1 / 24

Basics of Perfusion Imaging With Dynamic Contrast MRI

Basics of Perfusion Imaging With Dynamic Contrast MRI. Larry Panych, PhD Brigham and Women’s Hospital. Contents. What is perfusion and why do we care about it? How can it be measured and what are the parameters? What MR approaches are used in perfusion studies?

cwinfrey
Download Presentation

Basics of Perfusion Imaging With Dynamic Contrast MRI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Basics of Perfusion Imaging With Dynamic Contrast MRI Larry Panych, PhD Brigham and Women’s Hospital

  2. Contents What is perfusion and why do we care about it? How can it be measured and what are the parameters? What MR approaches are used in perfusion studies? How is dynamic contrast data processed?

  3. Perfusion is the steady state delivery of blood to the tissue

  4. Elastic Arteries • Large arteries close to the heart • Expand and recoil with changes in blood volume • Relatively inactive in vasoconstriction • Can be viewed as simple elastic tubes • Muscular Arteries • Medium and smaller arteries • Less elastic, more smooth muscle • more active in vasoconstriction • distribute blood to specific organs • Arterioles • Lumen diameter less than .5mm • Coils of smooth muscle • Constriction/dilation controls flow of blood to capillary bed • Capillaries • Blood cells flow in single file • Average length is 1mm and diameter .01mm • Provide access to all cells in the body • Exchange materials between blood and interstitial fluid

  5. Much of pathology begins at the cellular and tissue level and is not accompanied by changes in macroscopic blood flow

  6. Some methods to image perfusion PET SPECT CT MRI

  7. MRI Perfusion Methods Bolus Tracking (T1 and T2) Steady State Techniques Arterial Spin Labeling

  8. Perfusion Parameters Blood Flow (ml of blood/gm of tissue/sec) Blood Volume (ml of blood/gm of tissue) Mean Transit Time (MTT) (sec) V = F MTT

  9. Bolus injection of paramagnetic agent (Gd) Contrast agent injected into vein Lung Arm Heart

  10. Susceptibility Gradient Intra-voxel static dephasing (DT2*) Contrast Agent Particles Blood Vessel Figure from Cerebral MR Perfusion. Sorensen and Reimer Intra-voxel Incoherent motion (DT2)

  11. Intra-voxel Spin Motion Random or very Intelligently Designed??

  12. Signal loss depends on vessel size and type of scan Spin-echo sequences are more selective for small vessels because diffusion effects dominate for smaller vessels. Figure from Cerebral MR Perfusion. Sorensen and Reimer Voxel close to large vessel sees little field variation voxel close to small vessel sees large field variation

  13. Change in MRI signal due to passage of contrast agent Figure from Cerebral MR Perfusion. Sorensen and Reimer • Arrival time • Maximum contrast concentration • Full-width at half maximum • Pre-injection baseline • Contrast arrival • Peak signal change • Recirculation • Post-injection baseline

  14. Conversion of signal-vs-time to concentration-vs-time C(t) = -k/TE ln(s(t)/so) Figure from Cerebral MR Perfusion. Sorensen and Reimer

  15. Indicator Dilution Theory Assume a known amount of tracer is injected in a volume and flow is constant. The flow can be measured by monitoring the concentration, C(t), at the output of the volume. Flow = A / C(t) dt where A is total amount of agent injected. Tracer in Tracer out Figure from Cerebral MR Perfusion. Sorensen and Reimer

  16. Indicator Dilution Theory Units: A, mmol C(t), mmol/ml F, ml/sec C(t) Dt A = C(Dt) F Dt + C(2Dt) F Dt + …. C(nDt) F Dt + … A = F C(t) dt or F = A / C(t) dt

  17. Differences in Dynamic Contrast MRI • don’t know how much goes into each voxel • the injection is not instantaneous • don’t monitor concentration at output • flow may not be uniform in voxel

  18. Indicator Dilution Theory Applied to DC-MRI CA(t), Arterial Input Function Units: CV, mmol/gm CA (t), mmol/ml F, ml/gm/sec Dt CV ( Dt) = CA( Dt) R1 F Dt CV (2Dt) = CA(2Dt) R1 F Dt + CA (Dt) R2 F Dt … CV (nDt) = CA(nDt) R1 F Dt + … CA(Dt) Rn F Dt Rn, Fraction of contrast agent remaining in the tissue VOI where R1 = 1.

  19. Indicator Dilution Theory Applied to DC-MRI CV ( Dt) CV (2Dt) CV (3Dt) … CV (nDt) CA( Dt) CA(2Dt) CA( Dt) CA(3Dt) CA(2Dt) CA( Dt) CA(4Dt) CA(3Dt) CA( 2Dt) … CA(nDt) CA((n-1)Dt) … CA( Dt) R1 R2 R3 … Rn 0 F = CV = F CA R Solve for FR. F = max of FR. V = F S R

  20. CV = F CA R. How to solve for FR? One method: Get pseudo-inverse of CA. SVD truncation threshold can be set arbitrarily or by optimizing ‘goodness’ parameters.

  21. B: SVD Threshold = 0.050 A B C A: SVD Threshold = 0.015 C: SVD Threshold = 0.200

  22. Getting an Arterial Input Function MCA MCA Pre-injection scan Post-injection – at peak signal change

  23. Getting an Arterial Input Function Very difficult to get a curve that truly represents the concentration of the contrast agent in the vessel. This is a major factor in limiting the ability to absolute perfusion measures.

  24. Other Issues for Quantitative Perfusion Even if a good concentration curve can be obtained, the arterial input function measured at the large artery does not represent the true arterial input to the voxel. There is possibly delay and dispersion of the AIF. Obtaining absolute quantitative perfusion measures requires knowledge of a number of physiological parameters that can not be determined with great accuracy.

More Related