1 / 9

Status of field quality measurements at cold of the DS-MS SSS.

Status of field quality measurements at cold of the DS-MS SSS. S. Sanfilippo and W. Venturini. Status of the cold measurements in SM18 (600-series). Results of MQY measurements in SM18. Conclusions. 6XX magnetic measurements strategy for 2006. Measurements outside SM18:

cooper
Download Presentation

Status of field quality measurements at cold of the DS-MS SSS.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of field quality measurements at cold of the DS-MS SSS. S. Sanfilippo and W. Venturini. • Status of the cold measurements in SM18 (600-series). • Results of MQY measurements in SM18. • Conclusions.

  2. 6XX magnetic measurements strategy for 2006. • Measurements outside SM18: • At room temperature with QIMM (ACCEL, TESLA,CERN) • At cold in Block 4 with long rotating coil for multipoles (MQMC, MQM,MQY). Correlation:Warm Cold Block 4 • Measurements in SM18 • MQY not measured in block 4 (Gdl for all) +few MQY already measured in block 4 (re-scale the abs.value of TF and checks of bn) • Gdl measurements on MQML to refine the w/c. • Relative variation with current for injection value and statistics for the spread, both measured in Block 4. • Magnets selected following the priority optics (list approved by the FQWG). Correlation:Warm Cold SM18+ cold data for MQY.

  3. Magnetic measurements executed in SM18 (End august 06). 15 S4 measured from the list endorsed by FQWG in March 2006. • 10 MQY type, 3 MQM type, 1 MQML type. • Almost all MQY measured (apart SSS671). • Test of SSS682 (6MQTLH) stopped, replaced by SSS680. • The proposal will be strictly followed till the end of the tests. • MQTLH: plan to measure SSS679, SSS682 and SSS677. (at least Gdl).

  4. Magnetic measurements on MQM and MQY. • Quantities measured for the main magnet: • Main field integral strength (rotating coil, SSW), magnetic length, as a function of the current. • Integrated and local harmonics as a function of the current (rotating coil). • Decay of the main field and of the multipoles after a reference cycle (rotating coil). • Two measurement cycles (ex MQY): Reference cycle for decay. 3610 A 3610A 3610 A 1000 s saturation 2000 A Geometric Quench 1000 s magnetization 176A 176 A Simulated Machine Cycle with a reference pre-cycle. Load-line (static measurements) Measurements performed after the training of the magnet.

  5. Results for MQY (TF, b6) measurements at 4.5 K. Decay of the TF. b6=F(current) TF= F(current)

  6. Results for MQY (TF, b6) measurements at 4.5 K. b6 Transfer Function DTF (injection-nominal) ~77 units From Block 4 :DTF (injection-nominal) ~75 units Results are in accordance with the measurements in block 4.

  7. Warm to cold correlation for MQY (TF) at nominal field. Slope 1 • Data measured with the same mole. • Offset to be recomputed after mole re-calibration (expected ~ +30 units). • 2 families : MQYs with high m?

  8. Warm to cold correlation for b6 at injection. Slope 1 • Graph to be completed with all the remaining warm data. • 2 families : MQYs with high m? • Offset – lower than computed using the block 4 measurements

  9. Conclusions. • Measurements on S4 are proceeding well, according the list proposed. • Reserve magnets: Priority given to the TF of all the 3 remaining cold masses containing the MQTL. • Results obtained for the MQY confirmed the values in Block 4 • They are not completely understood (w/c families, b2 decay). However enough to start the modeling process (FIDEL). • The SSS661 (Q5R6) has been added to perform changes of injection current. The other special tests will be carried out in block 4 (see W. Venturini program).

More Related