1 / 12

Design and Construction of an Induction Furnace (Cooling System)

Design and Construction of an Induction Furnace (Cooling System). Presented By Mg Thant Zin Win Roll No: Ph.D-M-7 2 nd Seminar 16.6.2004. Review on 1 st Seminar. Classification of Furnace Basic Principle of Induction Heating Induction Furnace Coils and Water Piping System.

dalit
Download Presentation

Design and Construction of an Induction Furnace (Cooling System)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design and Construction of an Induction Furnace(Cooling System) Presented By Mg Thant Zin Win Roll No: Ph.D-M-7 2nd Seminar 16.6.2004

  2. Review on 1st Seminar • Classification of Furnace • Basic Principle of Induction Heating • Induction Furnace Coils and Water Piping System

  3. Four Parts Divided in 2nd Seminar • Objective • Types of Cooling Water System • Selection of System • Conclusion

  4. Objective • To consider and select the suitable water cooling system among the various forms of water cooling plants for a coreless induction furnace

  5. Types of Cooling Water System • Open-circuit system with evaporative cooling-tower • Fan-radiator (closed-circuit) system • Dual system with Water/Water heat exchanger • Dual system with closed-circuit cooling-tower

  6. 1.Open-circuits System with Evaporative Cooling-tower • Advantages • Simplicity • Low capital cost • Disadvantages • Water is lost by evaporation. • Airborne dust and impurities are drawn into the tower.

  7. 2.Fan-raditor (Closed-circuit) System • Advantages • Water circuit can be made completely enclose. • Loss of water is slight. • Disadvantages • Radiators are large for a given thermal duty. • Radiator fins are subject to blockage by atmospheric dust, and may be difficulty to clean.

  8. 3.Dual System with Water/Water Heat Exchanger • Advantages • The water/water heat exchanger is more compact and easier to clean and maintain than the fan-radiator system. • Disadvantages • A primary source of cooling water is required.

  9. 4.Dual System with Closed-circuit Cooling-tower • Advantages • Water/water heat exchanger is eliminated. • Piping and pumping costs are lower than in conventional tower with heat exchanger. • Disadvantages • Slightly more expansive than conventional tower with heat exchanger.

  10. Selection of System • Furnace size • Furnace environment • Local water Board regulation • Nature of water supply available • Local noise-control requirements-particularly at night • Cost

  11. Conclusion • Open-circuit system with evaporative cooling-tower • Fan-radiator (closed-circuit) system • Dual system with Water/Water heat exchanger • Dual system with closed-circuit cooling-tower • What do you choose the water cooling system to construct a Coreless Induction Furnace?

  12. THANK YOU