1 / 35

Photoelectric Beam Detector

Photoelectric Beam Detector. NRTS Series. 1. Outline. Dual beam detector NRTS series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *6 0m 120m 180m (Indoor) range. 2. Functions & Features. Two Beams (2) High Grade Spherical Fresnel Lens

corby
Download Presentation

Photoelectric Beam Detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Photoelectric Beam Detector NRTS Series

  2. 1.Outline Dual beam detector NRTS series is a part of Red Barrier series. *30m 60m 90m (Outdoor) range *60m 120m 180m (Indoor) range

  3. 2.Functions & Features • Two Beams (2) High Grade Spherical Fresnel Lens ① Sharp focused beam ray (a) Allows 100 times sensitivity (b) Minimizes unnecessary beam reflection. (c) Minimizes receiving unnecessary external light. ② Cut the unnecessary external lights ③ Integrated optical scope (a) Matches beam and scope direction (b) Shows the clear sharp target

  4. (3) 100 times sensitivity allowance (4) Easy optical alignment (5) IP rate : IP55 (6) Adjustable Beam Interruption Time (7) AGC (Auto Gain Control) (8) Unique Knockout Structure (9) Mount bracket (10) Heater (Option)

  5. (1) Twin Beams offers stable Operation When the bugs, falling leaves or other flying objects block the one beam, other one beam still can keep unit correctly without making false alarms.

  6. (2) High Grade Spherical Fresnel Lens Transmitter Receiver Lens

  7. ①The sharp focused beam ray at long distance achieves (a)100 times sensitivity allowance. This high grade lens focuses the beam ray on the receiver without the big beam power loss. * Refer to (3) for further detail.

  8. Focused beam diameter

  9. (b) Minimize unnecessary beam reflection NRTSLens

  10. NormalLens

  11. (c) Minimizes receiving unnecessary external light.

  12. ② Cut the unnecessary external lights

  13. ③ Integrated optical scope (a) Matches beam and scope direction The beam and scope direction is same and fixed as the scope is integrated on the lens. Transmitter Receiver Scope

  14. (a) Matches beam and scope direction The beam and scope direction is same and fixed as the scope is integrated on the lens. Scope direction Easy to align Beam direction Difficult to find the target

  15. (b) Shows the clear sharp target The well designed scope offer the very clear target image. Therefore it is very easy to align the optics. Clear image Unfocused image

  16. (3) 100 times sensitivity allowance Stable operation is maintained even if99%of beam power is lost by rain, snow, fog, dust or other objects.

  17. (4) Easy Optical Alignment (a) Scope for Rough Alignment

  18. (b) LED Level Indicator for Fine Alignment LED

  19. (c) Tester Level for Fine Alignment 3.0500

  20. (5) IP55 (Ingress Protection Rate) IP55 : Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact

  21. IP55: Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects. *Test duration: at least 3 minutes *Water volume: 12.5 liters per minute *Pressure: 30 kN/m² at distance of 3m

  22. (6) Adjustable Beam Interruption Time It is 50 mSec to 700 mSec . It is selectable according to the application.

  23. (7) AGC (Auto Gain Control) Control the Alarm Level according to the receiving Beam Power. If the receiving Beam power reduced very much in a short time, it could make Alarm even if Beam power is not blocked 100%. It means the unit always keeps the suitable alarm level automatically. This clever NRTM is always watching the receiving beam power and changes the alarm level to keep stable operation.

  24. (8) Unique Knockout Structure It is not necessary to cut the cover for making the knockout hole. The base has the enough height to make the knockout hole for wiring. It keepsIP55for any application.

  25. (9) Pole mount bracket • This is used for the pole installation. • Without this mount bracket, the chassis bends and it makes the installation difficult.

  26. Chassis Mount bracket Pole

  27. (10) Heater (option) NRTM works down to – 25 °C . But for the stable operation under the cold temperature below – 10 °C , this heater is very useful as the it warm up the inside of unit. 2 pieces are one set.

  28. Heater

  29. 3. Installation case (1) Factory

  30. (2) Warehouse

  31. (3) Home

  32. 4. Specifications

  33. Thank you ! Atsumi Electric Co.,Ltd.

More Related