1 / 17

Status of SPARC Undulator

Status of SPARC Undulator. F.Ciocci ENEA Fis-Mat. Undulator parameter set. * H= height t= thickness, w= width. Electron beam parameters. Numerical codes used for FEL simulations PROMETEO (ENEA) PERSEO (ENEA)

crita
Download Presentation

Status of SPARC Undulator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of SPARC Undulator F.Ciocci ENEA Fis-Mat

  2. Undulator parameter set * H= height t= thickness, w= width

  3. Electron beam parameters Numerical codes used for FEL simulations PROMETEO (ENEA) PERSEO (ENEA) PARSIFEL (ENEA-codice semi-analitico.) GINGER GENESIS

  4. FEL power evolution vs longitudinal coordinate z (lu = 2.8 cm, K = 2.1413, I = 100 A)

  5. Mechanical tollerances Deflection of the undulator support structure, induced by the weight and by the attraction between the undulator surfaces, determined by the magnetic forces Misalignment of the undulator pole faces with respect to mid plane axis

  6. Transverse misalignment of the undulator pole faces with respect to mid plane axis Misalignment of the undulator pole bars with respect to z axis

  7. Combined effect of the misalignment and of the deflection due to the magnetic forces on the evolution of the FEL power Effect of the induced deflection and misalignment on the evolution of the power of the fundamental and higher order harmonics d= 10mm f = 5 mrad.

  8. analysis of magnetic field errors • We have performed a numerical simulation of the effect on FEL power behaviour of the magnetic field errors due to the magnetic blocks characteristics. • We have assumed that the maximum deviation between the single block magnetization is 1% and 1° is the maximum deviation of the magnetization axis. • Assuming that the magnetizations of the single blocks and the relevant orientations have gaussian distributions, we find, that they are characterized by the rms values

  9. Pierce parameter conditions DT=k 0.3° C

  10. Undulator Technical specifications • Value of the on axis (peak) magnetic field B at a gap of 0.925cm 8.27 . 103G • R.M.S. relative peak magnetic field < 10-3 • First field integral < 0.5 G . m • Second field integral < 0.6 G . m2 • Accuracy of the single period to maintain the Phase locking Dlu along the undulator < 20 mm

  11. ACCEL Hybrid Undulator for DELTA

  12. TIME SCHEDULE

  13. Mechanical alignment of the sections Each section must foresee the necessary equipment to fulfil the following tolerances for the mechanical alignment of the complete undulator device • Maximum Error of transverse positioning (vertical and horizontal) 50 mm • Maximum Error of longitudinal positioning 50 mm • Maximum error of angular alignment (f) 5 mrad • Maximum error of angular alignment (q) 5 mrad • Maximum error of angular alignment (y) 100 mrad

  14. Sparc versus Sparx Current 2000 A Energy 1150 MeV Energy Spread 0.5 10-3 Emittances 1 mm mrad

  15. Power vs. z