An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Biosensors: Development and Environmental Testing Investigators: Anne J. Anderson, Charles D. Miller and Joan E. McLean Utah State University Logan, Utah 84322-5305 RD-83090701-0

  2. Metals of interest Copper:maximum drinking water level standard 1.3 mg/L aquatic chronic exposure limit 30.3 µg/L Human tolerance relatively high Used for microbial pest control Some lower organisms acute toxicity (phytoplankton, zooplankton, amphibians) Cadmium:maximum drinking water standard 0.005 mg/L aquatic chronic exposure limit 2.7µg/L Higher animal toxicity: accumulates in kidneys and liver, produces bone and blood problems Carcinogenic (Group B1) Minor use as pesticide

  3. Cu is a trace element: required for certain enzymatic and carrier proteins Cd no known cellular use—toxic- may disrupt Ca and Zn metabolism Both cause oxidative stress Both act on –SH proteins Cell concentrations regulated by chelation, sorption, uptake, and efflux mechanisms MX

  4. Biosensors • Final goals: • An array of promoter fusions that respond differentially and specifically • with light output upon exposure to toxic metals • 2) A gene chip array to detect transcript abundance from cells responding to • toxic metals. Pattern of gene activation would specify the metal.

  5. Test organisms: P. putida strains Cells of both pseudomonads are killed by concentrations of Cu starting between 1 and 10 mg/L

  6. P. putida KT2440 1000000000 100000000 10000000 1000000 100000 1 h 1 h # cells per 1 ml 4 h 4 h 10000 1000 100 10 1 0.001 0.01 0.1 1 10 100 mg/L of Cd2+ P. putida Corvallis 100000000 10000000 1000000 100000 10000 # cells per 1 ml 1000 100 10 1 0.001 0.01 0.1 1 10 100 mg/L of Cd2+ The pseudomonad cells show little change in culturability with Cd even at doses of 100 mg/L. Both wild type isolates behave similarly showing resistance to Cd

  7. Generation of Luciferase Biosensor Metal stimulus Wild type lux A/B promoter ORF Transcript Transcript Light Protein product Normal cell Biosensor

  8. P. putida Corvallis mutants-Cu [in .01M CaCl2] 30 25 20 Cat A*10 Lux Bfr 15 FeSOD 10 5 0 0 0.01 0.1 1 10 mg/L of Cu2+

  9. P. putida Corvallis mutants-Cd [in .01M KNO ] 3 14 12 10 Cat A*10 8 Lux Bfr 6 FeSOD 4 2 0 0 1 10 50 100 mg/L of Cd2+ Corvallis mutants-Cd P. putida Cadmium detection [in .01M Ca(NO3)2] 14 Cat A*10 12 Bfr 10 FeSOD 8 Lux 6 4 2 0 0 1 10 50 100 mg/L Cd2+ FeSOD mutant is most sensitive Ca inhibits the Cd response

  10. Response of KT2440 mutants to Cu 3.5 3 2.5 2 10 mg/L Relative change in lux (fold) 1 mg/L 1.5 1 0.5 0 68 18 45 47 41 4 43 66 70 69 7 31 46 21 3 30 Mutant strain

  11. Response of KT2440 mutants to Cd 16 14 12 10 100 mg/L 10 mg/L 8 Relative change in lux (fold) 1 mg/L 6 4 2 0 54 18 31 30 43 4 68 46 45 69 7 70 21 41 3 47 45 Mutant strain

  12. pI 4 pI 7 pI 4 pI7

  13. Spot B: increased three fold Corresponded to lipoamide dehydrogenase in TCA cycle

  14. pI 4 pI 7 4-15% Mr (kDa) Cd responses 97.0 66.0 45.0 30.0 20.1 14.4 Peptides of increased Intensity. KT2440 0.01M Ca(NO3)2 100 ppm Cd

  15. Conclusions • The two approaches for biosensor development are feasible • 2) luxAB::Insertional mutants that detect Cu and Cd differentially have • been identified • Gene loci await determination • 3) Peptides that increase upon Cu exposure are detected and one has been • correlated with a specific function RD-83090701-0