1 / 14

Heaters for the cooling system tests (lab modules)

Heaters for the cooling system tests (lab modules). A. Samoshkin Last update 04- Apr -2011. t° sensors ( half – module Type0 ). MB. DB. T. T. T. T. T. T. T. T. T. T. T. T. T. T. Module Type 0 cooling scheme. 25˚C. 35˚C. DB magnets heating.

maylin
Download Presentation

Heaters for the cooling system tests (lab modules)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Heaters for the cooling system tests (lab modules) A. Samoshkin Last update 04-Apr-2011

  2. t° sensors ( half – module Type0 ) MB DB T T T T T T T T T T T T T T

  3. Module Type 0 cooling scheme 25˚C 35˚C

  4. DB magnets heating We were planning to use the 220V - 200W heaters, and every mockup mounts 8 of them. We have chosen such a high power to reduce the time needed to warm up the mockup (1600W should warm up the 170 kg of steel in less than 10 minutes). Anyway, if is not convenient to deliver that much power it is possible to use lesser heating and pay that with some extra time during the warm-up phase.

  5. Power dissipation by T0 Lab Module components 150 W 110 W 410 W 410 W 410 W 410 W 110 W 410 W 410 W 410 W 410 W 110 W 150 W 110 W * DB Q DB Q PETS  440 W DB Q  300 W AS  3280 W * Technical Specification for the CLIC Two-Beam Module G. RIDDONE EDMS 1097388 TH Table

  6. Heaters for PETS and AS (Suggestion) Ø 8 508 mm Ø 8 2024 mm

  7. HOTWATT (USA) Contact: Felix Meyer Sibalco AG, Birmannsgasse 8, 4055 Basel, Tel.: +41 61 264 10 10, Fax: +41 61 264 10 15, f.meyer@sibalco.ch, www.sibalco.ch Ø 8 Ø 11,2 4064 Herewith the cost from parts alone, none packed, ex factory Hotwatt USA, without packing and transportation costs. (Price based on min. 2 pcs.) TC31-160/6800W240V/SF3S CHF 285.00 / PCS TC44-160/6800W240V/SF3S CHF 308.00 / PCS Packing-case and freight charge from Hotwatt work to CIF-Switzerland: CHF 1200.- Lead time 6-8 weeks (~ 6 weeks for manufacturing + ~2 week for delivery). Phone conversation 15-Mar 16:00  no control unit supplied. Official offer must be issued by 17-Mar-2001 Offer received 16-Mar 11:59  Clarification on required total qty of units and order them

  8. Heaters for T0 Test Module Max 3050 W max 480 W max 480 W 1600 W 1600 W • - Two 20” (508 mm) long heaters for DB (PETS) • One 80” (2024 mm) long heater for MB (AS) • Sixteen 200W cartridges for DB (Quads)

  9. Heaters for DB & MB (two test modules Type 0) • Four 20” (508 mm) long heaters for DB  Max 480 W, 240 V, Ø 11,176mm, steel • (Ref: TS 44-20/480W240V/SF3S) • Two 80” (2032 mm) long heater for MB Max 6100 W, 240 V, Ø 11,176mm, copper (Ref: TS 44-20/480W240V/SF3S) • Thirty two 200W cartridges for DB Quads !  C= 5/8”=16 mm The power leads need some space and wires should pass out To 3D

  10. Two modules (optional configuration) ? - Two 160” (4064 mm) long heaters for MB & DB ~6900 W (copper sheath) and ~4400 W (steel sheath)

  11. 3D Integration layout Back

  12. TUBULAR HEATERS HOTWATT (USA) Power Dissipation Scheme

  13. Test Module Type 0 cooling scheme

More Related