet measured. • Have checked thermal gaps and are OK. System Specs KFPA CDR Jan 30-31 2009

  8. Gain Flatness Measured thru dewar and IDM-2. Ripple originates inside the dewar, mismatch error between LNA output and waveguide window thru ~40cm interconnecting wg. System Specs KFPA CDR Jan 30-31 2009

  9. Linearity IDM variable attenuators before final IF amps allow adjustments. With min atten, Tsys=100K, we’re ~25dB below P1db. System Specs KFPA CDR Jan 30-31 2009