Nuclear Medicine Image (NM) Integration Profile

Nuclear Medicine Image (NM) Integration Profile. Kevin O’Donnell IHE Radiology Technical Committee Member, Toshiba Medical Systems Company. NM – Actors and Transactions. Points of Interest - NM. Appendix E, Volume 1 (Informative) New to Nuclear Medicine?

Download Presentation

Nuclear Medicine Image (NM) Integration Profile

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nuclear Medicine Image (NM)Integration Profile Kevin O’Donnell IHE Radiology Technical Committee Member, Toshiba Medical Systems Company Radiology Participant Workshop, Oct 2004

  2. NM – Actors and Transactions Radiology Participant Workshop, Oct 2004

  3. Points of Interest - NM • Appendix E, Volume 1 (Informative) • New to Nuclear Medicine? • Trouble matching NM to Scheduled Workflow? • Start Here. • E.2 NM Workflow – What happens in NM procedures • E.3 NM Worklists – How to schedule/model it • E.4 NM Data – What to expect in the DICOM • E.5 NM Display – How it should be presented • Many subtleties here Radiology Participant Workshop, Oct 2004

  4. Points of Interest – Acquisition Modality • Acquisition Modality • Modality Images Stored [8] • Create NM objects as specified • additional attribute & vector handling • e.g. Cardiac context codes, slice spacing, patient orientation • Study & Series UID creation clarification • e.g. After PPS complete, new images MUST be new series • e.g. Reconstructed images MUST be new series Radiology Participant Workshop, Oct 2004

  5. Points of Interest –Image Manager/Archive • Image Manager/Archive • Store/Retrieve NM Objects • Store/Retrieve Secondary Capture Objects • Refer to list in the spec. • “Level 2” storage requirement clarification • e.g. keep private tags • Support for Series Description as Query matching/return key Radiology Participant Workshop, Oct 2004

  6. Points of Interest – Evidence Creator • Evidence Creator • Creator Images Stored [18] • Ditto. (i.e. See Acquisition Modality) • Result Screen Export Option Radiology Participant Workshop, Oct 2004

  7. Result Screen Export Option:Evidence Creators • Render Dynamic Result Screens • Based on the following DICOM Objects: • Multi-Frame Grayscale Byte Secondary Capture • Multi-Frame True Color Secondary Capture • Creating multiple single frame objects is NOT sufficient. • Render Static Result Screens • Using single frame DICOM Secondary Captures is sufficient • Using Multi-frame to render single or several related static result screens is recommended • provides better image comment/label attributes • provides implicit display order • displayed by stepping, not cine • Must generate appropriate Secondary Capture objects from any Result Screens created. Radiology Participant Workshop, Oct 2004

  8. Example Result Screen Radiology Participant Workshop, Oct 2004

  9. Points of Interest – Image Display • Image Display • Retrieve Images [16] • Display NM and Result-Screen Images • Note requirement for Color, Greyscale, Static & Dynamic Secondary Capture • Support specified NM essential display capabilities • Additional attribute handling • e.g. Patient State, Image Orientation, Detector Sequence, View Code Sequence • Review Option Radiology Participant Workshop, Oct 2004

  10. Points of Interest – Image Display • Handle multi-frame / multi-vector images • Multiple simultaneous cines • Grayscale and color result screens • Dynamic and static result screens • Original resolution and scaled • Separate adjustment of upper and lower window levels • Apply local color tables to grayscale screens • Add new local color tables to system • Change intensity of grayscale result screens (recommended) • Display Series Description tag • …, etc. Radiology Participant Workshop, Oct 2004

  11. Points of Interest – Image Display • Scale “intelligently” to avoid presenting postage-stamp size NM images • Allow user to select different vectors/framesets of complex multi-frame images • Allow user to separately adjust intensity for different framesets (eg, phases) in the same “image” Radiology Participant Workshop, Oct 2004

  12. Display Formats • Grid display • Frames from one image set • Comparison display • Compare frames from multiple image sets • Fit display • Frames from multiple image sets Radiology Participant Workshop, Oct 2004

  13. Review Option: Image Displays • Adds Image Display requirements to support Review of NM Images • MPR Display • More series at once • Different series types together • Pixel value display • More reason to review Appendix E in detail Radiology Participant Workshop, Oct 2004