1 / 5

Harmonics solenoid at 30kA

150Hz. 356mV rms. 338mV rms. 50Hz. 214mV rms. 600Hz. 106mV rms. |Z -1 | [dB]. 250Ω -1. 2.5mΩ -1. 1.83mHz. Harmonics solenoid at 30kA. EXAMPLE CASE (150Hz): |Y| at 150Hz = 2.5mS |I| at 150Hz = 338mV x 2.5mS = 0.845mA rms = = 1.2mA pk Tf = 0.5T / 31kA = 16.1 x 10 -6 T/A

cullen
Download Presentation

Harmonics solenoid at 30kA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 150Hz 356mVrms 338mVrms 50Hz 214mVrms 600Hz 106mVrms |Z-1| [dB] 250Ω-1 2.5mΩ-1 1.83mHz Harmonics solenoid at 30kA EXAMPLE CASE (150Hz): |Y| at 150Hz = 2.5mS |I| at 150Hz = 338mV x 2.5mS = 0.845mArms = = 1.2mApk Tf = 0.5T / 31kA = 16.1 x 10-6 T/A |B| at 150Hz = |I| at 150Hz x Tf = 19nTpk |Ein| coil 1m2 at 150Hz = ω x Σ x |B| = 18µVpk TB November 23th, 2004 - Fabio Formenti

  2. 40mV IEC 478-3/C 2mV 3.16mV IEC 478-3/C Solenoid Vdc + and – at 12kA 1mV At the power converter outputs; same spectrum for both polarities IEC 478-3/C specs for conducted noise very stringent (not for such large devices, but typically 25A-400V) High noise due to environment radiated noise  More filtering capacitors will be added Poorly shielded and earthed converter body  To be checked and improved TB November 23th, 2004 - Fabio Formenti

  3. 40mV IEC 478-3/C 2mV 3.16mV IEC 478-3/C 1mV Solenoid Vrb24 and Vrb26 at 12kA At the solenoid magnet inputs; same spectrum for both polarities Noise practically acceptable; large massive magnet body acts as good ground reference To be rechecked after added filtering capacitors at power converter TB November 23th, 2004 - Fabio Formenti

  4. TPC FE electronics inside solenoid Sum of chs 0,1,2,3 undersampling:100 MAGNET ON • Quadratic sum of noise contributions is: • 1.05 ADC counts [r.m.s.] • Mean value of sum of 4 chs baselines is: • 194 ADC counts Sum of chs 0,1,2,3 undersampling:100 MAGNET OFF • Same mean value • Practically same sigma Measurements by: R.Campagnolo, B. Mota, C. Gonzales TB November 23th, 2004 - Fabio Formenti

  5. Conclusions • Solenoid power has been characterized in harmonics, low and high spectrum EMC • Dipole also characterized similarly (all results will be on E.Coord. page) • Harmonics will not be a problem: • low induced magnetic field perturbations • frequencies lower than interest range (for IN P/A) • local power filters enough to cancel any residuals • Conducted noise EMC is practically already acceptable: • improve shielding and filtering of power converter body • Test of TPC FE electronics inside solenoid did not show any measurable noise • Due thanks for the help provided: • C. De Almeida Martins AB-PO  measurements on harmonics and EMC • W. Venturini and C. Giloux AT-MTM  consultation on magnetic tests • PH-ED TPC team  measurements with FE electronics TB November 23th, 2004 - Fabio Formenti