170 likes | 277 Views
Advisor Advanced. Release FW120. Overview. Start up wizard - update Remote user code Zone open too long notification – related to access Keypad E/E counter displayed Inverted Walk Test PIN of the day Service Req message after certain Interval Demo Mode
E N D
Advisor Advanced Release FW120
Overview • Start up wizard - update • Remote user code • Zone open too long notification – related to access • Keypad E/E counter displayed • Inverted Walk Test • PIN of the day • Service Req message after certain Interval • Demo Mode • User code entry without pressing ENTER • Option to disable all faults on keypad • Walk Test with reporting • Walk Test with arming the system • Walk Test per zone • MMS functionality
Start up wizard - update Installation 76% 1. Panel language 2. Defaults 3. Time & date 4. Variant 5. Install
Zone open too long notification – related to access Door Access with Badge, if door is open too long it can activate the output on the reader to beep until the door is closed.
Demo Mode Active for 15 min Displays “Demo Mode” on every keypad
User code entry without pressing ENTER -> Use 1122 to disarm -> cannot be used with Door access 1122 + F
Option to disable all faults on keypad • Selection: • Always • On Set • Disable all Faults
Walk test with reporting Features The panel supports system walk test whereby all triggered sensors will be reported to the monitoring station, but no siren shall be activated. Start Walk test with Reporting To start walk test with reporting : 1>Service menu 2>test menu 5> Walk test menu 1>Start Then the installer can choose between with or without reporting. • Walktest all zones (only keypad/internal sounder beep) • Walktest all zones with reporting including the keypad/internal sounder beep
Walk test with arming the system Features The panel supports system walk test whereby the system is armed via the user interface and alarms created by triggering all sensors. All sensor alarms will be reported to the monitoring station, but no siren shall be activated. Activate Walk test with arming the system To activate Walk Test with arming the system : 1>Service menu 2>test menu 5> Walk test menu 4>Walktest Mode Walk test scenario is based on a standard use case -> arming the system -> tripping zones -> disarming. Test ends when the Installer turns off the WT Mode in the menu, or the timer expires. This is to prevent the unwanted remaining in the WT Mode.
Walk test per zone Features The Walk test per zone is a functionality for the installers who want to verify a single zone instead of having to run a walk test for all zones. Activate Walk Test per zone • To start Walk Test per zon : 1>Service menu 2>test menu 5> Walk test menu • 3>SingleZone WT • The installer can choose between with or without reporting. Functionality similar to the general walk test option.
MMS Features Possibility to send pictures taken by a PirCam to cell phones using MMS. Configuration MMS Configuration of the MMS functionality: Central Station settings: MMS Settings (Path Options GSM) : (Settings MMS Center Belgium)