1 / 14

Long Haul Ethernet (1) and Test of CERN grid software (2)

Long Haul Ethernet (1) and Test of CERN grid software (2). David Simonsen Project manager, UNI-C Denmark. Network status, Denmark. Government funding ended 1 st of jan. 2003 Now deploying upgrade (622 Mbps + 1 x 100 Mbps  2 x 1 Gbps (Ethernet))

clive
Download Presentation

Long Haul Ethernet (1) and Test of CERN grid software (2)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Long Haul Ethernet (1) andTest of CERN grid software (2) David Simonsen Project manager, UNI-C Denmark

  2. Network status, Denmark • Government funding ended 1st of jan. 2003 • Now deploying upgrade (622 Mbps + 1 x 100 Mbps  2 x 1 Gbps (Ethernet)) • One cross country, dark fiberpair for testing • No production traffic on fibers

  3. 10 GE, non regenerated • Goal: • To test the range of 10 Gbps Ethernet • Experimental constrains: • Pure Ethernet only • (no SDH/SONET or other desturbances) • No signal regeneration (optical amplification only) • Standard single mode fibres • Why? • To make 10 GE more accesible (cheaper)

  4. 10 GE-project partners • COM Center, Denmarks Tech. University • Martin Nordal Pedersen • ESTA, ’Enabling Switching at 10 Giga and Above’ at CERN • Mikkel Olesen • Global Connect A/S • Forskningsnettet (NREN) • UNI-C

  5. BATM T6 8 x 1 Gbps (850 nm) 1 x 10 Gbps (1550 nm) Zenpack Optillion 40 km-range

  6. 525 km

  7. Results • A 525 km long, pure Ethernet connection was set up at 10 Gbps • A Bit Error Rate of ~10E-14 • No special tailored equipment used

  8. Grid software experiment Goals • To get first hand experience with the technology • To test the Grid-software from CERN • To make the most complicated setup • To rate the highest throughput possible

  9. Project partners • COM Center, Denmarks Tech. University • ESTA at CERN • Global Connect A/S • Forskningsnettet (NREN) • UNI-C • Niels Bohr Institute, University of Copenhagen • NorduGrid • Nordic Data Grid Facility • Southern University of Denmark • University of Aalborg • Computer Science Dep. at Uni. of Copenhagen • High Performance Computing to the North, Umeå • University of Trondheim, Norway • Centre For Subatomic Research, University of Alberta, Canada

  10. Software working princible

  11. Network setup

  12. Results • Maximum throughput: 3.3 gbps (link Odense – Lyngby) • We got first hand experience with both software and network setups and problems • A very complicated setup was atchieved