210 likes | 504 Views
AVEQ. Analysis of Tocopherols/Tocotrienols and Avenanthramides in Oats WP 8 Rita Redaelli and Lena Dimberg. Tocopherols/ Tocotrienols. Tocopherols. Tocotrienols. Extraction of Tocopherols/Tocotrienols. Pisacane et al., 2004 Solvent: Methanol Flour/solvent ratio: 1 g/14 ml
E N D
AVEQ Analysis of Tocopherols/Tocotrienols and Avenanthramides in Oats WP 8 Rita Redaelli and Lena Dimberg
Tocopherols/ Tocotrienols Tocopherols Tocotrienols
Extraction of Tocopherols/Tocotrienols Pisacane et al., 2004 Solvent: Methanol Flour/solvent ratio: 1 g/14 ml Time: 2*1 min Solubilized: Methanol (or hexane/1,4-dioxane, 95/5) Peterson et al., 2007 Solvent: Methanol (or saponified KOH in ethanol + antioxidant) Flour/solvent ratio: 1 g/28 ml Time:2* 20 min Solubilized: Hexane (or hexane/2-propanol, 99.5/0.5) SLU-lab Solvent - Methanol Flour/solvent ratio:(1 g/21 ml) Time: 3*20 min Solubilized - Hexane Nielsen and Hansen, 2008 Solvent: Hexane Flour/solvent ratio: 1 g/30 ml Time: 1* 10 min Solubilized: Hexane
HPLC analysis of Tocopherols/ Tocotrienols • Peterson et al., 2007 • NP- column: 250 mm • Isocratic solvent: • Hexane/2-propanol(99.5/0.5 v/v) • Flow: 1 ml/min • Time:? • Fluorescence detector: • ex 295 nm; em 330 nm • References: α-tocopherol • Pisacane et al., 2004 • NP- column: 250 mm • Isocratic solvent: • Hexane/1,4-dioxane(95:5 v/v) • Flow: 1,5 ml/min • Time: 11 min • Fluorescence detector: • ex 294 nm; em 326 nm • Reference: 8 isomers • Nielsen and Hansen, 2008 • NP- column: 125 mm • Isocratic solvent: • Hexane/ethylacetate/acetic acid(94.6/3.6/1.8) • Flow: 1 ml/min • Time: 16 min • Fluorescence detector: • ex 290 nm; em 330 nm • References: 8 isomers • SLU-lab • NP- column: 250 mm • Isocratic solvent: • Hexane/1,4-dioxane(96:4 v/v) • Flow: 1.5 ml/min • Time: 21 min • Fluorescence detector: • ex 294 nm; em 326 nm • Reference: 8 isomers
NP-HPLC OF TOCOLS Pisacane et al. 2004
Avenanthramides R= H, OH or OCH3 n= 1 or 2
HPLC-chromatogram (UV 340 nm) oat extract and reference compounds
Extraction of Avenanthramides Collins Solvent - 80% Ethanol (acidified) Flour/solvent ratio:(1 g/25 ml) Temperature: 100 C Time: 3*20 min Purification: Octyl-sepharose, Sephadex-LH20 Solubilized – 50% Ethanol Matsukawa et al., 2000 Solvent - Methanol Flour/solvent ratio:(1 g/30 ml) Temperature: ambient? Time: 3*? min Solubilized -Methanol SLU-lab Solvent - 80% Ethanol (pH 2) Flour/solvent ratio:(1 g/21 ml) Temperature: 50 C Time: 3*20 min Solubilized - Methanol Wise et al., 2009 Solvent: 80%Ethanol Flour/solvent ratio: 1 g/30 ml Temperature: 50 C Time: 3*20 min Solubilized: Methanol
HPLC analysis of Avenanthramides • Collins et al., 2004 • RP C-18 column: ? mm • Solvent: A. 5% acetic acid • B. methanol • Gradient: 40 to 100% B in A for 88 min • Flow: 0.8 ml/min • Time: 50 min • Diod array: 330 nm • Reference: ? compounds • Matsukawa et al., 2000 • RP C-18 column: 150 mm • Solvent: A. 0.5% TFA, • B. acetonitrile • Gradient: 15 to 30% B in A for 60 min • Flow: ? ml/min • Time: ? min • Diod array: 340 nm • Reference ? compounds • SLU-lab • RP C-18 column: 125 mm • Solvent: A. = 0.01 M formic acid • (pH 2.9), 5% acetonitrile • B. acetonitrile • Gradient: 5 to 38% B in A in 35 min • Flow: 1 ml/min • Time: 30 min • Diod array: 340 nm • Reference: 17 compounds • Wise et al., 2009 • RP C-18 : 50 mm • Solvent: A. 0.1% formic acid, 5% acetonitrile • B. acetonitrile, 0.1% formaric acid • Gradient: 13-30% B in A for 20 min • Flow: 1 ml/min • Time: 20 min • Diode array detector: 280 and 330 nm • References: 3 compounds
Analysis of Avenanthramides LC-MS a UV detection, 340 nm b-g Selective ion monitoring (SIM) detection [M+H]+ for 2c, 2p, 2f, 3f, 2pd and 2fd, respectively
Avenanthramides in crown rust susceptible and resistant cultivars
Radical scavenging activity of different avenanthramides 1 min 5 min
Radical scavenging activity of different avenanthramides 1 min 5 min
HPLC-chromatogram (UV-detection 340 nm) -oat extract and reference compounds-